CVE-2020-7540

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-11 Dec, 2020 | 00:52
Updated At-04 Aug, 2024 | 09:33
Rejected At-
Credits

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:11 Dec, 2020 | 00:52
Updated At:04 Aug, 2024 | 09:33
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Affected Products
Vendor
n/a
Product
Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
Versions
Affected
  • Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
Problem Types
TypeCWE IDDescription
CWECWE-306CWE-306: Missing Authentication for Critical Function
Type: CWE
CWE ID: CWE-306
Description: CWE-306: Missing Authentication for Critical Function
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-343-04/
x_refsource_CONFIRM
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-343-04/
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-343-04/
x_refsource_CONFIRM
x_transferred
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-343-04/
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:11 Dec, 2020 | 01:15
Updated At:10 Apr, 2024 | 12:28

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp341000_firmware>>Versions before 3.30(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp341000>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342000_firmware>>Versions before 3.30(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342000>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp342000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102_firmware>>Versions before 3.30(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102cl_firmware>>Versions before 3.30(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420102cl>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102cl:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342020_firmware>>Versions before 3.30(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp342020>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302_firmware>>Versions before 3.30(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302cl_firmware>>Versions before 3.30(exclusive)
cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m340_bmxp3420302cl>>-
cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302cl:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0100_firmware>>Versions before 3.3(exclusive)
cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0100>>-
cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0110_firmware>>Versions before 6.5(exclusive)
cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoe0110>>-
cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noe77101_firmware>>Versions before 7.1(exclusive)
cpe:2.3:o:schneider-electric:140noe77101_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noe77101>>-
cpe:2.3:h:schneider-electric:140noe77101:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noe77111_firmware>>Versions before 7.1(exclusive)
cpe:2.3:o:schneider-electric:140noe77111_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noe77111>>-
cpe:2.3:h:schneider-electric:140noe77111:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65150_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:140cpu65150_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65150>>-
cpe:2.3:h:schneider-electric:140cpu65150:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:140cpu65160_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140cpu65160>>-
cpe:2.3:h:schneider-electric:140cpu65160:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc78000_firmware>>Versions before 1.74(exclusive)
cpe:2.3:o:schneider-electric:140noc78000_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc78000>>-
cpe:2.3:h:schneider-electric:140noc78000:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc78100_firmware>>Versions before 1.74(exclusive)
cpe:2.3:o:schneider-electric:140noc78100_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc78100>>-
cpe:2.3:h:schneider-electric:140noc78100:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc77101_firmware>>Versions before 1.08(exclusive)
cpe:2.3:o:schneider-electric:140noc77101_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>140noc77101>>-
cpe:2.3:h:schneider-electric:140noc77101:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp574634_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:tsxp574634_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp574634>>-
cpe:2.3:h:schneider-electric:tsxp574634:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp575634_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:tsxp575634_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp575634>>-
cpe:2.3:h:schneider-electric:tsxp575634:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp576634_firmware>>Versions before 6.1(exclusive)
cpe:2.3:o:schneider-electric:tsxp576634_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxp576634>>-
cpe:2.3:h:schneider-electric:tsxp576634:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety4103_firmware>>Versions before 6.2(exclusive)
cpe:2.3:o:schneider-electric:tsxety4103_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety4103>>-
cpe:2.3:h:schneider-electric:tsxety4103:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety5103_firmware>>Versions before 6.4(exclusive)
cpe:2.3:o:schneider-electric:tsxety5103_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tsxety5103>>-
cpe:2.3:h:schneider-electric:tsxety5103:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoc0401_firmware>>Versions before 2.10(exclusive)
cpe:2.3:o:schneider-electric:bmxnoc0401_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnoc0401>>-
cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnor200h_firmware>>*
cpe:2.3:o:schneider-electric:bmxnor200h_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmxnor200h>>-
cpe:2.3:h:schneider-electric:bmxnor200h:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-306Primarycybersecurity@se.com
CWE ID: CWE-306
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.se.com/ww/en/download/document/SEVD-2020-343-04/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-343-04/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

744Records found

CVE-2012-0931
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.15% / 88.68%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-287
Improper Authentication
CVE-2020-25176
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.1||CRITICAL
EPSS-3.51% / 87.64%
||
7 Day CHG~0.00%
Published-18 Mar, 2022 | 18:00
Updated-16 Apr, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal

Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.

