Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-7533

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-01 Dec, 2020 | 14:47
Updated At-10 Jun, 2025 | 08:02
Rejected At-
Credits

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:01 Dec, 2020 | 14:47
Updated At:10 Jun, 2025 | 08:02
Rejected At:
▼CVE Numbering Authority (CNA)

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.

Affected Products
Vendor
n/a
Product
Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see security notification for version information)
Default Status
unaffected
Versions
Affected
  • Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see security notification for version information)
Problem Types
TypeCWE IDDescription
CWECWE-287CWE-287 Improper Authentication
Type: CWE
CWE ID: CWE-287
Description: CWE-287 Improper Authentication
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_File_Name=SEVD-2020-287-01_Modicon_Web_Server_Security_Notificatiton.pdf&p_Doc_Ref=SEVD-2020-287-01&p_enDocType=Security+and+Safety+Notice
N/A
Hyperlink: https://download.schneider-electric.com/files?p_File_Name=SEVD-2020-287-01_Modicon_Web_Server_Security_Notificatiton.pdf&p_Doc_Ref=SEVD-2020-287-01&p_enDocType=Security+and+Safety+Notice
Resource: N/A
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-287-01/
x_refsource_MISC
x_transferred
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-287-01/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:01 Dec, 2020 | 15:15
Updated At:10 Jun, 2025 | 08:15

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302_firmware>>Versions before 3.20(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342000_firmware>>Versions before 3.20(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342000>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp342000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp341000_firmware>>Versions before 3.20(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp341000>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102_firmware>>Versions before 3.20(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302_firmware>>Versions before 3.20(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0100_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0100>>-
cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0110_firmware>>Versions before 6.5(exclusive)
cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0110>>-
cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoc0401_firmware>>Versions before 2.10(exclusive)
cpe:2.3:o:schneider-electric:bmxnoc0401_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoc0401>>-
cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp574634_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:tsxp574634_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp574634>>-
cpe:2.3:h:schneider-electric:tsxp574634:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp575634_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:tsxp575634_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp575634>>-
cpe:2.3:h:schneider-electric:tsxp575634:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp576634_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:tsxp576634_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp576634>>-
cpe:2.3:h:schneider-electric:tsxp576634:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety4103_firmware>>Versions before 6.2(exclusive)
cpe:2.3:o:schneider-electric:tsxety4103_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety4103>>-
cpe:2.3:h:schneider-electric:tsxety4103:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety5103_firmware>>Versions before 6.4(exclusive)
cpe:2.3:o:schneider-electric:tsxety5103_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety5103>>-
cpe:2.3:h:schneider-electric:tsxety5103:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noe77111_firmware>>Versions before 7.1(exclusive)
cpe:2.3:o:schneider-electric:140noe77111_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noe77111>>-
cpe:2.3:h:schneider-electric:140noe77111:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc78000_firmware>>Versions before 1.74(exclusive)
cpe:2.3:o:schneider-electric:140noc78000_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc78000>>-
cpe:2.3:h:schneider-electric:140noc78000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc77101_firmware>>Versions before 1.08(exclusive)
cpe:2.3:o:schneider-electric:140noc77101_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc77101>>-
cpe:2.3:h:schneider-electric:140noc77101:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65260_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:140cpu65260_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65260>>-
cpe:2.3:h:schneider-electric:140cpu65260:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-287Primarycybersecurity@se.com
NVD-CWE-noinfoSecondarynvd@nist.gov
CWE ID: CWE-287
Type: Primary
Source: cybersecurity@se.com
CWE ID: NVD-CWE-noinfo
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_File_Name=SEVD-2020-287-01_Modicon_Web_Server_Security_Notificatiton.pdf&p_Doc_Ref=SEVD-2020-287-01&p_enDocType=Security+and+Safety+Noticecybersecurity@se.com
N/A
https://www.se.com/ww/en/download/document/SEVD-2020-287-01/af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_File_Name=SEVD-2020-287-01_Modicon_Web_Server_Security_Notificatiton.pdf&p_Doc_Ref=SEVD-2020-287-01&p_enDocType=Security+and+Safety+Notice
Source: cybersecurity@se.com
Resource: N/A
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-287-01/
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1258Records found

