An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow in the heap. potentially resulting in a complete loss of confidentiality, integrity, and availability.
Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.
A privilege escalation vulnerability exists in the Rockwell Automation affected products. The vulnerability occurs due to improper default file permissions allowing users to exfiltrate credentials and escalate privileges.
CVE-2024-7513 IMPACT A code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions.
A privilege escalation vulnerability exists in the affected products which could allow a malicious user with basic privileges to access functions which should only be available to users with administrative level privileges. If exploited, an attacker could read sensitive data, and create users. For example, a malicious user with basic privileges could perform critical functions such as creating a user with elevated privileges and reading sensitive information in the “views” section.
Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data.
CVE-2024-45826 IMPACT Due to improper input validation, a path traversal and remote code execution vulnerability exists when the ThinManager® processes a crafted POST request. If exploited, a user can install an executable file.
A server-side request forgery security issue exists within Rockwell Automation ThinManager® software due to the lack of input sanitization. Authenticated attackers can exploit this vulnerability by specifying external SMB paths, exposing the ThinServer® service account NTLM hash.
A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.
A privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable.
A privilege escalation vulnerability exists in the affected product. The vulnerability allows low-privilege users to edit scripts, bypassing Access Control Lists, and potentially gaining further access within the system.
Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an input validation vulnerability. The FactoryTalk VantagePoint SQL Server lacks input validation when users enter SQL statements to retrieve information from the back-end database. If successfully exploited, this could allow a user with basic user privileges to perform remote code execution on the server.
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected. Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.
CVE-2024-6078 IMPACT An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify data stored in the cloud.
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.
CVE-2024-45823 IMPACT An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.
A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.
An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
A vulnerability in the 802.1x multiple-authentication (multi-auth) feature of Cisco IOS Software could allow an unauthenticated, adjacent attacker to bypass the authentication phase on an 802.1x multi-auth port. The vulnerability is due to a logic change error introduced into the code. An attacker could exploit this vulnerability by trying to access an 802.1x multi-auth port after a successful supplicant has authenticated. An exploit could allow the attacker to bypass the 802.1x access controls and obtain access to the network. Cisco Bug IDs: CSCvg69701.
Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
A flaw was found in the Pacemaker configuration tool (pcs). The pcs daemon was allowing expired accounts, and accounts with expired passwords to login when using PAM authentication. Therefore, unprivileged expired accounts that have been denied access could still login.
A vulnerability within the authentication process of Abacus ERP allows a remote attacker to bypass the second authentication factor. This issue affects: Abacus ERP v2022 versions prior to R1 of 2022-01-15; v2021 versions prior to R4 of 2022-01-15; v2020 versions prior to R6 of 2022-01-15; v2019 versions later than R5 (service pack); v2018 versions later than R5 (service pack). This issue does not affect: Abacus ERP v2019 versions prior to R5 of 2020-03-15; v2018 versions prior to R7 of 2020-04-15; v2017 version and prior versions and prior versions.
Crabbox prior to v0.12.0 contains an authentication bypass vulnerability that allows non-admin shared-token callers to impersonate other owners or organizations by spoofing identity headers. Attackers can inject malicious X-Crabbox-Owner and X-Crabbox-Org headers in requests authenticated with a shared token to bypass authorization checks and access owner/org-scoped lease operations belonging to victim accounts.
TYPO3 is an open source PHP based web content management system released under the GNU GPL. In typo3 installations there are always at least two different sites. Eg. first.example.org and second.example.com. In affected versions a session cookie generated for the first site can be reused on the second site without requiring additional authentication. This vulnerability has been addressed in versions 8.7.55, 9.5.44, 10.4.41, 11.5.33, and 12.4.8. Users are advised to upgrade. There are no known workarounds for this vulnerability.
An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. See SEL Service Bulletin dated 2022-11-15 for more details.
A remote code execution vulnerability exists in Microsoft Exchange software when the software fails to properly handle objects in memory, aka 'Microsoft Exchange Memory Corruption Vulnerability'.
Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password.
An issue was discovered in OverIT Geocall 6.3 before build 2:346977. Weak authentication and session management allows an authenticated user to obtain access to the Administrative control panel and execute administrative functions.
Glewlwyd 2.0.0, fixed in 2.6.1 is affected by an incorrect access control vulnerability. One user can attempt to log in as another user without its password.
A authentication bypass vulnerability exists in GitLab CE/EE <v12.3.2, <v12.2.6, and <v12.1.10 in the Salesforce login integration that could be used by an attacker to create an account that bypassed domain restrictions and email verification requirements.
