CVE-2024-45823 IMPACT An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication.
Rockwell Automation ThinManager ThinServer versions 11.0.0 - 13.0.0 is vulnerable to a heap-based buffer overflow. An attacker could send a specifically crafted TFTP or HTTPS request, causing a heap-based buffer overflow that crashes the ThinServer process. If successfully exploited, this could expose the server to arbitrary remote code execution.
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
A vulnerability in the 802.1x multiple-authentication (multi-auth) feature of Cisco IOS Software could allow an unauthenticated, adjacent attacker to bypass the authentication phase on an 802.1x multi-auth port. The vulnerability is due to a logic change error introduced into the code. An attacker could exploit this vulnerability by trying to access an 802.1x multi-auth port after a successful supplicant has authenticated. An exploit could allow the attacker to bypass the 802.1x access controls and obtain access to the network. Cisco Bug IDs: CSCvg69701.
The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.
CVE-2024-6078 IMPACT An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify data stored in the cloud.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected. Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification.
The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.
Unauthorized access and impersonation can occur in versions 4.6.2.3226 and below of Progress Software's Hybrid Data Pipeline Server on Linux. This vulnerability allows attackers to combine credentials from different sources, potentially leading to client impersonation and unauthorized access. When OAuth Clients perform an OAuth handshake with the Hybrid Data Pipeline Server, the server accepts client credentials from both HTTP headers and request parameters.
An image signature validation bypass vulnerability in Kyverno 1.8.3 and 1.8.4 allows a malicious image registry (or a man-in-the-middle attacker) to inject unsigned arbitrary container images into a protected Kubernetes cluster. This is fixed in 1.8.5. This has been fixed in 1.8.5 and mitigations are available for impacted releases.
A vulnerability was found in WCMS up to 8.3.11. It has been declared as critical. Affected by this vulnerability is the function getMemberByUid of the file /index.php?articleadmin/getallcon of the component Login. The manipulation of the argument uid leads to improper authentication. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
The miniOrange Social Login and Register (Discord, Google, Twitter, LinkedIn) Pro Addon plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 200.3.9. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the username and the user does not have an already-existing account for the service returning the token.
The JobSearch WP Job Board plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 2.9.2. This is due to improper configurations in the 'jobsearch_xing_response_data_callback', 'set_access_tokes', and 'google_callback' functions. This makes it possible for unauthenticated attackers to log in as the first connected Xing user, or any connected Xing user if the Xing id is known. It is also possible for unauthenticated attackers to log in as the first connected Google user if the user has logged in, without subsequently logging out, in thirty days. The vulnerability was partially patched in version 2.8.4.
The Registration Forms – User Registration Forms, Invitation-Based Registrations, Front-end User Profile, Login Form & Content Restriction Social Sites Login plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 1.7.9. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email and the user does not have an already-existing account for the service returning the token.
The WooCommerce - Social Login plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 2.7.7. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email and the user does not have an already-existing account for the service returning the token.
The OAuth Single Sign On – SSO (OAuth Client) plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 6.26.3. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the username and the user does not have an already-existing account for the service returning the token.
The Loginizer Security and Loginizer plugins for WordPress are vulnerable to authentication bypass in all versions up to, and including, 1.9.2. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email and the user does not have an already-existing account for the service returning the token.
A vulnerability was found in Uniway Router 2.0. It has been declared as critical. This vulnerability affects unknown code of the component Administrative Web Interface. The manipulation leads to reliance on ip address for authentication. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. VDB-249766 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07.
ETINET BACKBOX E4.09 and H4.09 mismanages password access control. When a user uses the User ID of the process running BBSV to login to the Backbox UI application, the system procedure (USER_AUTHENTICATE_) used for verifying the Password returns 0 (no error). The reason is that the user is not running the XYGate application. Hence, BBSV assumes the Password is correct. For H4.09, the affected version isT0954V04^AAO. For E4.09, the affected version is 22SEP2020. Note: If your current version is E4.10-16MAY2021 (version procedure T9999V04_16MAY2022_BPAKETI_10), a hotfix (FIXPAK-19OCT-2022) is available in version E4.10-19OCT2022. Resolution to CVE-2021-33895 in version E4.11-19OCT2022
etcd versions 3.2.x before 3.2.26 and 3.3.x before 3.3.11 are vulnerable to an improper authentication issue when role-based access control (RBAC) is used and client-cert-auth is enabled. If an etcd client server TLS certificate contains a Common Name (CN) which matches a valid RBAC username, a remote attacker may authenticate as that user with any valid (trusted) client certificate in a REST API request to the gRPC-gateway.
A remote authentication restriction bypass vulnerability was discovered in Aruba AirWave Management Platform version(s) prior to 8.2.12.1. Aruba has released patches for AirWave Management Platform that address this security vulnerability.
A potential vulnerability in Splunk Enterprise's implementation of DUO MFA allows for bypassing the MFA verification in Splunk Enterprise versions before 8.1.6. The potential vulnerability impacts Splunk Enterprise instances configured to use DUO MFA and does not impact or affect a DUO product or service.
A vulnerability in the HPE Performance Cluster Manager (HPCM) GUI could allow an attacker to bypass authentication.