CVE-2014-9200
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-1.47% / 80.11%
||
7 Day CHG~0.00%
Published-01 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-unity_prosomovesomove_litesomachinen/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-25176
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.1||CRITICAL
EPSS-2.61% / 85.08%
||
7 Day CHG~0.00%
Published-18 Mar, 2022 | 18:00
Updated-16 Apr, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal

Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.

Action-Not Available
Vendor-xylemRockwell Automation, Inc.
Product-micro850saitel_dpmultismart_firmwareisagraf_runtimeeasergy_t300epas_gtwmicro820pacis_gtw_firmwaremicro830micro830_firmwaremicro870_firmwaremicro820_firmwaremicro870easergy_c5_firmwaresaitel_drmicro850_firmwarepacis_gtwsaitel_dr_firmwarecp-3saitel_dp_firmwareisagraf_free_runtimeepas_gtw_firmwareeasergy_c5micom_c264mc-31aadvance_controllermicom_c264_firmwarescd2200_firmwareeasergy_t300_firmwaremicro810micro810_firmwareISaGRAF Runtime
CWE ID-CWE-23
Relative Path Traversal
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-26507
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.70% / 90.86%
||
7 Day CHG~0.00%
Published-14 Apr, 2022 | 12:04
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-attn/a
Product-ecostruxure_process_expertecostruxure_control_expertremoteconnectxmillscadapack_470scadapack_570scadapack_574scadapack_575scadapack_474n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-24311
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.70% / 87.48%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-24324
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.32% / 84.15%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-24312
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.75% / 81.80%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-2329
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.09% / 86.26%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-24313
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.71% / 88.94%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-24310
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.64% / 81.20%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-22805
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-8.20% / 91.85%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-scl_series_1036_upssmc_series_1018_ups_firmwaresmtl_series_1026_upsscl_series_1029_ups_firmwaresmt_series_1015_upssmtl_series_1026_ups_firmwarescl_series_1030_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_ups_firmwaresmx_series_1031_upsscl_series_1037_ups_firmwarescl_series_1037_upsscl_series_1036_ups_firmwaresmc_series_1018_upsscl_series_1030_upsscl_series_1029_upsSmartConnect
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2017-9629
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-19.42% / 95.16%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2017-5155
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.3||HIGH
EPSS-0.64% / 69.66%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_historianSchneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2022-22806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.30%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-scl_series_1036_upssmc_series_1018_ups_firmwaresmtl_series_1026_upsscl_series_1029_ups_firmwaresmt_series_1015_upssmtl_series_1026_ups_firmwarescl_series_1030_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_ups_firmwaresmx_series_1031_upsscl_series_1037_ups_firmwarescl_series_1037_upsscl_series_1036_ups_firmwaresmc_series_1018_upsscl_series_1030_upsscl_series_1029_upsSmartConnect
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-22813
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.41% / 60.36%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.

