Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-5328

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-01 Oct, 2023 | 23:31
Updated At-02 Aug, 2024 | 07:52
Rejected At-
Credits

SATO CL4NX-J Plus Cookie improper authentication

A vulnerability classified as critical has been found in SATO CL4NX-J Plus 1.13.2-u455_r2. This affects an unknown part of the component Cookie Handler. The manipulation with the input auth=user,level1,settings; web=true leads to improper authentication. Access to the local network is required for this attack. The exploit has been disclosed to the public and may be used. The identifier VDB-241029 was assigned to this vulnerability.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:01 Oct, 2023 | 23:31
Updated At:02 Aug, 2024 | 07:52
Rejected At:
▼CVE Numbering Authority (CNA)
SATO CL4NX-J Plus Cookie improper authentication

A vulnerability classified as critical has been found in SATO CL4NX-J Plus 1.13.2-u455_r2. This affects an unknown part of the component Cookie Handler. The manipulation with the input auth=user,level1,settings; web=true leads to improper authentication. Access to the local network is required for this attack. The exploit has been disclosed to the public and may be used. The identifier VDB-241029 was assigned to this vulnerability.

Affected Products
Vendor
SATO
Product
CL4NX-J Plus
Modules
  • Cookie Handler
Versions
Affected
  • 1.13.2-u455_r2
Problem Types
TypeCWE IDDescription
CWECWE-287CWE-287 Improper Authentication
Type: CWE
CWE ID: CWE-287
Description: CWE-287 Improper Authentication
Metrics
VersionBase scoreBase severityVector
3.16.3MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
3.06.3MEDIUM
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
2.05.8N/A
AV:A/AC:L/Au:N/C:P/I:P/A:P
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Version: 3.0
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Version: 2.0
Base score: 5.8
Base severity: N/A
Vector:
AV:A/AC:L/Au:N/C:P/I:P/A:P
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

analyst
CV3TR4CK (VulDB User)
Timeline
EventDate
Advisory disclosed2023-10-01 00:00:00
CVE reserved2023-10-01 00:00:00
VulDB entry created2023-10-01 02:00:00
VulDB entry last update2023-10-23 08:25:15
Event: Advisory disclosed
Date: 2023-10-01 00:00:00
Event: CVE reserved
Date: 2023-10-01 00:00:00
Event: VulDB entry created
Date: 2023-10-01 02:00:00
Event: VulDB entry last update
Date: 2023-10-23 08:25:15
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.241029
vdb-entry
technical-description
https://vuldb.com/?ctiid.241029
signature
permissions-required
https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus%20cookie/README.md
exploit
Hyperlink: https://vuldb.com/?id.241029
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.241029
Resource:
signature
permissions-required
Hyperlink: https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus%20cookie/README.md
Resource:
exploit
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.241029
vdb-entry
technical-description
x_transferred
https://vuldb.com/?ctiid.241029
signature
permissions-required
x_transferred
https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus%20cookie/README.md
exploit
x_transferred
Hyperlink: https://vuldb.com/?id.241029
Resource:
vdb-entry
technical-description
x_transferred
Hyperlink: https://vuldb.com/?ctiid.241029
Resource:
signature
permissions-required
x_transferred
Hyperlink: https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus%20cookie/README.md
Resource:
exploit
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:02 Oct, 2023 | 00:15
Updated At:04 Jun, 2024 | 19:18

A vulnerability classified as critical has been found in SATO CL4NX-J Plus 1.13.2-u455_r2. This affects an unknown part of the component Cookie Handler. The manipulation with the input auth=user,level1,settings; web=true leads to improper authentication. Access to the local network is required for this attack. The exploit has been disclosed to the public and may be used. The identifier VDB-241029 was assigned to this vulnerability.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary3.16.3MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Secondary2.05.8MEDIUM
AV:A/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Type: Secondary
Version: 2.0
Base score: 5.8
Base severity: MEDIUM
Vector:
AV:A/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

sato
sato
>>cl4nx-j_plus_firmware>>1.13.2-u455_r2
cpe:2.3:o:sato:cl4nx-j_plus_firmware:1.13.2-u455_r2:*:*:*:*:*:*:*
sato
sato
>>cl4nx-j_plus>>-
cpe:2.3:h:sato:cl4nx-j_plus:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-287Primarycna@vuldb.com
CWE ID: CWE-287
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus%20cookie/README.mdcna@vuldb.com
Third Party Advisory
https://vuldb.com/?ctiid.241029cna@vuldb.com
Third Party Advisory
https://vuldb.com/?id.241029cna@vuldb.com
Third Party Advisory
Hyperlink: https://github.com/CV3TR4CK/CV3Cyb3R/blob/main/2023/SATO%20CL4NX-J%20Plus%20cookie/README.md
Source: cna@vuldb.com
Resource:
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.241029
Source: cna@vuldb.com
Resource:
Third Party Advisory
Hyperlink: https://vuldb.com/?id.241029
Source: cna@vuldb.com
Resource:
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

85Records found

CVE-2020-25183
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8||HIGH
EPSS-0.14% / 35.19%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 19:18
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink Smart Improper Authentication

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.

