A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.
D-LINK DWL-6610 FW_v_4.3.0.8B003C was discovered to contain a command injection vulnerability in the function config_upload_handler. This vulnerability allows attackers to execute arbitrary commands via the configRestore parameter.
BeyondTrust Privileged Remote Access (PRA) and Remote Support (RS) versions 23.2.1 and 23.2.2 contain a command injection vulnerability which can be exploited through a malicious HTTP request. Successful exploitation of this vulnerability can allow an unauthenticated remote attacker to execute underlying operating system commands within the context of the site user. This issue is fixed in version 23.2.3.
TP-Link Tapo C200 IP camera, on its 1.1.15 firmware version and below, is affected by an unauthenticated RCE vulnerability, present in the uhttpd binary running by default as root. The exploitation of this vulnerability allows an attacker to take full control of the camera.
An issue in TOTOLINK X6000R V9.4.0cu.652_B20230116 and V9.4.0cu.852_B20230719 allows a remote attacker to execute arbitrary code via the hostName parameter of the switchOpMode component.
QNAP discovered a number of command injection vulnerabilities found in Music Station versions 4.8.6 (for QTS 4.2.x), 5.0.7 (for QTS 4.3.x), and earlier. If exploited, these vulnerabilities may allow a remote attacker to run arbitrary commands on the NAS.
The restapps (aka Rest Phone apps) module for Sangoma FreePBX and PBXact 13, 14, and 15 through 15.0.19.2 allows remote code execution via a URL variable to an AMI command.
/cgi-bin/activate.cgi on Draytek Vigor3900, Vigor2960, and Vigor300B devices before 1.5.1 allows remote attackers to achieve command injection via a remote HTTP request in DEBUG mode.
An issue in TOTOLINK X6000R V9.4.0cu.652_B20230116 and V9.4.0cu.852_B20230719 allows a remote attacker to execute arbitrary code via the IP parameter of the setDiagnosisCfg component.
D-LINK DIR-806 1200M11AC wireless router DIR806A1_FW100CNb11 is vulnerable to command injection due to lax filtering of HTTP_ST parameters.
TOTOLINK X18 V9.1.0cu.2024_B20220329 was discovered to contain a command injection vulnerability via the hostname parameter in the setOpModeCfg function.
This affects all versions of package gitblame. The injection point is located in line 15 in lib/gitblame.js.
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 werediscovered to contain a command injection vulnerability via the mac parameter in the bs_SetMacBlack function.
Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
systeminformation is a System Information Library for Node.JS. Versions 5.0.0 through 5.21.6 have a SSID Command Injection Vulnerability. The problem was fixed with a parameter check in version 5.21.7. As a workaround, check or sanitize parameter strings that are passed to `wifiConnections()`, `wifiNetworks()` (string only).
An issue in TOTOLINK X6000R V9.4.0cu.652_B20230116 and V9.4.0cu.852_B20230719 allows a remote attacker to execute arbitrary code via the command parameter of the setting/setTracerouteCfg component.
Command Execution vulnerability in China Mobile Communications China Mobile Intelligent Home Gateway v.HG6543C4 allows a remote attacker to execute arbitrary code via the shortcut_telnet.cg component.
A vulnerability was found in D-Link DIR-619L 2.04B04. It has been classified as critical. This affects the function formSysCmd. The manipulation of the argument sysCmd leads to command injection. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.
An issue D-Link DIR-816-A2 DIR-816A2_FWv1.10CNB05_R1B011D88210 allows a remote attacker to execute arbitrary code via system() function in the bin/goahead file
A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.
Retrieval-based-Voice-Conversion-WebUI is a voice changing framework based on VITS. Versions 2.2.231006 and prior are vulnerable to command injection. The variables exp_dir1, among others, take user input and pass it to the click_train function, which concatenates them into a command that is run on the server. This can lead to arbitrary command execution. As of time of publication, no known patches exist.
Retrieval-based-Voice-Conversion-WebUI is a voice changing framework based on VITS. Versions 2.2.231006 and prior are vulnerable to command injection. The variables exp_dir1, np7 and f0method8 take user input and pass it into the extract_f0_feature function, which concatenates them into a command that is run on the server. This can lead to arbitrary command execution. As of time of publication, no known patches exist.
An issue was discovered in Titan SpamTitan 7.07. Improper input sanitization of the parameter community on the page snmp-x.php would allow a remote attacker to inject commands into the file snmpd.conf that would allow executing commands on the target server.
