CVE-2023-3379
Assigner-CERT@VDE
ShareView Details
Assigner-CERT@VDE
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 5.37%
||
7 Day CHG~0.00%
Published-20 Nov, 2023 | 07:23
Updated-02 Oct, 2024 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAGO: Improper Privilege Management in web-based management

Wago web-based management of multiple products has a vulnerability which allows an local authenticated attacker to change the passwords of other non-admin users and thus to escalate non-root privileges.

Action-Not Available
Vendor-wagoWAGOWago
Product-compact_controller_100_firmwarepfc200_firmwaretouch_panel_600_advanced_firmwaretouch_panel_600_marine_firmwaretouch_panel_600_standardtouch_panel_600_advancedcompact_controller_100edge_controllertouch_panel_600_standard_firmwarepfc200edge_controller_firmwarepfc100_firmwarepfc100touch_panel_600_marineTouch Panel 600 Advanced Line (762-5xxx)PFC100 (750-810x/xxx-xxx)Touch Panel 600 Standard Line (762-4xxx)PFC200 (750-821x/xxx-xxx)Compact Controller 100 (751-9301)Edge Controller (752-8303/8000-002)Touch Panel 600 Marine Line (762-6xxx)PFC200 (750-820x/xxx-xxx)
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-1620
Assigner-CERT@VDE
ShareView Details
Assigner-CERT@VDE
CVSS Score-4.9||MEDIUM
EPSS-0.13% / 32.65%
||
7 Day CHG~0.00%
Published-26 Jun, 2023 | 06:19
Updated-12 Nov, 2024 | 14:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAGO: DoS in multiple products in multiple versions using Codesys

Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a specifically crafted packet to the CODESYS V2 runtime.

Action-Not Available
Vendor-wagoWago
Product-750-8202\/040-001_firmware750-8203_firmware750-8212\/025-002750-890\/025-000750-8213\/040-010_firmware750-8210_firmware750-8206_firmware750-8215_firmware750-8211\/040-000750-891750-890\/040-000750-831\/000-002750-831750-891_firmware750-8213\/040-010750-8208\/025-001_firmware750-8207\/025-001750-880750-8215750-8202\/000-012750-8212\/040-001_firmware750-8202\/000-022750-8216\/040-000_firmware750-8212\/040-000_firmware750-889750-8212\/000-100_firmware750-331_firmware750-8217_firmware750-8212\/025-000_firmware750-8211\/040-001750-8213750-8214_firmware750-829_firmware750-890\/025-002750-880\/040-000_firmware750-885\/025-000750-8202\/040-000750-832\/000-002750-8204750-8213_firmware750-8207_firmware750-8206\/025-001_firmware750-8204\/025-000_firmware750-890\/025-001_firmware750-832\/000-002_firmware750-8206\/040-000750-880\/025-000750-8204_firmware750-8217\/625-000_firmware750-8202