Action-Not Available
Vendor-medtronicMedtronic
Product-mycarelink_smart_model_25000_firmwaremycarelink_smart_model_25000Smart Model 25000 Patient Reader
CWE ID-CWE-287
Improper Authentication
CVE-2020-24579
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-87.79% / 99.44%
||
7 Day CHG~0.00%
Published-22 Dec, 2020 | 18:04
Updated-04 Aug, 2024 | 15:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DSL-2888A devices with firmware prior to AU_2.31_V1.1.47ae55. An unauthenticated attacker could bypass authentication to access authenticated pages and functionality.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl2888adsl2888a_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2023-37284
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-0.02% / 3.65%
||
7 Day CHG~0.00%
Published-06 Sep, 2023 | 09:24
Updated-26 Sep, 2024 | 20:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper authentication vulnerability in Archer C20 firmware versions prior to 'Archer C20(JP)_V1_230616' allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command via a crafted request to bypass authentication.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-archer_c20archer_c20_firmwareArcher C20archer_c20_firmware
CWE ID-CWE-287
Improper Authentication
CVE-2020-16222
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.08% / 23.38%
||
7 Day CHG~0.00%
Published-11 Sep, 2020 | 12:55
Updated-04 Aug, 2024 | 13:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Philips Patient Monitoring Devices Improper Authentication

In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.

Action-Not Available
Vendor-Philips
Product-performancebridge_focal_pointpatient_information_center_ixPatient Information Center iX (PICiX)PerformanceBridge Focal Point
CWE ID-CWE-287
Improper Authentication
CVE-2020-15055
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.09% / 27.16%
||
7 Day CHG~0.00%
Published-07 Aug, 2020 | 21:16
Updated-04 Aug, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TP-Link USB Network Server TL-PS310U devices before 2.079.000.t0210 allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.

Action-Not Available
Vendor-n/aTP-Link Systems Inc.
Product-tl-ps310u_firmwaretl-ps310un/a
CWE ID-CWE-287
Improper Authentication
CVE-2020-15063
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.09% / 27.16%
||
7 Day CHG~0.00%
Published-07 Aug, 2020 | 21:26
Updated-04 Aug, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DIGITUS DA-70254 4-Port Gigabit Network Hub 2.073.000.E0008 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.

Action-Not Available
Vendor-digitusn/a
Product-da-70254_firmwareda-70254n/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-18720
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.16% / 37.49%
||
7 Day CHG~0.00%
Published-24 Apr, 2020 | 13:15
Updated-05 Aug, 2024 | 21:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by authentication bypass. This affects D6200 before 1.1.00.24, R6700v2 before 1.1.0.42, R6800 before 1.1.0.42, and R6900v2 before 1.1.0.42.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d6200_firmwarer6800r6900_firmwarer6900r6700d6200r6700_firmwarer6800_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2023-28727
Matching Score-4
Assigner-Panasonic Holdings Corporation
ShareView Details
Matching Score-4
Assigner-Panasonic Holdings Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.01% / 0.86%
||
7 Day CHG~0.00%
Published-31 Mar, 2023 | 06:30
Updated-12 Feb, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Panasonic AiSEG2 versions 2.00J through 2.93A allows adjacent attackers bypass authentication due to mishandling of X-Forwarded-For headers.

Action-Not Available
Vendor-panasonicPanasonic
Product-aiseg2aiseg2_firmwareAiSEG2
CWE ID-CWE-305
Authentication Bypass by Primary Weakness
CWE ID-CWE-287
Improper Authentication
CVE-2023-29117
Matching Score-4
Assigner-Automotive Security Research Group (ASRG)
ShareView Details
Matching Score-4
Assigner-Automotive Security Research Group (ASRG)
CVSS Score-8.8||HIGH
EPSS-0.05% / 16.75%
||
7 Day CHG~0.00%
Published-05 Nov, 2024 | 15:14
Updated-08 Nov, 2024 | 16:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authentication Bypass in JuiceBox Web Manager interface

Waybox Enel X web management API authentication could be bypassed and provide administrator’s privileges over the Waybox system.

Action-Not Available
Vendor-enelxEnel Xenel_x
Product-waybox_prowaybox_pro_firmwareJuiceBox Pro 3.0 22kW Cellularjuicebox_pro3.0_22kw_cellular
CWE ID-CWE-287
Improper Authentication
CVE-2022-22990
Matching Score-4
Assigner-Western Digital
ShareView Details
Matching Score-4
Assigner-Western Digital
CVSS Score-7.8||HIGH
EPSS-1.60% / 80.93%
||
7 Day CHG~0.00%
Published-13 Jan, 2022 | 20:27
Updated-03 Aug, 2024 | 03:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Limited authentication bypass vulnerability on Western Digital My Cloud devices

A limited authentication bypass vulnerability was discovered that could allow an attacker to achieve remote code execution and escalate privileges on the My Cloud devices. Addressed this vulnerability by changing access token validation logic and rewriting rule logic on PHP scripts.