Retrieval-based-Voice-Conversion-WebUI is a voice changing framework based on VITS. Versions 2.2.231006 and prior are vulnerable to command injection. The variables exp_dir1, np7, trainset_dir4 and sr2 take user input and pass it to the preprocess_dataset function, which concatenates them into a command that is run on the server. This can lead to arbitrary command execution. As of time of publication, no known patches exist.
Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow a video replay attack after ARP cache poisoning has been achieved.
A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230722 and classified as critical. This issue affects some unknown processing of the file importhtml.php. The manipulation of the argument sql leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-235967. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
N.V.K.INTER CO., LTD. (NVK) iBSG v3.5 was discovered to contain a command injection vulnerability via the system_hostname parameter at /manage/network-basic.php.
Netgear EX8000 V1.0.0.126 is vulnerable to Command Injection via the Iface parameter in the action_wireless function.
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the cmd parameter in the bs_SetCmd function.
Tenda AX3 V16.03.12.11 was discovered to contain a command injection vulnerability via the lanip parameter at /goform/AdvSetLanip.
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the dns1 and dns2 parameters in the bs_SetDNSInfo function.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D8500 before 1.0.3.58, R6900P before 1.3.2.132, R7000P before 1.3.2.132, R7100LG before 1.0.0.64, WNDR3400v3 before 1.0.1.38, and XR300 before 1.0.3.56.
A privilege escalation vulnerability exists in the /bin/login functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted command line argument can lead to a limited-shell escape and elevated capabilities. An attacker can authenticate with hard-coded credentials and execute unblocked default busybox functionality to trigger this vulnerability.
sapi/cgi/cgi_main.c in PHP before 5.3.12 and 5.4.x before 5.4.2, when configured as a CGI script (aka php-cgi), does not properly handle query strings that lack an = (equals sign) character, which allows remote attackers to execute arbitrary code by placing command-line options in the query string, related to lack of skipping a certain php_getopt for the 'd' case.
In vowifi service, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed.
An issue was discovered in D-Link DIR816_A1_FW101CNB04 750m11ac wireless router, The HTTP request parameter is used in the handler function of /goform/form2userconfig.cgi route, which can construct the user name string to delete the user function. This can lead to command injection through shell metacharacters.
A vulnerability was found in Exciting Printer and classified as critical. This issue affects some unknown processing of the file lib/printer/jobs/prepare_page.rb of the component Argument Handler. The manipulation of the argument URL leads to command injection. The patch is named 5f8c715d6e2cc000f621a6833f0a86a673462136. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-217139.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114.
PbootCMS below v3.2.0 was discovered to contain a command injection vulnerability via create_function.
A Command Injection vulnerability has been identified in the MiVoice Office 400 SMB Controller through 1.2.5.23 which could allow a malicious actor to execute arbitrary commands within the context of the system.
matrix-appservice-irc is a Node.js IRC bridge for Matrix. Prior to version 1.0.1, it is possible to craft a command with newlines which would not be properly parsed. This would mean you could pass a string of commands as a channel name, which would then be run by the IRC bridge bot. Versions 1.0.1 and above are patched. There are no robust workarounds to the bug. One may disable dynamic channels in the config to disable the most common execution method but others may exist.
Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function.
A command injection vulnerability in the component /api/cron/settings/setJob/ of OPNsense Community Edition before 23.7 and Business Edition before 23.4.2 allows attackers to execute arbitrary system commands.
COMFAST CF-XR11 V2.7.2 has a command injection vulnerability detected at function sub_4143F0. Attackers can send POST request messages to /usr/bin/webmgnt and inject commands into parameter timestr.
An issue was discovered in D-Link DIR-816 DIR-816A2_FWv1.10CNB05_R1B011D88210 The HTTP request parameter is used in the handler function of /goform/form2userconfig.cgi route, which can construct the user name string to delete the user function. This can lead to command injection through shell metacharacters.
COMFAST CF-XR11 V2.7.2 has a command injection vulnerability detected at function sub_415588. Attackers can send POST request messages to /usr/bin/webmgnt and inject commands into parameter interface and display_name.
Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain a command injection vulnerability via the bs_SetSSIDHide function.
A command injection vulnerability in the component diag_backup.php of OPNsense Community Edition before 23.7 and Business Edition before 23.4.2 allows attackers to execute arbitrary commands via a crafted backup configuration file.
django-sspanel v2022.2.2 was discovered to contain a remote command execution (RCE) vulnerability via the component sspanel/admin_view.py -> GoodsCreateView._post.