Action-Not Available
Vendor-xylemRockwell Automation, Inc.
Product-micro850saitel_dpmultismart_firmwareisagraf_runtimeeasergy_t300epas_gtwmicro820pacis_gtw_firmwaremicro830micro830_firmwaremicro870_firmwaremicro820_firmwaremicro870easergy_c5_firmwaresaitel_drmicro850_firmwarepacis_gtwsaitel_dr_firmwarecp-3saitel_dp_firmwareisagraf_free_runtimeepas_gtw_firmwareeasergy_c5micom_c264mc-31aadvance_controllermicom_c264_firmwarescd2200_firmwareeasergy_t300_firmwaremicro810micro810_firmwareISaGRAF Runtime
CWE ID-CWE-23
Relative Path Traversal
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-37036
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.10% / 28.05%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 16:48
Updated-14 Aug, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.

Action-Not Available
Vendor-
Product-sage_4400sage_1410sage_3030_magnumsage_2400sage_rtu_firmwaresage_1450sage_1430Sage 4400Sage 1450Sage 1410Sage 3030 MagnumSage 1430Sage 2400sage_4400_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10575
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-10||CRITICAL
EPSS-0.40% / 60.83%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 04:35
Updated-19 Nov, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on the network and potentially impacting connected devices.

Action-Not Available
Vendor-
Product-ecostruxure_it_gatewayEcoStruxure IT Gatewayecostruxure_it_gateway
CWE ID-CWE-862
Missing Authorization
CVE-2023-5399
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-25.06% / 96.19%
||
7 Day CHG~0.00%
Published-04 Oct, 2023 | 18:07
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command.

Action-Not Available
Vendor-Schneider Electric SE
Product-spacelogic_c-bus_toolkitC-Bus Toolkit
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-5402
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 51.03%
||
7 Day CHG~0.00%
Published-04 Oct, 2023 | 17:59
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network.

Action-Not Available
Vendor-Schneider Electric SE
Product-c-bus_toolkitC-Bus Toolkit
CWE ID-CWE-269
Improper Privilege Management
CVE-2023-5391
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.35% / 57.55%
||
7 Day CHG~0.00%
Published-04 Oct, 2023 | 18:13
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application.

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_monitoring_expertecostruxure_power_operation_with_advanced_reportsecostruxure_power_scada_operation_with_advanced_reportsEcoStruxure Power SCADA Operation with Advanced ReportsEcoStruxure Power Operation (EPO) with Advanced ReportsEcoStruxure Power Monitoring Expert
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2019-6855
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.19% / 40.95%
||
7 Day CHG~0.00%
Published-06 Jan, 2020 | 22:56
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

Action-Not Available
Vendor-n/a
Product-modicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_m580_bmep583040_firmwaremodicon_m340_bmxp3420302_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh584040smodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m580_bmeh586040modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp342000modicon_m340_bmxp341000modicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep584040smodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmeh584040modicon_m580_bmep585040modicon_m580_bmeh584040_firmwareunity_promodicon_m340_bmxp3420302modicon_m580_bmep584020modicon_m580_bmeh584040s_firmwaremodicon_m580_bmep582040s_firmwaremodicon_m580_bmep582040smodicon_m580_bmeh582040_firmwaremodicon_m340_bmxp342020modicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwaremodicon_m580_bmep581020modicon_m580_bmep582020_firmwaremodicon_m580_bmeh586040_firmwaremodicon_m340_bmxp342000_firmwaremodicon_m340_bmxp3420102modicon_m580_bmep586040_firmware EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6840
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.50% / 66.19%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:19
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed.

Action-Not Available
Vendor-
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0002meg6501-0001_firmwaremeg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Server
CWE ID-CWE-134
Use of Externally-Controlled Format String
CVE-2019-6823
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-12.53% / 93.96%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:41
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-6824
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-11.58% / 93.67%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:44
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2019-6814
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-66.93% / 98.56%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:38
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI.