Action-Not Available
Vendor-n/a
Product-easergy_p746_firmwareeasergy_p742easergy_p849easergy_p441easergy_p142_firmwareeasergy_p546easergy_p543easergy_p541easergy_p143_firmwareeasergy_p141easergy_p342easergy_p542easergy_p241_firmwareeasergy_p545_firmwareeasergy_p243_firmwareeasergy_p446easergy_p741easergy_p642easergy_p541_firmwareeasergy_p342_firmwareeasergy_p645easergy_p345_firmwareeasergy_p743easergy_p145easergy_p343_firmwareeasergy_p849_firmwareeasergy_p643_firmwareeasergy_p242_firmwareeasergy_p545easergy_p344easergy_p142easergy_p442easergy_p544easergy_p143easergy_p441_firmwareeasergy_p743_firmwareeasergy_p542_firmwareeasergy_p645_firmwareeasergy_p242easergy_p841easergy_p343easergy_p543_firmwareeasergy_p443_firmwareeasergy_p446_firmwareeasergy_p445_firmwareeasergy_p341_firmwareeasergy_p742_firmwareeasergy_p444_firmwareeasergy_p445easergy_p444easergy_p642_firmwareeasergy_p341easergy_p544_firmwareeasergy_p442_firmwareeasergy_p741_firmwareeasergy_p141_firmwareeasergy_p841_firmwareeasergy_p241easergy_p344_firmwareeasergy_p746easergy_p643easergy_p546_firmwareeasergy_p145_firmwareeasergy_p443easergy_p345easergy_p243Easergy P40 Series model numbers with Ethernet option bit as Q, R, S (All PX4X firmware Versions)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2020-7548
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.59% / 68.26%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.

Action-Not Available
Vendor-n/a
Product-acti9_powertag_linkacti9_smartlink_el_bacti9_smartlink_si_d_firmwareacti9_smartlink_si_b_firmwarewiser_link_firmwarewiser_linkacti9_powertag_link_hdwiser_energywiser_energy_firmwareacti9_smartlink_si_dacti9_powertag_link_firmwareacti9_powertag_link_hd_firmwareacti9_smartlink_si_bacti9_smartlink_el_b_firmwareSmartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)
CWE ID-CWE-330
Use of Insufficiently Random Values
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.38% / 58.48%
||
7 Day CHG+0.16%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-0223
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.23% / 45.67%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-6840
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.50% / 65.10%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:19
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed.

Action-Not Available
Vendor-
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0002meg6501-0001_firmwaremeg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Server
CWE ID-CWE-134
Use of Externally-Controlled Format String
CVE-2019-6824
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-13.84% / 94.04%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:44
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2019-6823
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-15.51% / 94.40%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:41
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-6808
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.84% / 87.70%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:05
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2015-0982
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-2.56% / 84.92%
||
7 Day CHG~0.00%
Published-14 Mar, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-pelco_ds-nvn/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-22795
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-3.19% / 86.47%
||
7 Day CHG~0.00%
Published-28 Mar, 2022 | 16:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-22767
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.59% / 68.18%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276

Action-Not Available
Vendor-n/a
Product-powerlogic_egx300_firmwarepowerlogic_egx100powerlogic_egx100_firmwarepowerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22714
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.27% / 83.98%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:13
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion9000_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion9000powerlogic_ion7400_firmwarepowerlogic_ion7400PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22707
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-90.00% / 99.56%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2020-7475
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 67.65%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 18:56
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertmodicon_m580_firmwareunity_promodicon_m340modicon_m340_firmwaremodicon_m580EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.81%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7540
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.31% / 53.67%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwarebmxnor200h_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnor200htsxp576634_firmwarebmxnoc0401modicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-32515
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.16% / 36.92%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-conext_comboxconext_combox_firmwareConext™ ComBox
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2021-22764
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.33% / 55.23%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-24 Nov, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.

Action-Not Available
Vendor-n/a
Product-powerlogic_pm5561powerlogic_pm5560_firmwarepowerlogic_pm5562_firmwarepowerlogic_pm5561_firmwarepowerlogic_pm5563powerlogic_pm5563_firmwarepowerlogic_pm5562powerlogic_pm5560PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)
CWE ID-CWE-287
Improper Authentication
CVE-2018-7227
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 40.37%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-287
Improper Authentication
CVE-2018-7236
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.1||HIGH
EPSS-0.25% / 47.88%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 20:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-287
Improper Authentication
CVE-2023-25556
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.3||HIGH
EPSS-0.12% / 32.23%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 17:03
Updated-05 Feb, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.

