A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Telerik.Web.UI.dll in Progress Telerik UI for ASP.NET AJAX before R2 2017 SP1 and Sitefinity before 10.0.6412.0 does not properly protect Telerik.Web.UI.DialogParametersEncryptionKey or the MachineKey, which makes it easier for remote attackers to defeat cryptographic protection mechanisms, leading to a MachineKey leak, arbitrary file uploads or downloads, XSS, or ASP.NET ViewState compromise.
Marval MSM v14.19.0.12476 has a 0-Click Account Takeover vulnerability which allows an attacker to change any user's password in the organization, this means that the user can also escalate achieve Privilege Escalation by changing the administrator password.
Insufficiently protected credentials for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable information disclosure and escalation of privilege via network access.
An issue was discovered on D-Link DWR-116 through 1.06, DIR-140L through 1.02, DIR-640L through 1.02, DWR-512 through 2.02, DWR-712 through 2.02, DWR-912 through 2.02, DWR-921 through 2.02, and DWR-111 through 1.01 devices. The administrative password is stored in plaintext in the /tmp/csman/0 file. An attacker having a directory traversal (or LFI) can easily get full router access.
The Olive Tree Ftp Server application 1.32 for Android has Insecure Data Storage because a username and password are stored in the /data/data/com.theolivetree.ftpserver/shared_prefs/com.theolivetree.ftpserver_preferences.xml file as the prefUsername and prefUserpass strings.
NEC Univerge Sv9100 WebPro 6.00.00 devices have Cleartext Password Storage in the Web UI.
An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server (via /Electron/download directory traversal in conjunction with a path component that uses backslash characters), leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. NOTE: this issue exists because of an incomplete fix for CVE-2022-48482.
KMS Controls BAC-A1616BC BACnet devices have a cleartext password of snowman in the BACKDOOR_NAME variable in the BC_Logon.swf file.
SAP Business Objects Business Intelligence Platform (CMC), version 4.1, 4.2, shows cleartext password in the response, leading to Information Disclosure. It involves social engineering in order to gain access to system and If password is known, it would give administrative rights to the attacker to read/modify delete the data and rights within the system.
STMicroelectronics SPC58 is vulnerable to Missing Protection Mechanism for Alternate Hardware Interface. Code running as Supervisor on the SPC58 PowerPC microcontrollers may disable the System Memory Protection Unit and gain unabridged read/write access to protected assets.
Smart Parking Management System from Honding Technology has an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to access a specific page and obtain plaintext administrator credentials.
Certain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
An attacker with weak credentials could access the TCP port via an open FTP port, allowing an attacker to read sensitive files and write to remotely executable directories.
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials. The affected models are out of support; replacing the device is recommended.
An issue discovered in Relyum RELY-PCIe 22.2.1 and RELY-REC 23.1.0 allows for unauthorized password changes due to no check for current password.
RevelaCode is an AI-powered faith-tech project that decodes biblical verses, prophecies and global events into accessible language. In versions below 1.0.1, a valid MongoDB Atlas URI with embedded username and password was accidentally committed to the public repository. This could allow unauthorized access to production or staging databases, potentially leading to data exfiltration, modification, or deletion. This is fixed in version 1.0.1. Workarounds include: immediately rotating credentials for the exposed database user, using a secret manager (like Vault, Doppler, AWS Secrets Manager, etc.) instead of storing secrets directly in code, or auditing recent access logs for suspicious activity.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can use "show system infor" to discover cleartext TELNET credentials.
Firmware version 4.60 of Zyxel USG devices contains an undocumented account (zyfwp) with an unchangeable password. The password for this account can be found in cleartext in the firmware. This account can be used by someone to login to the ssh server or web interface with admin privileges.
GenX_FX is an advance IA trading platform that will focus on forex trading. A vulnerability was identified in the GenX FX backend where API keys and authentication tokens may be exposed if environment variables are misconfigured. Unauthorized users could gain access to cloud resources (Google Cloud, Firebase, GitHub, etc.).
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
The WebTools component on Canon Oce ColorWave 3500 5.1.1.0 devices allows attackers to retrieve stored SMB credentials via the export feature, even though these are intentionally inaccessible in the UI.