Action-Not Available
Vendor-n/a
Product-net5504_firmwarenet5500_firmwarenet5501-inet5508net5516_firmwarenet5508_firmwarenet5516net5501_firmwarenet5504net5501-xt_firmwarenet5501-xtnet5500net5501-i_firmwarenet5501ÊNET55XX Encoder with firmware prior to version 2.1.9.Ê
CWE ID-CWE-287
Improper Authentication
CVE-2016-5818
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.38% / 59.39%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_pm8eccpowerlogic_pm8ecc_firmwareSchneider Electric PowerLogic 2.651 and older
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2023-29412
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-6.16% / 90.85%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-28004
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.67% / 82.13%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 21:16
Updated-02 Aug, 2024 | 12:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.

Action-Not Available
Vendor-
Product-powerlogic_hdpm6000_firmwarepowerlogic_hdpm6000PowerLogic HDPM6000
CWE ID-CWE-129
Improper Validation of Array Index
CVE-2023-25549
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-3.67% / 87.91%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:35
Updated-03 Mar, 2025 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-25550
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-3.67% / 87.91%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:36
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2022-0223
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.57% / 68.51%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-26507
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.70% / 91.27%
||
7 Day CHG~0.00%
Published-14 Apr, 2022 | 12:04
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-attn/a
Product-ecostruxure_process_expertecostruxure_control_expertremoteconnectxmillscadapack_470scadapack_570scadapack_574scadapack_575scadapack_474n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2017-7574
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.56%
||
7 Day CHG~0.00%
Published-06 Apr, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_tm221ce16r_firmwaresomachinemodicon_tm221ce16rn/a
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-9956
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.49% / 65.43%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-9957
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 63.38%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-5155
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.3||HIGH
EPSS-0.64% / 70.64%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_historianSchneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2015-0982
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-6.02% / 90.73%
||
7 Day CHG~0.00%
Published-14 Mar, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-pelco_ds-nvn/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32527
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 82.70%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-7790
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.13% / 78.36%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 21:00
Updated-16 Sep, 2024 | 19:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.

Action-Not Available
Vendor-
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions prior to firmware V1.6.2.0
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-30235
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.27% / 50.60%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2018-1126
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.49% / 65.60%
||
7 Day CHG~0.00%
Published-23 May, 2018 | 13:00
Updated-17 Dec, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.

Action-Not Available
Vendor-procps-ng_project[UNKNOWN]Red Hat, Inc.Debian GNU/LinuxCanonical Ltd.
Product-enterprise_linux_serverubuntu_linuxdebian_linuxprocps-ngenterprise_linux_server_ausenterprise_linux_workstationenterprise_linuxenterprise_linux_server_tusenterprise_linux_desktopstruxureware_data_center_expertprocps-ng, procps
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2017-6028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.32% / 54.86%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m241modicon_m251modicon_m251_firmwaremodicon_m241_firmwareSchneider Electric Modicon PLCs
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-7228
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.69% / 71.90%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 23:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-287
Improper Authentication
CVE-2021-22784
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.7||MEDIUM
EPSS-1.43% / 80.65%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit v1.15.8 and prior
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-22823
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-0.32% / 55.08%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-22805
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-0.23% / 46.15%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-32528
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.25% / 48.47%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-22809
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.51% / 66.36%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 00:00
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7479
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.14% / 33.88%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:18
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-4516
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.03% / 7.71%
||
7 Day CHG~0.00%
Published-14 Sep, 2023 | 08:54
Updated-27 Feb, 2025 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content.

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Update Service (IGSSupdateservice.exe)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-6820
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.2||HIGH
EPSS-0.30% / 53.58%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:40
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2