Action-Not Available
Vendor-Schneider Electric SE
Product-merten_instabus_tastermodul_2fach_system_mmerten_instabus_tastermodul_1fach_system_mmerten_tasterschnittstelle_4fach_plus_firmwaremerten_instabus_tastermodul_2fach_system_m_firmwaremerten_knx_uni-dimmaktor_ll_reg-k\/2x230\/300_wmerten_jalousie-\/schaltaktor_reg-k\/8x\/16x\/10_m._hbmerten_instabus_tastermodul_1fach_system_m_firmwaremerten_knx_argus_180\/2\,20m_up_systemmerten_knx_schaltakt.2x6a_up_m.2_eing._firmwaremerten_tasterschnittstelle_4fach_plusmerten_knx_argus_180\/2\,20m_up_system_firmwaremerten_jalousie-\/schaltaktor_reg-k\/8x\/16x\/10_m._hb_firmwaremerten_knx_schaltakt.2x6a_up_m.2_eing.merten_knx_uni-dimmaktor_ll_reg-k\/2x230\/300_w_firmwareMerten INSTABUS Tastermodul 1fach System M 625199Merten KNX Uni-Dimmaktor LL REG-K/2x230/300 W MEG6710-0002Merten INSTABUS Tastermodul 2fach System M 625299Merten KNX Schaltakt.2x6A UP m.2 Eing. MEG6003-0002Merten KNX ARGUS 180/2,20M UP SYSTEM 631725Merten Tasterschnittstelle 4fach plus 670804Merten Jalousie-/Schaltaktor REG-K/8x/16x/10 m. HB 649908
CWE ID-CWE-287
Improper Authentication
CVE-2011-4860
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-1.58% / 80.85%
||
7 Day CHG~0.00%
Published-17 Dec, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a (1) ARP request message or (2) Neighbor Solicitation message.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-quantum_ethernet_module_140noe77101quantum_ethernet_module_140noe77100quantum_ethernet_module_140noe77111n/a
CWE ID-CWE-287
Improper Authentication
CVE-2022-0715
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-1.25% / 78.46%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-02 Aug, 2024 | 23:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-smt_series_1015_upssmtl_series_1026_ups_firmwaresrt_series_1021_ups_firmwaresrt_series_1013_ups_firmwaresrtl2200rmxli-ncsrtl1500rmxli-nc_firmwaresrt_series_1010_ups_firmwaresmc_series_1007_upssrt_series_1014_ups_firmwaresmc_series_1041_ups_firmwaresmc_series_1007_ups_firmwaresmx_series_20_upssrtl1000rmxlismc_series_1041_upssmc_series_1005_ups_firmwaresrtl2200rmxlisrtl3000rmxli-ncsrt_series_1001_ups_firmwaresrtl2200rmxli-nc_firmwaresrt_series_1001_upsscl_series_1030_ups_firmwaresrtl3000rmxli_firmwaresmt_series_1031_upssrt_series_1020_upsscl_series_1036_ups_firmwaresmt_series_1040_upssmc_series_1018_upssrt_series_1010_upsscl_series_1030_upssrtl1000rmxli-ncsmtl_series_1026_upsscl_series_1029_ups_firmwaresrtl1000rmxli_firmwaresrt_series_1020_ups_firmwaresmt_series_1040_ups_firmwaresrtl1000rmxli-nc_firmwaresrtl1500rmxlisrtl3000rmxlisrtl3000rmxli-nc_firmwaresrt_series_1021_upssrt_series_1014_upssrtl1500rmxli-ncsmt_series_1031_ups_firmwarescl_series_1036_upssmc_series_1018_ups_firmwaresmx_series_23_upssrtl1500rmxli_firmwaresrt_series_1002_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_upssmx_series_1031_ups_firmwaresrt_series_1019_ups_firmwaresrt_series_1002_upssmx_series_20_ups_firmwarescl_series_1037_ups_firmwaresrt_series_1019_upssrt_series_1025_ups_firmwaresrt_series_1013_upsscl_series_1037_upssrtl2200rmxli_firmwaresmt_series_18_ups_firmwaresrt_series_1025_upssmc_series_1005_upssmt_series_18_upssmx_series_23_ups_firmwarescl_series_1029_upsSmartConnect APC Smart-UPS
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2019-6832
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.3||HIGH
EPSS-0.14% / 34.96%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:31
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.

