In Veritas NetBackup OpsCenter, a hard-coded credential exists that could be used to exploit the underlying VxSS subsystem. This affects 8.x through 8.3.0.2, 9.x through 9.0.0.1, 9.1.x through 9.1.0.1, and 10.
Unsafe storage of AD credentials in Ivanti DSM netinst 5.1 due to a static, hard-coded encryption key.
Encrypted database credentials in LaborOfficeFree affecting version 19.10. This vulnerability allows an attacker to read and extract the username and password from the database of 'LOF_service.exe' and 'LaborOfficeFree.exe' located in the '%programfiles(x86)%\LaborOfficeFree\' directory. This user can log in remotely and has root-like privileges.
Bitnami Cassandra container images are affected by a retained default superuser vulnerability. When a custom administrator account is configured via the CASSANDRA_USER environment variable, the container initialization script creates the new superuser account but fails to drop the built-in cassandra account in certain scenarios. This leaves the default cassandra:cassandra superuser active as an unintended access path. Affected versions — Container image: 4.0.x prior to 4.0.20-photon-5-r7; 4.1.x prior to 4.1.11-photon-5-r7; 5.0.x prior to 5.0.8-photon-5-r4 / 5.0.8-debian-12-r3.
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.
Seiko SkyBridge MB-A100/A110 v4.2.0 and below implements a hard-coded passcode for the root account. Attackers are able to access the passcord via the file /etc/ciel.cfg.
TOTOLINK A3002RU V3.0.0-B20220304.1804 has a hardcoded password for root in /etc/shadow.sample.
A vulnerability has been found in osuuu LightPicture up to 1.2.2. This issue affects some unknown processing of the file /public/install/lp.sql of the component API Upload Endpoint. Such manipulation of the argument key leads to hard-coded credentials. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
FreePBX is an open source IP PBX. From 15.0.42 to before 16.0.45 and 17.0.7, unauthenticated users may be able to access the User Control Panel (UCP) using hard-coded initial template credentials if these were not immediately changed by the Administrator who enabled UCP. Authenticated access to ACP is required for the initial setup of UCP generic templates, but after that, without further steps by the admin, unauthenticated users may be able to gain access. This vulnerability is fixed in 16.0.45 and 17.0.7.
This vulnerability allows remote attackers to bypass authentication on affected installations of Vinchin Backup and Recovery 6.5.0.17561. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the MySQL server. The server uses a hard-coded password for the administrator user. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17139.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain LDAP user privileges.
SOPlanning before 1.47 has Incorrect Access Control because certain secret key information, and the related authentication algorithm, is public. The key for admin is hardcoded in the installation code, and there is no key for publicsp (which is a guest account).
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations.
The management tool in MyLittleAdmin 3.8 allows remote attackers to execute arbitrary code because machineKey is hardcoded (the same for all customers' installations) in web.config, and can be used to send serialized ASP code.
libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.
A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
An issue was discovered in Foxit Reader and PhantomPDF before 9.7.2. It allows information disclosure of a hardcoded username and password in the DocuSign plugin.
The installation of Microsoft Exchange 2000 before Rev. A creates a user account with a known password, which could allow attackers to gain privileges, aka the "Exchange User Account" vulnerability.
In Ruckus Network Director (RND) < 4.5.0.54, the OVA appliance contains hardcoded credentials for the ruckus PostgreSQL database user. In the default configuration, the PostgreSQL service is accessible over the network on TCP port 5432. An attacker can use the hardcoded credentials to authenticate remotely, gaining superuser access to the database. This allows creation of administrative users for the web interface, extraction of password hashes, and execution of arbitrary OS commands.
The upload.cgi binary, responsible for processing device backups, contains a hardcoded AES encryption key. This allows an attacker to decrypt, modify, and re-encrypt system backups, facilitating persistent backdoor injection.
ClipBucket 5.5.2 is affected by an improper access control issue where the product is shipped or deployed with hardcoded default administrative credentials. An unauthenticated remote attacker can log in to the administrative panel using these default credentials, resulting in full administrative control of the application.
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
D-Link DIR-605L Hardware Revision B2 (End-of-Life, EOL) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn76_dlwbr_dir605L" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
An authentication bypass vulnerability exists in the web interface /action/factory* functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP header can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.
D-Link DIR-600L Hardware Revision B1 (End-of-Life) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn61_dlwbr_dir600L" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.
Snap One WattBox 800 and 820 series firmware versions prior to 2.10.0.0 contain undisclosed diagnostic HTTP endpoints that require only the device MAC address and service tag for authentication, both of which are printed in plaintext on the physical device label. Attackers with access to the device label or documentation containing these values can authenticate to the several endpoints and execute arbitrary commands as root on the device.
A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain SuperUser access to the device.
USR IOT 4G LTE Industrial Cellular VPN Router v1.0.36 was discovered to contain hard-coded credentials for its highest privileged account. The credentials cannot be altered through normal operation of the device.
Rakuten Casa version AP_F_V1_4_1 or AP_F_V2_0_0 uses a hard-coded credential which may allow a remote unauthenticated attacker to log in with the root privilege and perform an arbitrary operation.
The optional Web Screens and Global Search features for Sage 300 through version 2022 use a hard-coded 40-byte blowfish key ("LandlordPassKey") to encrypt and decrypt secrets stored in configuration files and in database tables.
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
INPRAX "iZZi connect" application on Android contains hard-coded MQTT queue credentials. The same MQTT queue is used by corresponding physical recuperation devices. Exploiting this vulnerability could potentially allow unauthorized access to manage and read parameters of the recuperation unit "reQnet iZZi".This issue affects "iZZi connect" application versions before 2024010401.
Hardcoded admin token in SoundBar apps in Linkplay SDK 1.00 allows remote attackers to gain admin privilege access in linkplay antifactory
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
Anevia Flamingo XL/XS 3.6.20 contains a critical vulnerability with weak default administrative credentials that can be easily guessed. Attackers can leverage these hard-coded credentials to gain full remote system control without complex authentication mechanisms.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
A CWE-798 “Use of Hard-coded Credentials” vulnerability in the MariaDB database of the web application allows a remote unauthenticated attacker to access the database service and all included data with the same privileges of the web application. This issue affects: AiLux imx6 bundle below version imx6_1.0.7-2.
Taiwan Secom Dr.ID Access Control system’s login page has a hard-coded credential in the source code. An unauthenticated remote attacker can use the hard-coded credential to acquire partial system information and modify system setting to cause partial disrupt of service.
ZyXEL ZyWALL 1050 has a hard-coded password for the Quagga and Zebra processes that is not changed when it is set by a user, which allows remote attackers to gain privileges.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.