Action-Not Available
Vendor-Western Digital Corp.
Product-my_cloud_dl2100wd_cloudmy_cloudmy_cloud_ex4100my_cloud_ex2_ultramy_cloud_osmy_cloud_mirror_gen_2my_cloud_pr2100my_cloud_dl4100my_cloud_ex2100my_cloud_pr4100My Cloud
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-697
Incorrect Comparison
CVE-2020-11551
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.30% / 52.57%
||
7 Day CHG~0.00%
Published-18 May, 2020 | 15:45
Updated-04 Aug, 2024 | 11:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on NETGEAR Orbi Tri-Band Business WiFi Add-on Satellite (SRS60) AC3000 V2.5.1.106, Outdoor Satellite (RBS50Y) V2.5.1.106, and Pro Tri-Band Business WiFi Router (SRR60) AC3000 V2.5.1.106. The administrative SOAP interface allows an unauthenticated remote write of arbitrary Wi-Fi configuration data such as authentication details (e.g., the Web-admin password), network settings, DNS settings, system administration interface configuration, etc.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs50y_firmwaresrr60srs60_firmwaresrs60rbs50ysrr60_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-330
Use of Insufficiently Random Values
CVE-2017-18743
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.16% / 37.49%
||
7 Day CHG~0.00%
Published-23 Apr, 2020 | 15:38
Updated-05 Aug, 2024 | 21:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by authentication bypass. This affects R6300v2 before 1.0.4.8, R6400 before 1.0.1.20, R6700 before 1.0.1.20, R6900 before 1.0.1.20, R7000 before 1.0.7.10, R7100LG before V1.0.0.32, R7300DST before 1.0.0.52, R7900 before 1.0.1.16, R8000 before 1.0.3.36, R8300 before 1.0.2.94, R8500 before 1.0.2.94, WNDR3400v3 before 1.0.1.12, and WNR3500Lv2 before 1.2.0.40.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8500wndr3400_firmwarer6700r8300_firmwarer8000r6400_firmwarer7000wnr3500l_firmwarer7100lgr7900r6900wndr3400wnr3500lr8300r7100lg_firmwarer7300dst_firmwarer8500_firmwarer6900_firmwarer7900_firmwarer7000_firmwarer6300r7300dstr6400r6300_firmwarer6700_firmwarer8000_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-18732
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.20% / 42.12%
||
7 Day CHG+0.13%
Published-23 Apr, 2020 | 16:23
Updated-05 Aug, 2024 | 21:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by authentication bypass. This affects R6300v2 before 1.0.4.8, PLW1000v2 before 1.0.0.14, and PLW1010v2 before 1.0.0.14.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-plw1000_firmwareplw1010plw1010_firmwarer6300r6300_firmwareplw1000n/a
CWE ID-CWE-287
Improper Authentication
CVE-2019-7226
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.46% / 63.28%
||
7 Day CHG~0.00%
Published-27 Jun, 2019 | 15:52
Updated-04 Aug, 2024 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.

Action-Not Available
Vendor-n/aABB
Product-pb610_panel_builder_600pb610_panel_builder_600_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2019-5964
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-0.16% / 37.66%
||
7 Day CHG-0.01%
Published-05 Jul, 2019 | 13:20
Updated-04 Aug, 2024 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

iDoors Reader 2.10.17 and earlier allows an attacker on the same network segment to bypass authentication to access the management console and operate the product via unspecified vectors.

Action-Not Available
Vendor-idoorsA.T.WORKS, Inc.
Product-idoors_readeriDoors Reader
CWE ID-CWE-287
Improper Authentication
CVE-2019-5218
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-8.8||HIGH
EPSS-0.10% / 28.66%
||
7 Day CHG~0.00%
Published-29 Nov, 2019 | 19:51
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is an insufficient authentication vulnerability in Huawei Band 2 and Honor Band 3. The band does not sufficiently authenticate the device try to connect to it in certain scenario. Successful exploit could allow the attacker to spoof then connect to the band.

Action-Not Available
Vendor-n/aHuawei Technologies Co., Ltd.
Product-band_3_firmwareband_2_firmwareband_2band_3Huawei Band 2, Honor Band 3
CWE ID-CWE-287
Improper Authentication
CVE-2023-25556
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.3||HIGH
EPSS-0.12% / 32.23%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 17:03
Updated-05 Feb, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.