Action-Not Available
Vendor-
Product-wiser_for_knx_firmwarespacelynk_firmwarelss100100lss100200spaceLYnkWiser for KNX
CWE ID-CWE-287
Improper Authentication
CVE-2019-6854
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.03% / 6.05%
||
7 Day CHG~0.00%
Published-06 Jan, 2020 | 22:56
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017.

Action-Not Available
Vendor-n/a
Product-clearscadaEcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)
CWE ID-CWE-287
Improper Authentication
CVE-2021-22796
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.63% / 69.41%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)

Action-Not Available
Vendor-n/a
Product-c-gate_serverC-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
CWE ID-CWE-287
Improper Authentication
CVE-2024-57049
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-30.08% / 96.50%
||
7 Day CHG+5.59%
Published-18 Feb, 2025 | 00:00
Updated-06 Jun, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the TP-Link Archer c20 router with firmware version V6.6_230412 and earlier permits unauthorized individuals to bypass the authentication of some interfaces under the /cgi directory. When adding Referer: http://tplinkwifi.net to the the request, it will be recognized as passing the authentication.

Action-Not Available
Vendor-n/aTP-Link Systems Inc.
Product-archer_c20archer_c20_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-6117
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-89.20% / 99.52%
||
7 Day CHG~0.00%
Published-11 Jul, 2014 | 19:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dahua DVR 2.608.0000.0 and 2.608.GV00.0 allows remote attackers to bypass authentication and obtain sensitive information including user credentials, change user passwords, clear log files, and perform other actions via a request to TCP port 37777.

Action-Not Available
Vendor-n/aDahua Technology Co., Ltd
Product-dvr_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2024-56336
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-9.5||CRITICAL
EPSS-0.10% / 27.90%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-11 Mar, 2025 | 14:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured.

Action-Not Available
Vendor-Siemens AG
Product-SINAMICS S200
CWE ID-CWE-287
Improper Authentication
CVE-2013-4824
Matching Score-4
Assigner-HP Inc.
ShareView Details
Matching Score-4
Assigner-HP Inc.
CVSS Score-7.5||HIGH
EPSS-77.70% / 98.95%
||
7 Day CHG~0.00%
Published-13 Oct, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unspecified vulnerability in HP Intelligent Management Center (iMC) and HP IMC Service Operation Management Software Module allows remote attackers to bypass authentication via unknown vectors, aka ZDI-CAN-1644.

Action-Not Available
Vendor-n/aHP Inc.
Product-imc_service_operation_management_software_moduleintelligent_management_centern/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-7921
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||CRITICAL
EPSS-94.14% / 99.90%
||
7 Day CHG~0.00%
Published-06 May, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Authentication issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The improper authentication vulnerability occurs when an application does not adequately or correctly authenticate users. This may allow a malicious user to escalate his or her privileges on the system and gain access to sensitive information.

