A “use after free” code execution vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to craft a DOE file and force the software to use a resource that was already used. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.
A privilege escalation vulnerability exists in the Rockwell Automation ThinManager. When the software starts up, files are deleted in the temporary folder causing the Access Control Entry of the directory to inherit permissions from the parent directory. If exploited, a threat actor could inherit elevated privileges.
In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.
Rockwell Automation DriveTools SP v5.13 and below and Drives AOP v4.12 and below both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system.
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE.
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.
A vulnerability in the 802.1x multiple-authentication (multi-auth) feature of Cisco IOS Software could allow an unauthenticated, adjacent attacker to bypass the authentication phase on an 802.1x multi-auth port. The vulnerability is due to a logic change error introduced into the code. An attacker could exploit this vulnerability by trying to access an 802.1x multi-auth port after a successful supplicant has authenticated. An exploit could allow the attacker to bypass the 802.1x access controls and obtain access to the network. Cisco Bug IDs: CSCvg69701.
The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.
CVE-2024-6078 IMPACT An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify data stored in the cloud.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected. Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification.
CVE-2024-45823 IMPACT An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication.
The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.
An elevation of privilege vulnerability exists when Windows improperly handles authentication requests, aka "Microsoft Windows Elevation of Privilege Vulnerability." This affects Windows 7, Windows Server 2012 R2, Windows RT 8.1, Windows Server 2008, Windows Server 2019, Windows Server 2012, Windows 8.1, Windows Server 2016, Windows Server 2008 R2, Windows 10, Windows 10 Servers.
Shaman 1.0.9: Users can add the line askforpwd=false to his shaman.conf file, without entering the root password in shaman. The next time shaman is run, root privileges are granted despite the fact that the user never entered the root password.
A vulnerability was identified in code-projects Hostel Management System 1.0. This affects an unknown part of the file hostel_manage.exe of the component Login. The manipulation leads to improper authentication. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used.
Authentication Bypass vulnerability in McAfee Data Loss Prevention Endpoint (DLPe) 10.0.x earlier than 10.0.510, and 11.0.x earlier than 11.0.600 allows attackers to bypass local security protection via specific conditions.
NVIDIA DGX-1 SBIOS contains a vulnerability in the Uncore PEI module, where authentication of the code executed by SSA is missing, which may lead to arbitrary code execution, denial of service, escalation of privileges assisted by a firmware implant, information disclosure assisted by a firmware implant, data tampering, and SecureBoot bypass.
Initial xbl_sec revision does not have all the debug policy features and critical checks.
softbus_client_stub in communication subsystem within OpenHarmony-v3.0.5 and prior versions has an authentication bypass vulnerability which allows an "SA relay attack".Local attackers can bypass authentication and attack other SAs with high privilege.
platform_callback_stub in misc subsystem within OpenHarmony-v3.0.5 and prior versions has an authentication bypass vulnerability which allows an "SA relay attack".Local attackers can bypass authentication and attack other SAs with high privilege.
VeryFitPro (com.veryfit2hr.second) 3.2.8 hashes the account's password locally on the device and uses the hash to authenticate in all communication with the backend API, including login, registration and changing of passwords. This allows an attacker in possession of a hash to takeover a user's account, rendering the benefits of storing hashed passwords in the database useless.
A vulnerability in specific versions of Zyxel NBG6818, NBG7815, WSQ20, WSQ50, WSQ60, and WSR30 firmware with pre-configured password management could allow an attacker to obtain root access of the device, if the local attacker dismantles the device and uses a USB-to-UART cable to connect the device, or if the remote assistance feature had been enabled by an authenticated user.
Improper verification of timeout-based authentication in identity credential can lead to invalid authorization in HLOS in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Industrial IOT, Snapdragon Mobile
SAP Business One, version - 10.0, allows a local attacker with access to the victim's browser under certain circumstances, to login as the victim without knowing his/her password. The attacker could so obtain highly sensitive information which the attacker could use to take substantial control of the vulnerable application.
Acronis True Image prior to 2021 Update 4 for Windows and Acronis True Image prior to 2021 Update 5 for macOS allowed an unauthenticated attacker (who has a local code execution ability) to tamper with the micro-service API.
Insufficient protection against brute-force and runtime manipulation in the local authentication component in Two App Studio Journey 5.5.6 on iOS allows local attackers to bypass biometric and PIN-based access control via repeated PIN attempts or dynamic code injection.
Improper validation of program headers containing ELF metadata can lead to image verification bypass in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Consumer Electronics Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wired Infrastructure and Networking
An issue was discovered in Vonage Box Telephone Adapter VDV23 version VDV21-3.2.11-0.5.1, allows local attackers to bypass UART authentication controls and read/write arbitrary values to the memory of the device.
Inappropriate implementation in the ChromeOS Readiness Tool installer on Windows prior to 1.0.2.0 loosens DCOM access rights on two objects allowing an attacker to potentially bypass discretionary access controls.
IBM Spectrum Protect for Enterprise Resource Planning 7.1 and 8.1, if tracing is activated, the IBM Spectrum Protect node password may be displayed in plain text in the ERP trace file. IBM X-Force ID: 154280.
An image with a version lower than the fuse version may potentially be booted lead to improper authentication.
A flaw was found in the way pacemaker's client-server authentication was implemented in versions up to and including 2.0.0. A local attacker could use this flaw, and combine it with other IPC weaknesses, to achieve local privilege escalation.
In Arista's MOS (Metamako Operating System) software which is supported on the 7130 product line, under certain conditions, a user may be able to execute commands despite not having the privileges to do so. This issue affects: Arista Metamako Operating System All releases in the MOS-0.1x train MOS-0.32.0 and prior releases
An Authentication Bypass vulnerability exists in the MatchPasswordData function in DBEngine.dll in Filemaker Pro 13.03 and Filemaker Pro Advanced 12.04, which could let a malicious user obtain elevated privileges.
A vulnerability in the authentication mechanism of Brocade Fabric OS versions before Brocade Fabric OS v.9.0.1a, v8.2.3a and v7.4.2h could allow a user to Login with empty password, and invalid password through telnet, ssh and REST.
A locally authenticated attacker with low privileges can bypass authentication due to insecure inter-process communication.
Intent redirection in Samsung Experience Service versions 10.8.0.4 in Android P(9.0) below, and 12.2.0.5 in Android Q(10.0) above allows attacker to execute privileged action.
Froxlor is open-source server administration software. A vulnerability in versions prior to 2.2.6 allows users (such as resellers or customers) to create accounts with the same email address as an existing account. This creates potential issues with account identification and security. This vulnerability can be exploited by authenticated users (e.g., reseller, customer) who can create accounts with the same email address that has already been used by another account, such as the admin. The attack vector is email-based, as the system does not prevent multiple accounts from registering the same email address, leading to possible conflicts and security issues. Version 2.2.6 fixes the issue.
suPHP before 0.7.2 source-highlighting feature allows security bypass which could lead to arbitrary code execution
Improper cleaning of secure memory between authenticated users can lead to face authentication bypass in Snapdragon Auto, Snapdragon Compute, Snapdragon Connectivity, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Wired Infrastructure and Networking
In lockAllProfileTasks of RootWindowContainer.java, there is a possible way to access the work profile without the profile PIN, after logging in. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-9 Android-10 Android-11 Android-8.1Android ID: A-177457096