Action-Not Available
Vendor-Schneider Electric SE
Product-merten_instabus_tastermodul_2fach_system_mmerten_instabus_tastermodul_1fach_system_mmerten_tasterschnittstelle_4fach_plus_firmwaremerten_instabus_tastermodul_2fach_system_m_firmwaremerten_knx_uni-dimmaktor_ll_reg-k\/2x230\/300_wmerten_jalousie-\/schaltaktor_reg-k\/8x\/16x\/10_m._hbmerten_instabus_tastermodul_1fach_system_m_firmwaremerten_knx_argus_180\/2\,20m_up_systemmerten_knx_schaltakt.2x6a_up_m.2_eing._firmwaremerten_tasterschnittstelle_4fach_plusmerten_knx_argus_180\/2\,20m_up_system_firmwaremerten_jalousie-\/schaltaktor_reg-k\/8x\/16x\/10_m._hb_firmwaremerten_knx_schaltakt.2x6a_up_m.2_eing.merten_knx_uni-dimmaktor_ll_reg-k\/2x230\/300_w_firmwareMerten INSTABUS Tastermodul 1fach System M 625199Merten KNX Uni-Dimmaktor LL REG-K/2x230/300 W MEG6710-0002Merten INSTABUS Tastermodul 2fach System M 625299Merten KNX Schaltakt.2x6A UP m.2 Eing. MEG6003-0002Merten KNX ARGUS 180/2,20M UP SYSTEM 631725Merten Tasterschnittstelle 4fach plus 670804Merten Jalousie-/Schaltaktor REG-K/8x/16x/10 m. HB 649908
CWE ID-CWE-287
Improper Authentication
CVE-2023-25946
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-0.03% / 8.40%
||
7 Day CHG~0.00%
Published-23 May, 2023 | 00:00
Updated-31 Jan, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Authentication bypass vulnerability in Qrio Lock (Q-SL2) firmware version 2.0.9 and earlier allows a network-adjacent attacker to analyze the product's communication data and conduct an arbitrary operation under certain conditions.

Action-Not Available
Vendor-qrioQrio, inc.
Product-q-sl2_firmwareq-sl2Qrio Lock (Q-SL2)
CWE ID-CWE-863
Incorrect Authorization
CWE ID-CWE-287
Improper Authentication
CVE-2017-2871
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.6||CRITICAL
EPSS-0.19% / 41.14%
||
7 Day CHG~0.00%
Published-17 Apr, 2018 | 20:00
Updated-16 Sep, 2024 | 20:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Insufficient security checks exist in the recovery procedure used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.43. An attacker who is in the same subnetwork of the camera or has remote administrator access can fully compromise the device by performing a firmware recovery using a custom image.

Action-Not Available
Vendor-foscamTalos (Cisco Systems, Inc.)
Product-c1_firmwarec1Foscam
CWE ID-CWE-287
Improper Authentication
CVE-2021-34977
Matching Score-4
Assigner-Zero Day Initiative
ShareView Details
Matching Score-4
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-0.50% / 64.78%
||
7 Day CHG~0.00%
Published-13 Jan, 2022 | 21:44
Updated-04 Aug, 2024 | 00:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7000 1.0.11.116_10.2.100 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of SOAP requests. The issue results from the lack of proper authentication verification before performing a password reset. An attacker can leverage this vulnerability to reset the admin password. Was ZDI-CAN-13483.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-r7000_firmwarer7000R7000
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CWE ID-CWE-287
Improper Authentication
CVE-2019-19598
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.22%
||
7 Day CHG~0.00%
Published-05 Dec, 2019 | 03:07
Updated-05 Aug, 2024 | 02:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DAP-1860 devices before v1.04b03 Beta allow access to administrator functions without authentication via the HNAP_AUTH header timestamp value. In HTTP requests, part of the HNAP_AUTH header is the timestamp used to determine the time when the user sent the request. If this value is equal to the value stored in the device's /var/hnap/timestamp file, the request will pass the HNAP_AUTH check function.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dap-1860dap-1860_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2016-6541
Matching Score-4
Assigner-CERT/CC
ShareView Details
Matching Score-4
Assigner-CERT/CC
CVSS Score-8.8||HIGH
EPSS-0.95% / 75.40%
||
7 Day CHG~0.00%
Published-06 Jul, 2018 | 21:00
Updated-06 Aug, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TrackR Bravo device allows unauthenticated pairing, which enables unauthenticated connected applications to write to various device attributes

TrackR Bravo device allows unauthenticated pairing, which enables unauthenticated connected applications to write to various device attributes. Updated apps, version 5.1.6 for iOS and 2.2.5 for Android, have been released by the vendor to address the vulnerabilities in CVE-2016-6538, CVE-2016-6539, CVE-2016-6540 and CVE-2016-6541.

Action-Not Available
Vendor-thetrackrTrackR
Product-trackr_bravo_firmwaretrackr_bravoBravo Mobile Application
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-287
Improper Authentication
CVE-2020-8713
Matching Score-4
Assigner-Intel Corporation
ShareView Details
Matching Score-4
Assigner-Intel Corporation
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.61%
||
7 Day CHG~0.00%
Published-13 Aug, 2020 | 02:53
Updated-04 Aug, 2024 | 10:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper authentication for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.

Action-Not Available
Vendor-n/aIntel Corporation
Product-compute_module_hns2600bpblc24rserver_system_r1304wt2gsrserver_system_lsvrp_firmwarecompute_module_hns2600tpfrserver_system_r2208wt2ysrserver_board_s2600wftserver_system_r2312wftzsrserver_system_r1000sp_firmwareserver_board_s2600kprserver_system_r1304wf0ysserver_system_r1304wf0ysrserver_system_r1304sposhbnserver_board_s2600kpfserver_system_lsvrp4304es6xx1server_board_s2600cwtserver_board_s2600kpcompute_module_hns2600bpbserver_board_s2600stbcompute_module_hns2600kprserver_system_r1208wttgsrserver_board_s2600cw2rserver_board_s2600wfqrcompute_module_hns2600tp24rserver_system_r2308wftzsserver_system_r2308wttysserver_system_r1000wf_firmwareserver_board_s2600wftrserver_system_r1304wt2gscompute_module_hns2600tprserver_system_r2208wf0zsserver_board_s2600kptrserver_board_s2600st_firmwareserver_system_r1208sposhorrcompute_module_hns2600tp_firmwareserver_board_s1200splserver_board_s2600cw2srserver_system_r1208wt2gsserver_board_s2600tpserver_system_r2208wttyc1rserver_board_s2600stqrcompute_module_hns2600bpblc24server_board_s2600cw2scompute_module_hns2600kp_firmwareserver_system_vrn2208wfaf83server_board_s2600cwtrserver_board_s1200spsserver_board_s2600bpqserver_system_r2208wt2ysserver_system_r1208wttgsserver_system_r1304wttgsserver_system_r2208wttysrserver_system_r1304sposhbnrserver_system_r2208wfqzsrserver_board_s2600tpfserver_board_s2600cwtsserver_system_lr1304sp_firmwareserver_system_r2312wf0nprserver_board_s2600wttrserver_board_s2600wt2server_system_r1208wfqysrserver_system_vrn2208wfhy6server_board_s2600stqserver_system_r2224wftzsserver_board_s2600wf0rserver_system_r2208wfqzsserver_system_nb2208wfqnfviserver_system_r2208wftzsserver_system_r2224wftzsrcompute_module_hns2600bpq24rserver_system_r2224wttysserver_board_s1200sp_firmwareserver_system_lr1304spcfg1rserver_system_lr1304spcfg1server_system_mcb2208wfaf5compute_module_hns2600bps24server_board_s2600bpsserver_board_s2600wt_firmwareserver_board_s2600bpqrserver_system_r2000wt_firmwareserver_system_r1208wt2gsrserver_system_vrn2208wfaf82compute_module_hns2600bpb24rserver_system_r1208wftysserver_system_r2000wf_firmwareserver_board_s2600cwserver_system_r2308wftzsrserver_system_lnetcnt3ycompute_module_s2600tp_firmwarecompute_module_hns2600bps24rserver_system_r1304wftysrserver_system_lsvrp4304es6xxrcompute_module_hns2600bpsrserver_board_s2600wt2rserver_system_mcb2208wfhy2server_board_s2600tpfrcompute_module_hns2600bpblcrserver_board_s2600cwtsrserver_system_r2224wfqzsserver_system_r2308wttysrcompute_module_hns2600tpfserver_system_r2312wftzsserver_system_vrn2208wfaf81server_board_s2600stbrcompute_module_hns2600bpqrserver_system_r2224wttysrserver_system_r2312wttyscompute_module_hns2600bpbrserver_system_r1208sposhorserver_board_s2600bp_firmwareserver_board_s2600bpbrserver_system_r1000wt_firmwareserver_board_s2600wttserver_board_s2600wf0compute_module_hns2600kpserver_system_r2312wfqzsserver_system_mcb2208wfaf6server_system_r1304wftysserver_system_r2208wttysserver_system_r1304sposhorrserver_system_vrn2208waf6compute_module_hns2600bp_firmwareserver_system_r1304sposhorcompute_module_hns2600tpcompute_module_hns2600kpfrcompute_module_hns2600bpqserver_board_s1200sporserver_board_s2600bpbserver_system_mcb2208wfaf4server_board_s1200splrserver_system_lr1304spcfsgx1compute_module_hns2600kpfcompute_module_hns2600bpblcserver_system_r2208wttyc1server_board_s2600cw2server_board_s1200sposerver_board_s2600wfqserver_board_s2600bpsrserver_system_r2312wf0npserver_system_r1304wttgsrserver_system_r2312wttysrserver_board_s2600kp_firmwareserver_system_r1208wttgsbppserver_board_s1200spsrcompute_module_hns2600bpsserver_system_r2208wf0zsrserver_board_s2600kpfrcompute_module_hns2600bpb24server_system_r2208wftzsrserver_system_r1208wftysrserver_board_s2600tprcompute_module_hns2600tp24srserver_board_s2600wf_firmwarecompute_module_hns2600bpq24Intel(R) Server Boards, Server Systems and Compute Modules Advisory
CWE ID-CWE-287
Improper Authentication
CVE-2020-35785
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.3||HIGH
EPSS-0.13% / 32.77%
||
7 Day CHG~0.00%
Published-29 Dec, 2020 | 23:40
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR DGN2200v1 devices before v1.0.0.60 mishandle HTTPd authentication (aka PSV-2020-0363, PSV-2020-0364, and PSV-2020-0365).