Action-Not Available
Vendor-n/aHIKVISION
Product-ds-2cd4212fwd-i\(z\)ds-2cd2332-ids-2cd2512f-i\(s\)_firmwareds-2cd4332fwd-i\(z\)ds-2dfx_series_firmwareds-2cd4132fwd-i\(z\)_firmwareds-2cd2t32-i8_firmwareds-2cd2032-ids-2cd4212f-i\(s\)ds-2cd2132-i_firmwareds-2cd2712f-i\(s\)_firmwareds-2cd2212-i5_firmwareds-2cd2612f-i\(s\)ds-2cd2t32-i3ds-2cd4024f-\(p\)ds-2cd4024f-\(w\)ds-2cd4224f-i\(z\)_firmwareds-2cd4012fwd-\(w\)ds-2cd2032-i_firmwareds-2cd4212f-i\(h\)_firmwareds-2cd4324f-i\(s\)_firmwareds-2cd4332fwd-i\(s\)_firmwareds-2cd2t32-i5_firmwareds-2cd4212f-i\(h\)ds-2cd4024f-\(w\)_firmwareds-2cd4112f-i\(z\)_firmwareds-2cd4012fwd-\(a\)ds-2cd4132fwd-i\(z\)ds-2cd2312-ids-2cd4124f-i\(z\)ds-2cd4332fwd-i\(s\)ds-2cd4232fwd-i\(h\)ds-2cd4332fwd-i\(z\)_firmwareds-2cd4312f-i\(z\)_firmwareds-2cd4332fwd-i\(h\)ds-2cd2432f-i\(w\)_firmwareds-2cd2t32-i8ds-2cd63xx_seriesds-2cd4324f-i\(z\)_firmwareds-2cd4212f-i\(z\)_firmwareds-2cd4112fwd-i\(z\)ds-2cd4312f-i\(h\)ds-2cd4012f-\(p\)_firmwareds-2cd2632f-i\(s\)_firmwareds-2cd2612f-i\(s\)_firmwareds-2cd63xx_series_firmwareds-2cd2t32-i3_firmwareds-2cd4032fwd-\(a\)_firmwareds-2cd4112fwd-i\(z\)_firmwareds-2cd2112-ids-2cd4232fwd-i\(z\)ds-2cd2112-i_firmwareds-2cd6412fwd_firmwareds-2cd2712f-i\(s\)ds-2cd4212fwd-i\(s\)ds-2cd4332fwd-i\(h\)_firmwareds-2cd4232fwd-i\(s\)_firmwareds-2cd4224f-i\(s\)_firmwareds-2cd4212fwd-i\(z\)_firmwareds-2cd4012f-\(a\)ds-2cd4012fwd-\(a\)_firmwareds-2cd2412f-i\(w\)_firmwareds-2cd2332-i_firmwareds-2cd4312f-i\(z\)ds-2cd4312f-i\(s\)_firmwareds-2cd4324f-i\(h\)_firmwareds-2cd4012fwd-\(w\)_firmwareds-2cd2512f-i\(s\)ds-2cd4024f-\(a\)_firmwareds-2cd4312f-i\(h\)_firmwareds-2cd4032fwd-\(p\)ds-2cd4212f-i\(s\)_firmwareds-2cd4324f-i\(s\)ds-2cd2312-i_firmwareds-2cd2232-i5_firmwareds-2cd4232fwd-i\(z\)_firmwareds-2cd2132-ids-2cd4032fwd-\(w\)_firmwareds-2cd4012f-\(w\)ds-2cd4032fwd-\(w\)ds-2cd4212f-i\(z\)ds-2cd4224f-i\(h\)ds-2cd4012f-\(w\)_firmwareds-2cd4224f-i\(z\)ds-2cd6412fwdds-2cd2532f-i\(s\)_firmwareds-2cd4212fwd-i\(h\)ds-2cd4324f-i\(h\)ds-2cd4012fwd-\(p\)ds-2cd2632f-i\(s\)ds-2cd4312f-i\(s\)ds-2cd2232-i5ds-2cd2412f-i\(w\)ds-2cd4232fwd-i\(s\)ds-2cd2t32-i5ds-2cd4112f-i\(z\)ds-2cd4212fwd-i\(h\)_firmwareds-2cd2732f-i\(s\)ds-2cd2432f-i\(w\)ds-2cd4032fwd-\(a\)ds-2cd4012fwd-\(p\)_firmwareds-2cd4024f-\(p\)_firmwareds-2cd4012f-\(p\)ds-2cd4012f-\(a\)_firmwareds-2cd2732f-i\(s\)_firmwareds-2cd4224f-i\(s\)ds-2cd4124f-i\(z\)_firmwareds-2cd4224f-i\(h\)_firmwareds-2cd4212fwd-i\(s\)_firmwareds-2cd2532f-i\(s\)ds-2cd4024f-\(a\)ds-2dfx_seriesds-2cd4032fwd-\(p\)_firmwareds-2cd4232fwd-i\(h\)_firmwareds-2cd2212-i5ds-2cd4324f-i\(z\)Hikvision Cameras
CWE ID-CWE-287
Improper Authentication
CVE-2017-7912
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.65% / 69.81%
||
7 Day CHG~0.00%
Published-08 Apr, 2019 | 14:17
Updated-05 Aug, 2024 | 16:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Hanwha Techwin SRN-4000, SRN-4000 firmware versions prior to SRN4000_v2.16_170401, A specially crafted http request and response could allow an attacker to gain access to the device management page with admin privileges without proper authentication.