The Registration Forms – User profile, Content Restriction, Spam Protection, Payment Gateways, Invitation Codes WordPress plugin before 3.1.7.6 has a flaw in the social login implementation, allowing unauthenticated attacker to login as any user on the site by only knowing their user ID or username
Multiple vulnerabilities in the web-based management interface of Cisco Small Business 220 Series Smart Switches could allow an attacker to do the following: Hijack a user session Execute arbitrary commands as a root user on the underlying operating system Conduct a cross-site scripting (XSS) attack Conduct an HTML injection attack For more information about these vulnerabilities, see the Details section of this advisory.
The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the production line.
The ProfilePress Pro plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 4.11.1. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email and the user does not have an already-existing account for the service returning the token.
`@next-auth/upstash-redis-adapter` is the Upstash Redis adapter for NextAuth.js, which provides authentication for Next.js. Applications that use `next-auth` Email Provider and `@next-auth/upstash-redis-adapter` before v3.0.2 are affected by this vulnerability. The Upstash Redis adapter implementation did not check for both the identifier (email) and the token, but only checking for the identifier when verifying the token in the email callback flow. An attacker who knows about the victim's email could easily sign in as the victim, given the attacker also knows about the verification token's expired duration. The vulnerability is patched in v3.0.2. A workaround is available. Using Advanced Initialization, developers can check the requests and compare the query's token and identifier before proceeding.
The Social Share, Social Login and Social Comments Plugin – Super Socializer plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 7.13.68. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, if they have access to the email and the user does not have an already-existing account for the service returning the token. An attacker cannot authenticate as an administrator by default, but these accounts are also at risk if authentication for administrators has explicitly been allowed via the social login. The vulnerability was partially patched in version 7.13.68.
An authentication bypass by assumed-immutable data vulnerability [CWE-302] in the FortiOS SSH login component 7.2.0, 7.0.0 through 7.0.7, 6.4.0 through 6.4.9, 6.2 all versions, 6.0 all versions and FortiProxy SSH login component 7.0.0 through 7.0.5, 2.0.0 through 2.0.10, 1.2.0 all versions may allow a remote and unauthenticated attacker to login into the device via sending specially crafted Access-Challenge response from the Radius server.
An improper authentication vulnerability exists in Pulse Connect Secure <9.1RB that allows an attacker with a users primary credentials to bypass the Google TOTP.
An authentication bypass vulnerability exists in the get_IFTTTTtoken.cgi functionality of Asus RT-AX82U 3.0.0.4.386_49674-ge182230. A specially-crafted HTTP request can lead to full administrative access to the device. An attacker would need to send a series of HTTP requests to exploit this vulnerability.
The Heateor Social Login WordPress plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 1.1.35. This is due to insufficient verification on the user being returned by the social login token. This makes it possible for unauthenticated attackers to log in as any existing user on the site, if they have access to the email and the user does not have an already-existing account for the service returning the token. An attacker cannot authenticate as an administrator by default, but these accounts are also at risk if authentication for administrators has explicitly been allowed via the social login.
ScreenConnect versions 25.2.3 and earlier versions may be susceptible to a ViewState code injection attack. ASP.NET Web Forms use ViewState to preserve page and control state, with data encoded using Base64 protected by machine keys. It is important to note that to obtain these machine keys, privileged system level access must be obtained. If these machine keys are compromised, attackers could create and send a malicious ViewState to the website, potentially leading to remote code execution on the server. The risk does not originate from a vulnerability introduced by ScreenConnect, but from platform level behavior. This had no direct impact to ScreenConnect Client. ScreenConnect 2025.4 patch disables ViewState and removes any dependency on it.
An authentication bypass vulnerability in PandoraNext-TokensTool v0.6.8 and before. An attacker can exploit this vulnerability to access API without any token.
A vulnerability was found in Emlog Pro 2.3.4. It has been classified as problematic. This affects an unknown part of the component Cookie Handler. The manipulation of the argument AuthCookie leads to improper authentication. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-264741 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Jenkins OpenId Connect Authentication Plugin 4.354.v321ce67a_1de8 and earlier does not check the `iss` (Issuer) claim of an ID Token, allowing attackers to subvert the authentication flow, potentially gaining administrator access to Jenkins.
DVR firmware in TAT-76 and TAT-77 series of products, provided by TONNET, contain misconfigured authentication mechanism. Attackers can crack the default password and gain access to the system.
Lif Authentication Server is a server used by Lif to do various tasks regarding Lif accounts. This vulnerability has to do with the account recovery system where there does not appear to be a check to make sure the user has been sent the recovery email and entered the correct code. If the attacker knew the email of the target, they could supply the email and immediately prompt the server to update the password without ever needing the code. This issue has been patched in version 1.7.3.
Jenkins OpenId Connect Authentication Plugin 4.354.v321ce67a_1de8 and earlier does not check the `aud` (Audience) claim of an ID Token, allowing attackers to subvert the authentication flow, potentially gaining administrator access to Jenkins.
An authentication bypass vulnerability exists in the OAS Engine functionality of Open Automation Software OAS Platform v18.00.0072. A specially-crafted series of network requests can lead to arbitrary authentication. An attacker can send a sequence of requests to trigger this vulnerability.
An attacker that has gained access to certain private information can use this to act as other user. Vendor: The Apache Software Foundation Versions Affected: Apache OpenMeetings from 3.1.3 before 7.1.0