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-dgn2200_firmwaredgn2200n/a
CWE ID-CWE-287
Improper Authentication
CVE-2020-35231
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.09%
||
7 Day CHG~0.00%
Published-10 Mar, 2021 | 18:14
Updated-04 Aug, 2024 | 17:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The NSDP protocol implementation on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices was affected by an authentication issue that allows an attacker to bypass access controls and obtain full control of the device.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-jgs516pe_firmwaregs116e_firmwaregs116ejgs516pen/a
CWE ID-CWE-287
Improper Authentication
CVE-2019-10964
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.1||HIGH
EPSS-0.45% / 62.78%
||
7 Day CHG~0.00%
Published-28 Jun, 2019 | 20:58
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

Action-Not Available
Vendor-medtronicMedtronic
Product-minimed_paradigm_722minimed_paradigm_512minimed_paradigm_veo_554minimed_paradigm_523kminimed_paradigm_veo_754cmminimed_paradigm_723k_firmwareminimed_paradigm_veo_754cm_firmwareminimed_paradigm_712e_firmwareminimed_paradigm_523minimed_paradigm_veo_554cmminimed_paradigm_511minimed_paradigm_723minimed_paradigm_722_firmwareminimed_paradigm_712eminimed_paradigm_723_firmwareminimed_paradigm_522k_firmwareminimed_paradigm_veo_754minimed_paradigm_715_firmwareminimed_paradigm_723kminimed_508_firmwareminimed_paradigm_715minimed_paradigm_veo_754_firmwareminimed_paradigm_523k_firmwareminimed_paradigm_512_firmwareminimed_paradigm_523_firmwareminimed_paradigm_veo_554_firmwareminimed_paradigm_712_firmwareminimed_paradigm_veo_554cm_firmwareminimed_paradigm_522minimed_paradigm_722kminimed_508minimed_paradigm_722k_firmwareminimed_paradigm_515minimed_paradigm_511_firmwareminimed_paradigm_712minimed_paradigm_515_firmwareminimed_paradigm_522kminimed_paradigm_522_firmwareMiniMed Paradigm 512/712 pumpsMiniMed 508 pumpMiniMed Paradigm 515/715 pumpsMiniMed Paradigm 511 pumpMiniMed Paradigm 522K/722K pumpsMiniMed Paradigm 523/723 pumpsMiniMed Paradigm 523K/723K pumpsMiniMed Paradigm 522/722 pumpsMiniMed Paradigm Veo 554/754 pumpsMiniMed Paradigm Veo 554CM/754CM pumpsMiniMed Paradigm 712E pump
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-863
Incorrect Authorization
CVE-2022-42463
Matching Score-4
Assigner-OpenHarmony
ShareView Details
Matching Score-4
Assigner-OpenHarmony
CVSS Score-8.3||HIGH
EPSS-0.01% / 0.80%
||
7 Day CHG~0.00%
Published-14 Oct, 2022 | 14:40
Updated-14 May, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Softbus_server in communication subsystem has a authenication bypass vulnerability in a callback handler function. Attackers can launch attacks on distributed networks by sending Bluetooth rfcomm packets to any remote device and executing arbitrary co ...

OpenHarmony-v3.1.2 and prior versions have an authenication bypass vulnerability in a callback handler function of Softbus_server in communication subsystem. Attackers can launch attacks on distributed networks by sending Bluetooth rfcomm packets to any remote device and executing arbitrary commands.

Action-Not Available
Vendor-OpenHarmony (OpenAtom Foundation)
Product-openharmonyOpenHarmony
CWE ID-CWE-287
Improper Authentication
CVE-2015-10083
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.06% / 19.00%
||
7 Day CHG~0.00%
Published-21 Feb, 2023 | 15:00
Updated-06 Aug, 2024 | 08:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
harrystech Dynosaur-Rails application_controller.rb basic_auth improper authentication

A vulnerability has been found in harrystech Dynosaur-Rails and classified as critical. Affected by this vulnerability is the function basic_auth of the file app/controllers/application_controller.rb. The manipulation leads to improper authentication. This product does not use versioning. This is why information about affected and unaffected releases are unavailable. The patch is named 04b223813f0e336aab50bff140d0f5889c31dbec. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-221503.