Action-Not Available
Vendor-hanwhasecurityHanwha Techwin
Product-srn-4000_firmwaresrn-4000SRN-4000
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-287
Improper Authentication
CVE-2017-7919
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-1.25% / 78.50%
||
7 Day CHG~0.00%
Published-03 Jul, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Authentication issue was discovered in Newport XPS-Cx and XPS-Qx. An attacker may bypass authentication by accessing a specific uniform resource locator (URL).

Action-Not Available
Vendor-newportn/a
Product-xps-qxxps-cx_firmwarexps-cxxps-qx_firmwareNewport XPS-Cx, XPS-Qx
CWE ID-CWE-287
Improper Authentication
CVE-2024-5432
Matching Score-4
Assigner-Wordfence
ShareView Details
Matching Score-4
Assigner-Wordfence
CVSS Score-9.8||CRITICAL
EPSS-0.82% / 73.41%
||
7 Day CHG~0.00%
Published-20 Jun, 2024 | 02:08
Updated-01 Aug, 2024 | 21:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Lifeline Donation <= 1.2.6 - Authentication Bypass

The Lifeline Donation plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 1.2.6. This is due to insufficient verification on the user being supplied during the checkout through the plugin. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.

Action-Not Available
Vendor-webinanewebinnanewebinnane
Product-lifeline_donationLifeline Donationlifeline_donation
CWE ID-CWE-287
Improper Authentication
CVE-2017-7909
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-1.60% / 80.96%
||
7 Day CHG~0.00%
Published-06 May, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Use of Client-Side Authentication issue was discovered in Advantech B+B SmartWorx MESR901 firmware versions 1.5.2 and prior. The web interface uses JavaScript to check client authentication and redirect unauthorized users. Attackers may intercept requests and bypass authentication to access restricted web pages.

Action-Not Available
Vendor-advantech_b\+b_smartworxn/a
Product-mesr901_firmwaremesr901Advantech B+B SmartWorx MESR901
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-603
Use of Client-Side Authentication
CVE-2017-7546
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-9.8||CRITICAL
EPSS-33.20% / 96.76%
||
7 Day CHG~0.00%
Published-16 Aug, 2017 | 18:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

PostgreSQL versions before 9.2.22, 9.3.18, 9.4.13, 9.5.8 and 9.6.4 are vulnerable to incorrect authentication flaw allowing remote attackers to gain access to database accounts with an empty password.

Action-Not Available
Vendor-The PostgreSQL Global Development GroupDebian GNU/Linux
Product-debian_linuxpostgresqlpostgresql
CWE ID-CWE-287
Improper Authentication
CVE-2017-7931
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-2.28% / 84.00%
||
7 Day CHG~0.00%
Published-06 Jun, 2018 | 20:00
Updated-17 Sep, 2024 | 02:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.

Action-Not Available
Vendor-ICS-CERTABB
Product-ip_gatewayip_gateway_firmwareABB IP GATEWAY
CWE ID-CWE-287
Improper Authentication
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 25
  • 26
  • Next
Details not found