The HomeAutomationGateway service in MiCasaVerde VeraLite with firmware 1.5.408 allows (1) remote attackers to execute arbitrary Lua code via a RunLua action in a request to upnp/control/hag on port 49451 or (2) remote authenticated users to execute arbitrary Lua code via a RunLua action in a request to port_49451/upnp/control/hag.
As of v1.5.0, the default admin password is set to the argocd-server pod name. For insiders with access to the cluster or logs, this issue could be abused for privilege escalation, as Argo has privileged roles. A malicious insider is the most realistic threat, but pod names are not meant to be kept secret and could wind up just about anywhere.
The Account Switcher plugin for WordPress is vulnerable to Privilege Escalation in all versions up to, and including, 1.0.2. This is due to the `rememberLogin` REST API endpoint using a loose comparison (`!=` instead of `!==`) for secret validation at `app/RestAPI.php:111`, combined with no validation that the secret is non-empty. When a target user has never used the "Remember me" feature, their `asSecret` user meta does not exist, causing `get_user_meta()` to return an empty string. An attacker can send an empty `secret` parameter, which passes the comparison (`'' != ''` is `false`), and the endpoint then calls `wp_set_auth_cookie()` for the target user. Additionally, all REST routes use `permission_callback => '__return_true'` with no capability checks. This makes it possible for authenticated attackers, with Subscriber-level access and above, to switch to any user account including Administrator, ultimately granting themselves full administrative privileges.
libspdm is a sample implementation that follows the DMTF SPDM specifications. A vulnerability has been identified in SPDM session establishment in libspdm prior to version 2.3.1. If a device supports both DHE session and PSK session with mutual authentication, the attacker may be able to establish the session with `KEY_EXCHANGE` and `PSK_FINISH` to bypass the mutual authentication. This is most likely to happen when the Requester begins a session using one method (DHE, for example) and then uses the other method's finish (PSK_FINISH in this example) to establish the session. The session hashes would be expected to fail in this case, but the condition was not detected. This issue only impacts the SPDM responder, which supports `KEY_EX_CAP=1 and `PSK_CAP=10b` at same time with mutual authentication requirement. The SPDM requester is not impacted. The SPDM responder is not impacted if `KEY_EX_CAP=0` or `PSK_CAP=0` or `PSK_CAP=01b`. The SPDM responder is not impacted if mutual authentication is not required. libspdm 1.0, 2.0, 2.1, 2.2, 2.3 are all impacted. Older branches are not maintained, but users of the 2.3 branch may receive a patch in version 2.3.2. The SPDM specification (DSP0274) does not contain this vulnerability.
Apache Guacamole 1.2.0 and 1.3.0 do not properly validate responses received from a SAML identity provider. If SAML support is enabled, this may allow a malicious user to assume the identity of another Guacamole user.
eLabFTW is an electronic lab notebook manager for research teams. In versions prior to 4.2.0 there is a vulnerability which allows any authenticated user to gain access to arbitrary accounts by setting a specially crafted email address. This vulnerability impacts all instances that have not set an explicit email domain name allowlist. Note that whereas neither administrators nor targeted users are notified of a change, an attacker will need to control an account. The default settings require administrators to validate newly created accounts. The problem has been patched. Users should upgrade to at least version 4.2.0. For users unable to upgrade enabling an email domain allow list (from Sysconfig panel, Security tab) will completely resolve the issue.
Improper password reset in PAM Module in Devolutions Server 2024.3.10.0 and earlier allows an authenticated user to reuse the oracle user password after check-in due to crash in the password reset functionality.
Improper authentication in the external OAuth authentication flow in Devolutions Server 2026.1.11 and earlier allows an authenticated user to authenticate as other users, including administrators, via reuse of a session code from an external authentication flow.
The debugging routine SCREEN_CLICK(5053) enables a connection to skip the standard device login prompt entirely and directly enter an interactive shell interface.
An Access Control vulnerability exists in Nacos 2.0.3 in the access prompt page; enter username and password, click on login to capture packets and then change the returned package, which lets a malicious user login.
A improper authentication in Fortinet FortiAuthenticator version 6.4.0 allows user to bypass the second factor of authentication via a RADIUS login portal.
authentik is an open-source identity provider. Prior to versions 2025.12.6, 2026.2.4, and 2026.5.1, an attacker with the ability to change a source connection, and an account in one of the configured sources can log into any account. This issue has been patched in versions 2025.12.6, 2026.2.4, and 2026.5.1.