AVE DOMINAplus <=1.10.x suffers from clear-text credentials disclosure vulnerability that allows an unauthenticated attacker to issue a request to an unprotected directory that hosts an XML file '/xml/authClients.xml' and obtain administrative login information that allows for a successful authentication bypass attack.
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the q6xV4aW8bQ4cfD-b password for the axiros account.
It is possible to unmask credentials and other sensitive information on “unprotected” project files, which may allow an attacker to remotely access the C-More Touch Panels EA9 series: firmware versions prior to 6.53 and manipulate system configurations.
D-Link DIR-100 4.03B07 has PPTP and poe information disclosure
An issue was discovered in Nitrokey FIDO U2F firmware through 1.1. Communication between the microcontroller and the secure element transmits credentials in plain. This allows an adversary to eavesdrop the communication and derive the secrets stored in the microcontroller. As a result, the attacker is able to arbitrarily manipulate the firmware of the microcontroller.
An issue in PDQ Smart Deploy V.3.0.2040 allows an attacker to escalate privileges via the Credential encryption routines in SDCommon.dll
Grand MA 300 allows a brute-force attack on the PIN.
ECOA BAS controller’s special page displays user account and passwords in plain text, thus unauthenticated attackers can access the page and obtain privilege with full functionality.
EisBaer Scada - CWE-256: Plaintext Storage of a Password
An isssue in GatesAIr Flexiva FM Transmitter/Exiter Fax 150W allows a remote attacker to gain privileges via the LDAP and SMTP credentials.
Tomcat application credentials are hardcoded in SonicWall GMS and Analytics configuration file. This issue affects GMS: 9.3.2-SP1 and earlier versions; Analytics: 2.5.0.4-R7 and earlier versions.
PostgresNIO is a Swift client for PostgreSQL. Any user of PostgresNIO prior to version 1.14.2 connecting to servers with TLS enabled is vulnerable to a man-in-the-middle attacker injecting false responses to the client's first few queries, despite the use of TLS certificate verification and encryption. The vulnerability is addressed in PostgresNIO versions starting from 1.14.2. There are no known workarounds for unpatched users.
An attacker may obtain the user credentials from the communication between the PLC and the software. As a result, the PLC user program may be uploaded, altered, and/or downloaded.
The local Vuforia web application does not support HTTPS, and federated credentials are passed via basic authentication.
The Orca HCM digital learning platform uses a weak factory default administrator password, which is hard-coded in the source code of the webpage in plain text, thus remote attackers can obtain administrator’s privilege without logging in.
TSplus Remote Work 16.0.0.0 places a cleartext password on the "var pass" line of the HTML source code for the secure single sign-on web portal. NOTE: CVE-2023-31069 is only about the TSplus Remote Access product, not the TSplus Remote Work product.
NVIDIA DGX H100 BMC contains a vulnerability in IPMI, where an attacker may cause insufficient protection of credentials. A successful exploit of this vulnerability may lead to code execution, denial of service, information disclosure, and escalation of privileges.
In processMessageImpl of ClientModeImpl.java, there is a possible credential disclosure in the TOFU flow due to a logic error in the code. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
profile.php in ExtCalendar 2 and earlier allows remote attackers to change the passwords of arbitrary users without providing the original password, and possibly perform other unauthorized actions, via modified values to register.php.
This vulnerability exists in GajShield Data Security Firewall firmware versions prior to v4.28 (except v4.21) due to insecure default credentials which allows remote attacker to login as superuser by using default username/password via web-based management interface and/or exposed SSH port thereby enabling remote attackers to execute arbitrary commands with administrative/superuser privileges on the targeted systems. The vulnerability has been addressed by forcing the user to change their default password to a new non-default password.
Incorrect access control in the web interface in Ruckus Wireless Unleashed through 200.7.10.102.64 allows remote credential fetch via an unauthenticated HTTP request involving a symlink with /tmp and web/user/wps_tool_cache.
Blaauw Remote Kiln Control through v3.00r4 allows an unauthenticated attacker to access MySQL credentials in cleartext in /engine/db.inc, /lang/nl.bak, or /lang/en.bak.
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).
SAP BusinessObjects Platform - versions 420, 430, Information design tool transmits sensitive information as cleartext in the binaries over the network. This could allow an unauthenticated attacker with deep knowledge to gain sensitive information such as user credentials and domain names, which may have a low impact on confidentiality and no impact on the integrity and availability of the system.