Action-Not Available
Vendor-harrysharrystech
Product-dynosaur-railsDynosaur-Rails
CWE ID-CWE-287
Improper Authentication
CVE-2018-11478
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.60%
||
7 Day CHG~0.00%
Published-30 May, 2018 | 21:00
Updated-05 Aug, 2024 | 08:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Vgate iCar 2 Wi-Fi OBD2 Dongle devices. The OBD port is used to receive measurement data and debug information from the car. This on-board diagnostics feature can also be used to send commands to the car (different for every vendor / car product line / car). No authentication is needed, which allows attacks from the local Wi-Fi network.

Action-Not Available
Vendor-vgaten/a
Product-icar_2_wi-fi_obd2_firmwareicar_2_wi-fi_obd2n/a
CWE ID-CWE-287
Improper Authentication
CVE-2024-41589
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.07% / 22.52%
||
7 Day CHG~0.00%
Published-03 Oct, 2024 | 00:00
Updated-04 Oct, 2024 | 13:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DrayTek Vigor310 devices through 4.3.2.6 use unencrypted HTTP for authentication requests.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-n/avigor3910_firmware
CWE ID-CWE-287
Improper Authentication
CVE-2020-8708
Matching Score-4
Assigner-Intel Corporation
ShareView Details
Matching Score-4
Assigner-Intel Corporation
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.42%
||
7 Day CHG~0.00%
Published-13 Aug, 2020 | 02:23
Updated-04 Aug, 2024 | 10:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper authentication for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.

Action-Not Available
Vendor-n/aIntel Corporation
Product-compute_module_hns2600bpblc24rserver_system_r1304wt2gsrserver_system_lsvrp_firmwarecompute_module_hns2600tpfrserver_system_r2208wt2ysrserver_board_s2600wftserver_system_r2312wftzsrserver_system_r1000sp_firmwareserver_board_s2600kprserver_system_r1304wf0ysserver_system_r1304wf0ysrserver_system_r1304sposhbnserver_board_s2600kpfserver_system_lsvrp4304es6xx1server_board_s2600cwtserver_board_s2600kpcompute_module_hns2600bpbserver_board_s2600stbcompute_module_hns2600kprserver_system_r1208wttgsrserver_board_s2600cw2rserver_board_s2600wfqrcompute_module_hns2600tp24rserver_system_r2308wftzsserver_system_r2308wttysserver_system_r1000wf_firmwareserver_board_s2600wftrserver_system_r1304wt2gscompute_module_hns2600tprserver_system_r2208wf0zsserver_board_s2600kptrserver_board_s2600st_firmwareserver_system_r1208sposhorrcompute_module_hns2600tp_firmwareserver_board_s1200splserver_board_s2600cw2srserver_system_r1208wt2gsserver_board_s2600tpserver_system_r2208wttyc1rserver_board_s2600stqrcompute_module_hns2600bpblc24server_board_s2600cw2scompute_module_hns2600kp_firmwareserver_system_vrn2208wfaf83server_board_s2600cwtrserver_board_s1200spsserver_board_s2600bpqserver_system_r2208wt2ysserver_system_r1208wttgsserver_system_r1304wttgsserver_system_r2208wttysrserver_system_r1304sposhbnrserver_system_r2208wfqzsrserver_board_s2600tpfserver_board_s2600cwtsserver_system_lr1304sp_firmwareserver_system_r2312wf0nprserver_board_s2600wttrserver_board_s2600wt2server_system_r1208wfqysrserver_system_vrn2208wfhy6server_board_s2600stqserver_system_r2224wftzsserver_board_s2600wf0rserver_system_r2208wfqzsserver_system_nb2208wfqnfviserver_system_r2208wftzsserver_system_r2224wftzsrcompute_module_hns2600bpq24rserver_system_r2224wttysserver_board_s1200sp_firmwareserver_system_lr1304spcfg1rserver_system_lr1304spcfg1server_system_mcb2208wfaf5compute_module_hns2600bps24server_board_s2600bpsserver_board_s2600wt_firmwareserver_board_s2600bpqrserver_system_r2000wt_firmwareserver_system_r1208wt2gsrserver_system_vrn2208wfaf82compute_module_hns2600bpb24rserver_system_r1208wftysserver_system_r2000wf_firmwareserver_board_s2600cwserver_system_r2308wftzsrserver_system_lnetcnt3ycompute_module_s2600tp_firmwarecompute_module_hns2600bps24rserver_system_r1304wftysrserver_system_lsvrp4304es6xxrcompute_module_hns2600bpsrserver_board_s2600wt2rserver_system_mcb2208wfhy2server_board_s2600tpfrcompute_module_hns2600bpblcrserver_board_s2600cwtsrserver_system_r2224wfqzsserver_system_r2308wttysrcompute_module_hns2600tpfserver_system_r2312wftzsserver_system_vrn2208wfaf81server_board_s2600stbrcompute_module_hns2600bpqrserver_system_r2224wttysrserver_system_r2312wttyscompute_module_hns2600bpbrserver_system_r1208sposhorserver_board_s2600bp_firmwareserver_board_s2600bpbrserver_system_r1000wt_firmwareserver_board_s2600wttserver_board_s2600wf0compute_module_hns2600kpserver_system_r2312wfqzsserver_system_mcb2208wfaf6server_system_r1304wftysserver_system_r2208wttysserver_system_r1304sposhorrserver_system_vrn2208waf6compute_module_hns2600bp_firmwareserver_system_r1304sposhorcompute_module_hns2600tpcompute_module_hns2600kpfrcompute_module_hns2600bpqserver_board_s1200sporserver_board_s2600bpbserver_system_mcb2208wfaf4server_board_s1200splrserver_system_lr1304spcfsgx1compute_module_hns2600kpfcompute_module_hns2600bpblcserver_system_r2208wttyc1server_board_s2600cw2server_board_s1200sposerver_board_s2600wfqserver_board_s2600bpsrserver_system_r2312wf0npserver_system_r1304wttgsrserver_system_r2312wttysrserver_board_s2600kp_firmwareserver_system_r1208wttgsbppserver_board_s1200spsrcompute_module_hns2600bpsserver_system_r2208wf0zsrserver_board_s2600kpfrcompute_module_hns2600bpb24server_system_r2208wftzsrserver_system_r1208wftysrserver_board_s2600tprcompute_module_hns2600tp24srserver_board_s2600wf_firmwarecompute_module_hns2600bpq24Intel(R) Server Boards, Server Systems and Compute Modules Advisory
CWE ID-CWE-287
Improper Authentication
CVE-2020-8861
Matching Score-4
Assigner-Zero Day Initiative
ShareView Details
Matching Score-4
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-3.28% / 86.67%
||
7 Day CHG~0.00%
Published-22 Feb, 2020 | 00:00
Updated-04 Aug, 2024 | 10:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DAP-1330 1.10B01 BETA Wi-Fi range extenders. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of HNAP login requests. The issue results from the lack of proper handling of cookies. An attacker can leverage this vulnerability to execute arbitrary code on the router. Was ZDI-CAN-9554.