\/000-012_firmware750-8212750-893_firmware750-880\/040-000750-8202\/025-001_firmware750-881750-882_firmware750-8216\/025-001_firmware750-8202_firmware750-862750-8207750-8217\/025-000_firmware750-832_firmware750-8206750-8208_firmware750-8207\/025-000_firmware750-885\/025-000_firmware750-8207\/025-000750-8211\/040-001_firmware750-885750-8216\/025-000_firmware750-8216750-890\/040-000_firmware750-8212\/000-100750-8216\/025-001750-8210\/040-000_firmware750-8210\/025-000750-880_firmware750-8206\/040-001750-8207\/025-001_firmware750-8216_firmware750-8202\/040-001750-8206\/025-000750-8212\/025-002_firmware750-880\/025-001_firmware750-8212_firmware750-8202\/025-000_firmware750-8208750-8211\/040-000_firmware750-881_firmware750-8217\/025-000750-8212\/025-001_firmware750-890\/025-002_firmware750-885_firmware750-890\/025-000_firmware750-8212\/040-010_firmware750-8202\/000-011_firmware750-8208\/025-000_firmware750-880\/025-002_firmware750-893750-8212\/040-001750-8211_firmware750-8206\/040-001_firmware750-8208\/025-001750-852_firmware750-8208\/025-000750-8212\/040-010750-8212\/040-000750-890_firmware750-880\/025-001750-8217\/625-000750-8203750-890\/025-001750-823750-8214750-8202750-8210\/040-000750-8217\/600-000_firmware750-8203\/025-000_firmware750-8203\/025-000750-823_firmware750-8202\/025-002750-8210\/025-000_firmware750-8206\/040-000_firmware750-889_firmware750-890750-832750-8211750-862_firmware750-8202\/025-002_firmware750-880\/025-000_firmware750-880\/025-002750-8204\/025-000750-8212\/025-000750-331750-8202\/025-000750-8206\/025-000_firmware750-829750-8212\/025-001750-8202\/000-022_firmware750-8216\/040-000750-831_firmware750-8202\/000-011750-8217\/600-000750-8206\/025-001750-8202\/025-001750-8216\/025-000750-8202\/040-000_firmware750-882750-831\/000-002_firmware750-852750-8217750-8210750-332750-890/xxx-xxx750-831/xxx-xxx750-880/xxx-xxx750-331750-8203/xxx-xxx750-885/xxx-xxx750-8207/xxx-xxx750-8206/xxx-xxx750-829750-823750-8211/xxx-xxx750-8204/xxx-xxx750-893750-881750-8217/xxx-xxx750-8216/xxx-xxx750-8213/xxx-xxx750-8210/xxx-xxx750-882750-832/xxx-xxx750-891750-862750-889750-8212/xxx-xxx750-852750-8202/xxx-xxx750-8214/xxx-xxx750-8208/xxx-xxx
CWE ID-CWE-1288
Improper Validation of Consistency within Input
CVE-2023-1619
Assigner-CERT@VDE
ShareView Details
Assigner-CERT@VDE
CVSS Score-4.9||MEDIUM
EPSS-0.17% / 39.02%
||
7 Day CHG~0.00%
Published-26 Jun, 2023 | 06:18
Updated-02 Oct, 2024 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAGO: DoS in multiple versions of multiple products

Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a malformed packet.

Action-Not Available
Vendor-wagoWago
Product-750-8202\/040-001_firmware750-8203_firmware750-8212\/025-002750-890\/025-000750-8213\/040-010_firmware750-8210_firmware750-8206_firmware750-8215_firmware750-8211\/040-000750-891750-890\/040-000750-831\/000-002750-831750-891_firmware750-8213\/040-010750-8208\/025-001_firmware750-8207\/025-001750-880750-8215750-8202\/000-012750-8212\/040-001_firmware750-8202\/000-022750-8216\/040-000_firmware750-8212\/040-000_firmware750-889750-8212\/000-100_firmware750-331_firmware750-8217_firmware750-8212\/025-000_firmware750-8211\/040-001750-8213750-8214_firmware750-829_firmware750-890\/025-002750-880\/040-000_firmware750-885\/025-000750-8202\/040-000750-832\/000-002750-8204750-8213_firmware750-8207_firmware750-8206\/025-001_firmware750-8204\/025-000_firmware750-890\/025-001_firmware750-832\/000-002_firmware750-8206\/040-000750-880\/025-000750-8204_firmware750-8217\/625-000_firmware750-8202\/000-012_firmware750-8212750-893_firmware750-880\/040-000750-8202\/025-001_firmware750-881750-882_firmware750-8216\/025-001_firmware750-8202_firmware750-862750-8207750-8217\/025-000_firmware750-832_firmware750-8206750-8208_firmware750-8207\/025-000_firmware750-885\/025-000_firmware750-8207\/025-000750-8211\/040-001_firmware750-885750-8216\/025-000_firmware750-8216750-890\/040-000_firmware750-8212\/000-100750-8216\/025-001750-8210\/040-000_firmware750-8210\/025-000750-880_firmware750-8206\/040-001750-8207\/025-001_firmware750-8216_firmware750-8202\/040-001750-8206\/025-000750-8212\/025-002_firmware750-880\/025-001_firmware750-8212_firmware750-8202\/025-000_firmware750-8208750-8211\/040-000_firmware750-881_firmware750-8217\/025-000750-8212\/025-001_firmware750-890\/025-002_firmware750-885_firmware750-890\/025-000_firmware750-8212\/040-010_firmware750-8202\/000-011_firmware750-8208\/025-000_firmware750-880\/025-002_firmware750-893750-8212\/040-001750-8211_firmware750-8206\/040-001_firmware750-8208\/025-001750-852_firmware750-8208\/025-000750-8212\/040-010750-8212\/040-000750-890_firmware750-880\/025-001750-8217\/625-000750-8203750-890\/025-001750-823750-8214750-8202750-8210\/040-000750-8217\/600-000_firmware750-8203\/025-000_firmware750-8203\/025-000750-823_firmware750-8202\/025-002750-8210\/025-000_firmware750-8206\/040-000_firmware750-889_firmware750-890750-832750-8211750-862_firmware750-8202\/025-002_firmware750-880\/025-000_firmware750-880\/025-002750-8204\/025-000750-8212\/025-000750-331750-8202\/025-000750-8206\/025-000_firmware750-829750-8212\/025-001750-8202\/000-022_firmware750-8216\/040-000750-831_firmware750-8202\/000-011750-8217\/600-000750-8206\/025-001750-8202\/025-001750-8216\/025-000750-8202\/040-000_firmware750-882750-831\/000-002_firmware750-852750-8217750-8210750-332750-890/xxx-xxx750-831/xxx-xxx750-880/xxx-xxx750-331750-8203/xxx-xxx750-885/xxx-xxx750-8207/xxx-xxx750-8206/xxx-xxx750-829750-823750-8211/xxx-xxx750-8204/xxx-xxx750-893750-881750-8217/xxx-xxx750-8216/xxx-xxx750-8213/xxx-xxx750-8210/xxx-xxx750-882750-832/xxx-xxx750-891750-862750-889750-8212/xxx-xxx750-852750-8202/xxx-xxx750-8214/xxx-xxx750-8208/xxx-xxx
CWE ID-CWE-1288
Improper Validation of Consistency within Input
CVE-2019-5181
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.07% / 20.80%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:31
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can cause a stack buffer overflow, resulting in code execution. An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is overflowed with the call to sprintf() for any subnetmask values that are greater than 1024-len(‘/etc/config-tools/config_interfaces interface=X1 state=enabled subnet-mask=‘) in length. A subnetmask value of length 0x3d9 will cause the service to crash.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5180
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.07% / 20.61%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:30
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is overflowed with the call to sprintf() for any ip values that are greater than 1024-len(‘/etc/config-tools/config_interfaces interface=X1 state=enabled ip-address=‘) in length. A ip value of length 0x3da will cause the service to crash.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5179
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.07% / 20.61%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:30
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5178
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.07% / 20.61%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:25
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is overflowed with the call to sprintf() for any hostname values that are greater than 1024-len(‘/etc/config-tools/change_hostname hostname=‘) in length. A hostname value of length 0x3fd will cause the service to crash.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5177
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-5.5||MEDIUM
EPSS-0.17% / 38.84%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:25
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). The destination buffer sp+0x440 is overflowed with the call to sprintf() for any domainname values that are greater than 1024-len(‘/etc/config-tools/edit_dns_server domain-name=‘) in length. A domainname value of length 0x3fa will cause the service to crash.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5176
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-5.5||MEDIUM
EPSS-0.07% / 20.61%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:24
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file.The destination buffer sp+0x40 is overflowed with the call to sprintf() for any gateway values that are greater than 512-len(‘/etc/config-tools/config_default_gateway number=0 state=enabled value=‘) in length. A gateway value of length 0x7e2 will cause the service to crash.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5171
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.23% / 45.49%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:17
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send specially crafted packet at 0x1ea48 to the extracted hostname value from the xml file that is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled ip-address=<contents of ip node> using sprintf().

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5170
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.35% / 56.73%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:17
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1e87c the extracted hostname value from the xml file is used as an argument to /etc/config-tools/change_hostname hostname=<contents of hostname node> using sprintf(). This command is later executed via a call to system().

