In ONAP DCAE through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_htmls.cgi on VStarcam 100T (C7824WIP) KR75.8.53.20 and 200V (C38S) KR203.18.1.20 devices. The web service, network, and account files can be manipulated through a web UI firmware update without any authentication. The attacker can achieve access to the device through a manipulated web UI firmware update.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP VNFSDK through Dublin. By accessing port 8000 of demo-vnfsdk-vnfsdk, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in Squid through 4.7. When handling requests from users, Squid checks its rules to see if the request should be denied. Squid by default comes with rules to block access to the Cache Manager, which serves detailed server information meant for the maintainer. This rule is implemented via url_regex. The handler for url_regex rules URL decodes an incoming request. This allows an attacker to encode their URL to bypass the url_regex check, and gain access to the blocked resource.
Anviz access control devices allow remote attackers to issue commands without a password.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.
A vulnerability was found in harry0703 MoneyPrinterTurbo up to 1.2.6 and classified as critical. Affected by this issue is the function verify_token of the file app/controllers/base.py of the component API Endpoint. The manipulation leads to missing authentication. The attack may be launched remotely.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
A vulnerability was found in SimStudioAI sim up to 37786d371e17d35e0764e1b5cd519d873d90d97b. It has been declared as critical. Affected by this vulnerability is the function POST of the file apps/sim/app/api/files/upload/route.ts of the component Session Handler. The manipulation of the argument Request leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
A vulnerability has been found in TOTOLINK T6 4.1.5cu.748_B20211015 and classified as critical. Affected by this vulnerability is the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument telnet_enabled with the input 1 leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Contec Smart Home 4.15 devices do not require authentication for new_user.php, edit_user.php, delete_user.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
The resolution SAML SSO apps for Atlassian products allow a remote attacker to login to a user account when only the username is known (i.e., no other authentication is provided). The fixed versions are for Jira: 3.6.6.1, 4.0.12, 5.0.5; for Confluence 3.6.6, 4.0.12, 5.0.5; for Bitbucket 2.5.9, 3.6.6, 4.0.12, 5.0.5; for Bamboo 2.5.9, 3.6.6, 4.0.12, 5.0.5; and for Fisheye 2.5.9.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
IBM Security Identity Governance and Intelligence 5.2.6 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. IBM X-Force ID: 192209.
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
A vulnerability classified as critical has been found in code-projects Laundry System 1.0. This affects an unknown part of the file /data/. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Multiple camera devices by UDP Technology, Geutebrück and other vendors allow unauthenticated remote access to sensitive files due to default user authentication settings. This can lead to manipulation of the device and denial of service.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
An issue was discovered in ONAP HOLMES before Dublin. By accessing port 9202 of dep-holmes-engine-mgmt pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP OOM through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
Standalone clients connecting to SAP NetWeaver AS Java via P4 Protocol, versions (SAP-JEECOR 7.00, 7.01; SERVERCOR 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50; CORE-TOOLS 7.00, 7.01, 7.02, 7.05, 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50) do not perform any authentication checks for operations that require user identity leading to Authentication Bypass.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7000 of demo-sdc-sdc-wfd-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An Incorrect Access Control vulnerability was found in Wikimedia MediaWiki 1.27.0 through 1.32.1. Directly POSTing to Special:ChangeEmail would allow for bypassing re-authentication, allowing for potential account takeover.
OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000.
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
PacsOne Server (PACS Server In One Box) below 7.1.1 is affected by incorrect access control, which can result in remotely gaining administrator privileges.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
A vulnerability, which was classified as critical, was found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. Affected is the function genCode of the file novel-admin/src/main/java/com/java2nb/common/controller/GeneratorController.java. The manipulation leads to missing authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7001 of demo-sdc-sdc-wfd-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
A vulnerability in the Open Systems Gateway initiative (OSGi) interface of Cisco Policy Suite before 18.1.0 could allow an unauthenticated, remote attacker to directly connect to the OSGi interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by directly connecting to the OSGi interface. An exploit could allow the attacker to access or change any files that are accessible by the OSGi process. Cisco Bug IDs: CSCvh18017.
A vulnerability in the Policy Builder database of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to connect directly to the Policy Builder database. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by connecting directly to the Policy Builder database. A successful exploit could allow the attacker to access and change any data in the Policy Builder database. Cisco Bug IDs: CSCvh06134.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4001 of demo-sdc-sdc-onboarding-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions.