Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory.
The Meatmeet Pro was found to be shipped with hardcoded Wi-Fi credentials in the firmware, for the test network it was developed on. If an attacker retrieved this, and found the physical location of the Wi-Fi network, they could gain unauthorized access to the Wi-Fi network of the vendor. Additionally, if an attacker were located in close physical proximity to the device when it was first set up, they may be able to force the device to auto-connect to an attacker-controlled access point by setting the SSID and password to the same as which was found in the firmware file.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.
Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain SuperUser access to the device.
An authentication bypass vulnerability exists in the web interface /action/factory* functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP header can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.
A vulnerability, which was classified as critical, has been found in taoeffect Empress. Affected by this issue is some unknown functionality. The manipulation leads to use of hard-coded password. The patch is identified as 557e177d8a309d6f0f26de46efb38d43e000852d. It is recommended to apply a patch to fix this issue. VDB-217154 is the identifier assigned to this vulnerability.
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
EMV DiskXtender 6.20.060 has a hard-coded login and password, which allows remote attackers to bypass authentication via the RPC interface.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials.
ASUS WebStorage has a hardcoded API Token in the APP source code. An unauthenticated remote attacker can use this token to establish connections with the server and carry out login attempts to general user accounts. A successful login to a general user account allows the attacker to access, modify or delete this user account information.
Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter.
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
IBM Security Identity Manager 7.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171511.
Rakuten Casa version AP_F_V1_4_1 or AP_F_V2_0_0 uses a hard-coded credential which may allow a remote unauthenticated attacker to log in with the root privilege and perform an arbitrary operation.
HCL AppScan Standard Edition 9.0.3.13 and earlier uses hard-coded credentials which can be exploited by attackers to get unauthorized access to the system.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 contains multiple hard coded credentials for the Telnet and SSH interfaces.
Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses.
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.
FaceSentry Access Control System 6.4.8 contains a critical authentication vulnerability with hard-coded SSH credentials for the wwwuser account. Attackers can leverage the insecure sudoers configuration to escalate privileges and gain root access by executing sudo commands without authentication.
mcollective has a default password set at install
Trend Micro ServerProtect 6.0/5.8 Information Server uses a static credential to perform authentication when a specific command is typed in the console. An unauthenticated remote attacker with access to the Information Server could exploit this to register to the server and perform authenticated actions.
Goldshell ASIC Miners v2.1.x was discovered to contain hardcoded credentials which allow attackers to remotely connect via the SSH protocol (port 22).
IZON IP 2.0.2: hard-coded password vulnerability
Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files.
A vulnerability in Cisco Smart Licensing Utility (CSLU) could allow an unauthenticated, remote attacker to log into an affected system by using a static administrative credential. This vulnerability is due to an undocumented static user credential for an administrative account. An attacker could exploit this vulnerability by using the static credentials to login to the affected system. A successful exploit could allow the attacker to login to the affected system with administrative rights over the CSLU application API.
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
NUUO v03.11.00 was discovered to contain access control issue.
Baicells Nova436Q and Neutrino 430 devices with firmware through QRTB 2.7.8 have hardcoded credentials that are easily discovered, and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)
Home Owners Collection Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel.
Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
A vulnerability in Cisco Integrated Management Controller (IMC) Supervisor, Cisco UCS Director, and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to log in to the CLI of an affected system by using the SCP User account (scpuser), which has default user credentials. The vulnerability is due to the presence of a documented default account with an undocumented default password and incorrect permission settings for that account. Changing the default password for this account is not enforced during the installation of the product. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to execute arbitrary commands with the privileges of the scpuser account. This includes full read and write access to the system's database.
Certain builds of NEC SV9100 software could allow an unauthenticated, remote attacker to log into a device running an affected release with a hardcoded username and password, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with manufacturer privilege level. An attacker could exploit this vulnerability by using this account to remotely log into an affected device. A successful exploit could allow the attacker to log into the device with manufacturer level access. This vulnerability affects SV9100 PBXes that are running software release 6.0 or higher. This vulnerability does not affect SV9100 software releases prior to 6.0.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
Encrypted database credentials in LaborOfficeFree affecting version 19.10. This vulnerability allows an attacker to read and extract the username and password from the database of 'LOF_service.exe' and 'LaborOfficeFree.exe' located in the '%programfiles(x86)%\LaborOfficeFree\' directory. This user can log in remotely and has root-like privileges.
An issue was discovered in TitanHQ WebTitan before 5.18. It has a hidden support account (with a hard-coded password) in the web administration interface, with administrator privileges. Anybody can log in with this account.
QNAP F_VioCard 2312 and F_VioGate 2308 have hardcoded entries in authorized_keys files. NOTE: 1. All active models are not affected. The last affected model was EOL since 2010. 2. The legacy authorization mechanism is no longer adopted in all active models
man-group/dtale version 3.10.0 is vulnerable to an authentication bypass and remote code execution (RCE) due to improper input validation. The vulnerability arises from a hardcoded `SECRET_KEY` in the flask configuration, allowing attackers to forge a session cookie if authentication is enabled. Additionally, the application fails to properly restrict custom filter queries, enabling attackers to execute arbitrary code on the server by bypassing the restriction on the `/update-settings` endpoint, even when `enable_custom_filters` is not enabled. This vulnerability allows attackers to bypass authentication mechanisms and execute remote code on the server.
Xerox ColorCube and WorkCenter devices in 2013 had hardcoded FTP and shell user accounts.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
A vulnerability in the Cisco Common Services Platform Collector (CSPC) could allow an unauthenticated, remote attacker to access an affected device by using an account that has a default, static password. This account does not have administrator privileges. The vulnerability exists because the affected software has a user account with a default, static password. An attacker could exploit this vulnerability by remotely connecting to the affected system using this account. A successful exploit could allow the attacker to log in to the CSPC using the default account. For Cisco CSPC 2.7.x, Cisco fixed this vulnerability in Release 2.7.4.6. For Cisco CSPC 2.8.x, Cisco fixed this vulnerability in Release 2.8.1.2.
The Atlassian Questions For Confluence app for Confluence Server and Data Center creates a Confluence user account in the confluence-users group with the username disabledsystemuser and a hardcoded password. A remote, unauthenticated attacker with knowledge of the hardcoded password could exploit this to log into Confluence and access all content accessible to users in the confluence-users group. This user account is created when installing versions 2.7.34, 2.7.35, and 3.0.2 of the app.
A hard-coded password vulnerability in the Fortinet FortiSIEM database component version 5.2.5 and below may allow attackers to access the device database via the use of static credentials.
Use of default credentials for the TELNET server in Petwant PF-103 firmware 4.3.2.50 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.
MCMS v5.2.4 was discovered to have a hardcoded shiro-key, allowing attackers to exploit the key and execute arbitrary code.
IBM Security Verify Governance 10.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 225222.
Use of a hard-coded cryptographic key in Pancake versions < 4.13.29 allows an attacker to forge session cookies, which may lead to remote privilege escalation.