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5169
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.31% / 53.91%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 23:17
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e900 the extracted gateway value from the xml file is used as an argument to /etc/config-tools/config_default_gateway number=0 state=enabled value=<contents of gateway node> using sprintf(). This command is later executed via a call to system().

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5174
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.35% / 56.73%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 22:25
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1e9fc the extracted subnetmask value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled subnet-mask=<contents of subnetmask node> using sprintf(). This command is later executed via a call to system().

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5175
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.35% / 56.73%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 22:25
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1ea28 the extracted type value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled config-type=<contents of type node> using sprintf(). This command is later executed via a call to system().

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5172
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.27% / 50.08%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 22:18
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e840 the extracted ntp value from the xml file is used as an argument to /etc/config-tools/config_sntp time-server-%d=<contents of ntp node> using sprintf(). This command is later executed via a call to system(). This is done in a loop and there is no limit to how many ntp entries will be parsed from the xml file.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5173
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.35% / 56.73%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 22:18
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e9fc the extracted state value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=<contents of state node> using sprintf(). This command is later executed via a call to system().

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5182
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-5.5||MEDIUM
EPSS-0.07% / 20.61%
||
7 Day CHG~0.00%
Published-11 Mar, 2020 | 22:09
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file.The destination buffer sp+0x440 is overflowed with the call to sprintf() for any type values that are greater than 1024-len(‘/etc/config-tools/config_interfaces interface=X1 state=enabled config-type=‘) in length. A type value of length 0x3d9 will cause the service to crash.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5106
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-5.5||MEDIUM
EPSS-0.06% / 19.80%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 23:41
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A hard-coded encryption key vulnerability exists in the authentication functionality of WAGO e!Cockpit version 1.5.1.1. An attacker with access to communications between e!Cockpit and CoDeSyS Gateway can trivially recover the password of any user attempting to log in, in plain text.

Action-Not Available
Vendor-wagoWago
Product-e\!cockpitWAGO e!Cockpit
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-5107
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.5||HIGH
EPSS-0.18% / 40.24%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 23:41
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A cleartext transmission vulnerability exists in the network communication functionality of WAGO e!Cockpit version 1.5.1.1. An attacker with access to network traffic can easily intercept, interpret, and manipulate data coming from, or destined for e!Cockpit. This includes passwords, configurations, and binaries being transferred to endpoints.

Action-Not Available
Vendor-wagoWago
Product-e\!cockpitWAGO e!Cockpit
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2019-5134
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.5||HIGH
EPSS-0.28% / 51.33%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 23:41
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable regular expression without anchors vulnerability exists in the Web-Based Management (WBM) authentication functionality of WAGO PFC200 versions 03.00.39(12) and 03.01.07(13), and WAGO PFC100 version 03.00.39(12). A specially crafted authentication request can bypass regular expression filters, resulting in sensitive information disclosure.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc100pfc200_firmwarepfc100_firmwareWAGO PFC100 FirmwareWAGO PFC200 Firmware
CVE-2019-5161
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-4.93% / 89.21%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 23:32
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable remote code execution vulnerability exists in the Cloud Connectivity functionality of WAGO PFC200 versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). A specially crafted XML file will direct the Cloud Connectivity service to download and execute a shell script with root privileges.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2019-5156
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-2.85% / 85.72%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 23:14
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the cloud connectivity functionality of WAGO PFC200 versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). An attacker can inject operating system commands into the TimeoutPrepared parameter value contained in the firmware update command.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5157
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-2.85% / 85.72%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 23:14
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the Cloud Connectivity functionality of WAGO PFC200 Firmware versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). An attacker can inject OS commands into the TimeoutUnconfirmed parameter value contained in the Firmware Update command.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5158
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.26% / 48.83%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 23:14
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable firmware downgrade vulnerability exists in the firmware update package functionality of the WAGO e!COCKPIT automation software v1.6.1.5. A specially crafted firmware update file can allow an attacker to install an older firmware version while the user thinks a newer firmware version is being installed. An attacker can create a custom firmware update package with invalid metadata in order to trigger this vulnerability.

