Radiometrics VizAir is vulnerable to any remote attacker via access to the admin panel of the VizAir system without authentication. Once inside, the attacker can modify critical weather parameters such as wind shear alerts, inversion depth, and CAPE values, which are essential for accurate weather forecasting and flight safety. This unauthorized access could result in the disabling of vital alerts, causing hazardous conditions for aircraft, and manipulating runway assignments, which could result in mid-air conflicts or runway incursions.
Radiometrics VizAir is vulnerable to a lack of authentication mechanisms for critical functions, such as admin access and API requests. Attackers can modify configurations without authentication, potentially manipulating active runway settings and misleading air traffic control (ATC) and pilots. Additionally, manipulated meteorological data could mislead forecasters and ATC, causing inaccurate flight planning.
Realtek xPON RTL9601D SDK 1.9 stores passwords in plaintext which may allow attackers to possibly gain access to the device with root permissions via the build-in network monitoring tool and execute arbitrary commands.
Password Vulnerability in Safety production process management system v1.0 allows a remote attacker to escalate privileges, execute arbitrary code and obtain sensitive information via the password and account number parameters.
An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks.
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
On Supermicro H11, H12, M11, X9, X10, and X11 products, a combination of encryption and authentication problems in the virtual media service allows capture of BMC credentials and data transferred over virtual media devices. Attackers can use captured credentials to connect virtual USB devices to the server managed by the BMC.
admin_news.php in Archilles Newsworld up to 1.3.0 allows attackers to bypass authentication by obtaining the password hash for another user, for example through another Newsworld vulnerability, and specifying the hash in the pwd argument.
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An unauthenticated user can obtain the exposed password credentials to gain access to the following services: DDNS service, Mobile Network Provider, and OpenVPN service.
The HTTP client in Gradle before 5.6 sends authentication credentials originally destined for the configured host. If that host returns a 30x redirect, Gradle also sends those credentials to all subsequent hosts that the request redirects to. This is similar to CVE-2018-1000007.
The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.
The Voo branded NETGEAR CG3700b custom firmware V2.02.03 uses HTTP Basic Authentication over cleartext HTTP.
Insufficiently Protected Credentials vulnerability in LiteSpeed Technologies LiteSpeed Cache allows Authentication Bypass.This issue affects LiteSpeed Cache: from n/a before 6.5.0.1.
In Gradle Enterprise before 2018.5.3, Build Cache Nodes did not store the credentials at rest in an encrypted format.
HCL MyXalytics is affected by broken authentication. It allows attackers to compromise keys, passwords, and session tokens, potentially leading to identity theft and system control. This vulnerability arises from poor configuration, logic errors, or software bugs and can affect any application with access control, including databases, network infrastructure, and web applications.
In processMessageImpl of ClientModeImpl.java, there is a possible credential disclosure in the TOFU flow due to a logic error in the code. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
This vulnerability exists in GajShield Data Security Firewall firmware versions prior to v4.28 (except v4.21) due to insecure default credentials which allows remote attacker to login as superuser by using default username/password via web-based management interface and/or exposed SSH port thereby enabling remote attackers to execute arbitrary commands with administrative/superuser privileges on the targeted systems. The vulnerability has been addressed by forcing the user to change their default password to a new non-default password.
**UNSUPPORTED WHEN ASSIGNED** Insecure default credentials for the Telnet function in the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an attacker to log in to the management interface if the administrators have the option to change the default credentials but fail to do so.
The User Verification WordPress plugin before 1.0.94 was affected by an Auth Bypass security vulnerability. To bypass authentication, we only need to know the user’s username. Depending on whose username we know, which can be easily queried because it is usually public data, we may even be given an administrative role on the website.
An access control issue in Revenue Collection System v1.0 allows unauthenticated attackers to view the contents of /admin/DBbackup/ directory.
Aztech WMB250AC Mesh Routers Firmware Version 016 2020 is vulnerable to PHP Type Juggling in file /var/www/login.php, allows attackers to gain escalated privileges only when specific conditions regarding a given accounts hashed password.
RustFS is a distributed object storage system built in Rust. In versions 1.0.0-alpha.13 through 1.0.0-alpha.78, a flawed `deny_only` short-circuit in RustFS IAM allows a restricted service account or STS credential to self-issue an unrestricted service account, inheriting the parent’s full privileges. This enables privilege escalation and bypass of session/inline policy restrictions. Version 1.0.0-alpha.79 fixes the issue.