Action-Not Available
Vendor-n/a
Product-pacdrive_ecomodicon_m241_firmwarepacdrive_pro2_firmwaremodicon_m200_firmwarepacdrive_eco_firmwaremodicon_m221_firmwaremodicon_m241modicon_m258atv_imc_drive_controller_firmwaremodicon_m258_firmwareatv_imc_drive_controllermodicon_m251_firmwaremodicon_m200modicon_lmc078modicon_m100_firmwarepacdrive_promodicon_m221pacdrive_pro2pacdrive_pro_firmwaremodicon_lmc078_firmwaremodicon_lmc058modicon_m100modicon_lmc058_firmwaremodicon_m251Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2017-13997
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-1.59% / 81.65%
||
7 Day CHG~0.00%
Published-02 Oct, 2017 | 05:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_intouchwonderware_indusoft_web_studioSchneider Electric InduSoft Web Studio, InTouch Machine Edition
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-29413
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.39% / 59.91%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 20:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-27980
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.44% / 80.78%
||
7 Day CHG~0.00%
Published-21 Mar, 2023 | 00:00
Updated-05 Feb, 2025 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-custom_reportsigss_dashboardigss_data_serverIGSS Dashboard (DashBoard.exe)IGSS Data Server(IGSSdataServer.exe)Custom Reports (RMS16.dll)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-27983
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.19% / 41.28%
||
7 Day CHG~0.00%
Published-21 Mar, 2023 | 00:00
Updated-05 Feb, 2025 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).

Action-Not Available
Vendor-Schneider Electric SE
Product-custom_reportsigss_dashboardigss_data_serverIGSS Dashboard (DashBoard.exe)IGSS Data Server(IGSSdataServer.exe)Custom Reports (RMS16.dll)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-8530
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.9||MEDIUM
EPSS-0.20% / 42.19%
||
7 Day CHG~0.00%
Published-11 Oct, 2024 | 13:55
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS.

Action-Not Available
Vendor-
Product-Data Center Expertdata_center_expert
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2014-9197
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-0.27% / 50.55%
||
7 Day CHG~0.00%
Published-27 Jan, 2015 | 11:00
Updated-05 Sep, 2025 | 22:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Action-Not Available
Vendor-Schneider Electric SE
Product-tsxetg3000tsxetg3021etg3000_factorycast_hmi_gateway_firmwaretsxetg3010tsxetg3022ETG3000 FactoryCast HMI Gateway
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18937
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-30.11% / 96.68%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 18:50
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.

Action-Not Available
Vendor-eq-3scriptparser_projectn/a
Product-homematic_ccu2_firmwarescriptparserhomematic_ccu3_firmwarehomematic_ccu3homematic_ccu2n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18938
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-30.11% / 96.68%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 18:52
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.

Action-Not Available
Vendor-eq-3hm_email_projectn/a
Product-homematic_ccu2_firmwarehm_emailhomematic_ccu3_firmwarehomematic_ccu3homematic_ccu2n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-19104
Matching Score-4
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Matching Score-4
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-9.1||CRITICAL
EPSS-0.24% / 47.40%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 14:31
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Improper Authentication and Access Control

The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.

Action-Not Available
Vendor-Busch-Jaeger (ABB)ABB
Product-6186\/11_firmware6186\/11tg\/s3.2tg\/s3.2_firmware6186/11 Telefon-Gateway TG/S 3.2 Telephone Gateway
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-50593
Matching Score-4
Assigner-VulnCheck
ShareView Details
Matching Score-4
Assigner-VulnCheck
CVSS Score-9.3||CRITICAL
EPSS-0.32% / 54.85%
||
7 Day CHG+0.06%
Published-06 Nov, 2025 | 19:57
Updated-08 Dec, 2025 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Advantech iView < v5.7.04 Build 6425 search_term Parameter SQL Injection RCE

Advantech iView versions prior to v5.7.04 build 6425 contain a vulnerability within the SNMP management tool that allows for remote attackers to bypass authentication checks and reach a SQL injection vulnerability within the ‘search_term’ parameter to the ‘NetworkServlet’ endpoint. Successful exploitation allows for remote code execution with administrator privileges.

Action-Not Available
Vendor-Advantech (Advantech Co., Ltd.)
Product-iviewiView
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-18666
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.52% / 87.66%
||
7 Day CHG~0.00%
Published-15 May, 2020 | 17:18
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dap-1360_revision_f_firmwaredap-1360_revision_fn/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18939
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-30.11% / 96.68%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 18:53
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.

Action-Not Available
Vendor-hm-print_projecteq-3n/a
Product-homematic_ccu2_firmwarehm-printhomematic_ccu3_firmwarehomematic_ccu3homematic_ccu2n/a
CWE ID-CWE-306
Missing Authentication for Critical Function
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 14
  • 15
  • Next
Details not found