Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
An executable used in Rockwell Automation ThinManager ThinServer can be configured to enable an API feature in the HTTPS Server Settings. This feature is disabled by default. When the API is enabled and handling requests, a path traversal vulnerability exists that allows a remote actor to leverage the privileges of the server’s file system and read arbitrary files stored in it. A malicious user could exploit this vulnerability by executing a path that contains manipulating variables.
In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager ThinServer. An unauthenticated remote attacker can exploit this vulnerability to download arbitrary files on the disk drive where ThinServer.exe is installed.
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR).
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.
Rockwell Automation ThinManager product allows the use of medium strength ciphers. If the client requests an insecure cipher, a malicious actor could potentially decrypt traffic sent between the client and server API.
CVE-2024-40620 IMPACT A vulnerability exists in the affected product due to lack of encryption of sensitive information. The vulnerability results in data being sent between the Console and the Dashboard without encryption, which can be seen in the logs of proxy servers, potentially impacting the data's confidentiality.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable.
A security issue exists within the 5032 16pt Digital Configurable module’s web server. Intercepted session credentials can be used within a 3-minute timeout window, allowing unauthorized users to perform privileged actions.
A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.
CVE-2024-10386 IMPACT An authentication vulnerability exists in the affected product. The vulnerability could allow a threat actor with network access to send crafted messages to the device, potentially resulting in database manipulation.
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.
Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.
A vulnerability in the 802.1x multiple-authentication (multi-auth) feature of Cisco IOS Software could allow an unauthenticated, adjacent attacker to bypass the authentication phase on an 802.1x multi-auth port. The vulnerability is due to a logic change error introduced into the code. An attacker could exploit this vulnerability by trying to access an 802.1x multi-auth port after a successful supplicant has authenticated. An exploit could allow the attacker to bypass the 802.1x access controls and obtain access to the network. Cisco Bug IDs: CSCvg69701.
The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.
CVE-2024-6078 IMPACT An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify data stored in the cloud.
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected. Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
CVE-2024-45823 IMPACT An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication.
The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.
websitebaker prior to and including 2.8.1 has an authentication error in backup module.
An improper implementation logic in Secure Folder prior to SMR Jan-2023 Release 1 allows the Secure Folder container remain unlocked under certain condition.
A vulnerability exists in the Aruba AirWave Management Platform 8.x prior to 8.2 in the management interface of an underlying system component called RabbitMQ, which could let a malicious user obtain sensitive information. This interface listens on TCP port 15672 and 55672
In multiple functions of PasspointXmlUtils.java, there is a possible authentication misconfiguration due to a logic error in the code. This could lead to remote information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-216854451
An improper authentication vulnerability has been reported to affect Android App Qfile. If exploited, this vulnerability allows attackers to compromise app and access information We have already fixed this vulnerability in the following versions of Qfile: Qfile 3.0.0.1105 and later
Improper authentication in OpenBlue Enterprise Manager Data Collector versions prior to 3.2.5.75 allow access to an unauthorized user under certain circumstances.
An issue was discovered on Samsung mobile devices with L(5.0/5.1) and M(6.0) software. There is a SIM Lock bypass. The Samsung ID is SVE-2016-5381 (June 2016).
Improper authentication in Azure Stack allows an unauthorized attacker to disclose information over a network.
IBM Spectrum Copy Data Management 2.2.13 and earlier has weak authentication and password rules and incorrectly handles default credentials for the Spectrum Copy Data Management Admin console. IBM X-Force ID: 214957.
EBM Technologies RISWEB's specific URL path is not properly controlled by permission, allowing attackers to browse specific pages and query sensitive data without login.
Certain NETGEAR devices are affected by mishandling of repeated URL calls. This affects JNR1010v2 before 2017-01-06, WNR614 before 2017-01-06, WNR618 before 2017-01-06, JWNR2000v5 before 2017-01-06, WNR2020 before 2017-01-06, JWNR2010v5 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2020v2 before 2017-01-06, R6220 before 2017-01-06, and WNDR3700v5 before 2017-01-06.
On 2.1.15 version and below of Lider module in LiderAhenk software is leaking it's configurations via an unsecured API. An attacker with an access to the configurations API could get valid LDAP credentials.
A flaw was found in the Network Observability plugin for OpenShift console. Unless the Loki authToken configuration is set to FORWARD mode, authentication is no longer enforced, allowing any user who can connect to the OpenShift Console in an OpenShift cluster to retrieve flows without authentication.
ReCrystallize Server 5.10.0.0 uses a authorization mechanism that relies on the value of a cookie, but it does not bind the cookie value to a session ID. Attackers can easily modify the cookie value, within a browser or by implementing client-side code outside of a browser. Attackers can bypass the authentication mechanism by modifying the cookie to contain an expected value.
WordPress Plugin mb.miniAudioPlayer-an HTML5 audio player for your mp3 files is prone to multiple vulnerabilities, including open proxy and security bypass vulnerabilities because it fails to properly verify user-supplied input. An attacker may leverage these issues to hide attacks directed at a target site from behind vulnerable website or to perform otherwise restricted actions and subsequently download files with the extension mp3, mp4a, wav and ogg from anywhere the web server application has read access to the system. WordPress Plugin mb.miniAudioPlayer-an HTML5 audio player for your mp3 files version 1.7.6 is vulnerable; prior versions may also be affected.
Authentication bypass in Netcomm router models NF20MESH, NF20, and NL1902 allows an unauthenticated user to access content. In order to serve static content, the application performs a check for the existence of specific characters in the URL (.css, .png etc). If it exists, it performs a "fake login" to give the request an active session to load the file and not redirect to the login page.
The bundle management module lacks authentication and control mechanisms in some APIs. Successful exploitation of this vulnerability may affect data confidentiality.
The WMS module lacks the authentication mechanism in some APIs. Successful exploitation of this vulnerability may affect data confidentiality.
A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp)
An authentication bypass vulnerability exists in the web component of the Motorola MR2600. An attacker can exploit this vulnerability to access protected URLs and retrieve sensitive information.
A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2.
The IHwAttestationService interface has a defect in authentication. Successful exploitation of this vulnerability may affect data confidentiality.
An issue was discovered in Foxit E-mail advertising system before September 2018. It allows authentication bypass and information disclosure, related to Interspire Email Marketer.