Action-Not Available
Vendor-D-Link Corporation
Product-dap-1330_firmwaredap-1330DAP-1330
CWE ID-CWE-303
Incorrect Implementation of Authentication Algorithm
CWE ID-CWE-287
Improper Authentication
CVE-2020-15059
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.09% / 27.16%
||
7 Day CHG~0.00%
Published-07 Aug, 2020 | 21:22
Updated-04 Aug, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Lindy 42633 4-Port USB 2.0 Gigabit Network Server 2.078.000 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.

Action-Not Available
Vendor-lindy-internationaln/a
Product-42633_firmware42633n/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-18772
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.16% / 37.49%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 14:47
Updated-05 Aug, 2024 | 21:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by authentication bypass. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6120 before 1.0.0.32, EX6130 before 1.0.0.16, R6300v2 before 1.0.4.12, R6700 before 1.0.1.26, R6900 before 1.0.1.22, R7000 before 1.0.9.6, R7300DST before 1.0.0.52, R7900 before 1.0.1.12, R8000 before 1.0.3.24, R8500 before 1.0.2.74, and WNR2000v2 before 1.2.0.8.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8500ex6130_firmwarer6700r8000r7000ex3800_firmwarewnr2000_firmwarer7900r6900ex3700r8500_firmwarer7300dst_firmwarer6900_firmwareex3800r7900_firmwarer7000_firmwareex3700_firmwarer6300r7300dstex6120r6300_firmwarer6700_firmwareex6130ex6120_firmwarewnr2000r8000_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-18733
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.16% / 37.49%
||
7 Day CHG~0.00%
Published-23 Apr, 2020 | 16:22
Updated-05 Aug, 2024 | 21:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by authentication bypass. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D8500 before 1.0.3.29, R6250 before 1.0.4.8, R6400 before 1.0.1.22, R6400v2 before 1.0.2.32, R7100LG before 1.0.0.32, R7300DST before 1.0.0.52, R8300 before 1.0.2.94, and R8500 before 1.0.2.100.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8500d8500r8300_firmwarer6400_firmwarer7100lgd6400d6220r8300r7100lg_firmwarer7300dst_firmwarer8500_firmwared6400_firmwarer7300dstd6220_firmwarer6400d8500_firmwarer6250_firmwarer6250n/a
CWE ID-CWE-287
Improper Authentication
  • Previous