A plaintext storage of a password vulnerability [CWE-256] in FortiSIEM 6.7 all versions, 6.6 all versions, 6.5 all versions, 6.4 all versions, 6.3 all versions, 6.2 all versions, 6.1 all versions, 5.4 all versions, 5.3 all versions may allow an attacker able to access user DB content to impersonate any admin user on the device GUI.
Username Enumeration vulnerabilities allow access to application level username add, delete, modify and list functions. Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
CGI Script Center News Update 1.1 does not properly validate the original news administration password during a password change operation, which allows remote attackers to modify the password without knowing the original password.
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
SAP Business Objects Business Intelligence Platform (CMC), version 4.1, 4.2, shows cleartext password in the response, leading to Information Disclosure. It involves social engineering in order to gain access to system and If password is known, it would give administrative rights to the attacker to read/modify delete the data and rights within the system.
The WebTools component on Canon Oce ColorWave 3500 5.1.1.0 devices allows attackers to retrieve stored SMB credentials via the export feature, even though these are intentionally inaccessible in the UI.
rpc.py through 0.6.0 allows Remote Code Execution because an unpickle occurs when the "serializer: pickle" HTTP header is sent. In other words, although JSON (not Pickle) is the default data format, an unauthenticated client can cause the data to be processed with unpickle.
ARRIS SBG6580-2 D30GW-SEAEAGLE-1.5.2.5-GA-00-NOSH devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
D-Link DCM-604 DCM604_C1_ViaCabo_1.04_20130606 and DCM-704 EU_DCM-704_1.10 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.32 and iso.3.6.1.4.1.4413.2.2.2.1.5.4.2.4.1.2.32 SNMP requests.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Marval MSM v14.19.0.12476 has a 0-Click Account Takeover vulnerability which allows an attacker to change any user's password in the organization, this means that the user can also escalate achieve Privilege Escalation by changing the administrator password.
Insufficiently protected credentials for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable information disclosure and escalation of privilege via network access.
Grand MA 300 allows a brute-force attack on the PIN.
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
D-Link DIR-100 4.03B07 has PPTP and poe information disclosure
E3 Site Supervisor (firmware version < 2.31F01) has a default admin user "ONEDAY" with a daily generated password. An attacker can predictably generate the password for ONEDAY. The oneday user cannot be deleted or modified by any user.
A security regression of CVE-2019-9636 was discovered in python since commit d537ab0ff9767ef024f26246899728f0116b1ec3 affecting versions 2.7, 3.5, 3.6, 3.7 and from v3.8.0a4 through v3.8.0b1, which still allows an attacker to exploit CVE-2019-9636 by abusing the user and password parts of a URL. When an application parses user-supplied URLs to store cookies, authentication credentials, or other kind of information, it is possible for an attacker to provide specially crafted URLs to make the application locate host-related information (e.g. cookies, authentication data) and send them to a different host than where it should, unlike if the URLs had been correctly parsed. The result of an attack may vary based on the application.
An issue was discovered in Nitrokey FIDO U2F firmware through 1.1. Communication between the microcontroller and the secure element transmits credentials in plain. This allows an adversary to eavesdrop the communication and derive the secrets stored in the microcontroller. As a result, the attacker is able to arbitrarily manipulate the firmware of the microcontroller.
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
An issue was discovered in the 3CX Phone System Management Console prior to version 18 Update 3 FINAL. An unauthenticated attacker could abuse improperly secured access to arbitrary files on the server (via /Electron/download directory traversal in conjunction with a path component that uses backslash characters), leading to cleartext credential disclosure. Afterwards, the authenticated attacker is able to upload a file that overwrites a 3CX service binary, leading to Remote Code Execution as NT AUTHORITY\SYSTEM on Windows installations. NOTE: this issue exists because of an incomplete fix for CVE-2022-48482.
An issue discovered in Relyum RELY-PCIe 22.2.1 and RELY-REC 23.1.0 allows for unauthorized password changes due to no check for current password.
ONTAP Select Deploy administration utility versions 2.2 through 2.12.1 transmit credentials in plaintext.
Unprotected Storage of Credentials vulnerability in McAfee Advanced Threat Defense (ATD) prior to 4.8 allows local attacker to gain access to the root password via accessing sensitive files on the system. This was originally published with a CVSS rating of High, further investigation has resulted in this being updated to Critical. The root password is common across all instances of ATD prior to 4.8. See the Security bulletin for further details
Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network.
NET&SYS MNG2120J 5.76.1006c and MNG6300 5.83.6305jrc2 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.