Action-Not Available
Vendor-wagoWago
Product-e\!cockpitWAGO e!COCKPIT
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-5159
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.34% / 55.70%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 22:35
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable improper input validation vulnerability exists in the firmware update functionality of WAGO e!COCKPIT automation software v1.6.0.7. A specially crafted firmware update file can allow an attacker to write arbitrary files to arbitrary locations on WAGO controllers as a part of executing a firmware update, potentially resulting in code execution. An attacker can create a malicious firmware update package file using any zip utility. The user must initiate a firmware update through e!COCKPIT and choose the malicious wup file using the file browser to trigger the vulnerability.

Action-Not Available
Vendor-wagoWago
Product-e\!cockpitWAGO e!COCKPIT
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2019-5160
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-2.17% / 83.62%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 22:35
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable improper host validation vulnerability exists in the Cloud Connectivity functionality of WAGO PFC200 Firmware versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). A specially crafted HTTPS POST request can cause the software to connect to an unauthorized host, resulting in unauthorized access to firmware update functionality. An attacker can send an authenticated HTTPS POST request to direct the Cloud Connectivity software to connect to an attacker controlled Azure IoT Hub node.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CVE-2019-5168
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.47% / 63.58%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 22:25
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). An attacker can send a specially crafted XML cache file At 0x1e8a8 the extracted domainname value from the xml file is used as an argument to /etc/config-tools/edit_dns_server domain-name=<contents of domainname node> using sprintf().This command is later executed via a call to system().

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5167
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.58% / 67.87%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 22:25
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). At 0x1e3f0 the extracted dns value from the xml file is used as an argument to /etc/config-tools/edit_dns_server %s dns-server-nr=%d dns-server-name=<contents of dns node> using sprintf(). This command is later executed via a call to system(). This is done in a loop and there is no limit to how many dns entries will be parsed from the xml file.

Action-Not Available
Vendor-wagoWago
Product-pfc_200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5166
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.05% / 16.45%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 22:25
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable stack buffer overflow vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can cause a stack buffer overflow, resulting in code execution. An attacker can send a specially crafted packet to trigger the parsing of this cache file.

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5135
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-5.3||MEDIUM
EPSS-0.16% / 37.95%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 21:59
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable timing discrepancy vulnerability exists in the authentication functionality of the Web-Based Management (WBM) web application on WAGO PFC100/200 controllers. The WBM application makes use of the PHP crypt() function which can be exploited to disclose hashed user credentials. This affects WAGO PFC200 Firmware version 03.00.39(12) and version 03.01.07(13), and WAGO PFC100 Firmware version 03.00.39(12).

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc100pfc200_firmwarepfc100_firmwareWAGO PFC100 FirmwareWAGO PFC200 Firmware
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CVE-2019-5149
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.10%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 21:59
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The WBM web application on firmwares prior to 03.02.02 and 03.01.07 on the WAGO PFC100 and PFC2000, respectively, runs on a lighttpd web server and makes use of the FastCGI module, which is intended to provide high performance for all Internet applications without the penalties of Web server APIs. However, the default configuration of this module appears to limit the number of concurrent php-cgi processes to two, which can be abused to cause a denial of service of the entire web server. This affects WAGO PFC200 Firmware version 03.00.39(12) and version 03.01.07(13), and WAGO PFC100 Firmware version 03.00.39(12) and version 03.02.02(14).

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc100pfc200_firmwarepfc100_firmwareWAGO PFC100 FirmwareWAGO PFC200 Firmware
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2019-5155
Assigner-Talos
ShareView Details
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-2.46% / 84.62%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 21:59
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the cloud connectivity feature of WAGO PFC200. An attacker can inject operating system commands into any of the parameter values contained in the firmware update command. This affects WAGO PFC200 Firmware version 03.02.02(14), version 03.01.07(13), and version 03.00.39(12)

Action-Not Available
Vendor-wagoWago
Product-pfc200pfc200_firmwareWAGO PFC200 Firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')