A vulnerability, which was classified as critical, was found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. Affected is the function genCode of the file novel-admin/src/main/java/com/java2nb/common/controller/GeneratorController.java. The manipulation leads to missing authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
In SapphireIMS 5.0, it is possible to create local administrator on any client without requiring any credentials by directly accessing RemoteMgmtTaskSave (Automation Tasks) feature and not having a JSESSIONID.
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
A vulnerability in the Policy Builder interface of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to access the Policy Builder interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by accessing the Policy Builder interface. A successful exploit could allow the attacker to make changes to existing repositories and create new repositories. Cisco Bug IDs: CSCvi35109.
In SapphireIMS 5.0, it is possible to take over an account by sending a request to the Save_Password form as shown in POC. Notice that we do not require a JSESSIONID in this request and can reset any user’s password by changing the username to that user and password to base64(desired password).
A vulnerability in the Redis implementation used by the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software could allow an unauthenticated, remote attacker to modify key-value pairs for short-lived events stored by the Redis server. The vulnerability is due to improper authentication when accessing the Redis server. An unauthenticated attacker could exploit this vulnerability by modifying key-value pairs stored within the Redis server database. An exploit could allow the attacker to reduce the efficiency of the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software.
A vulnerability in the Open Systems Gateway initiative (OSGi) interface of Cisco Policy Suite before 18.1.0 could allow an unauthenticated, remote attacker to directly connect to the OSGi interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by directly connecting to the OSGi interface. An exploit could allow the attacker to access or change any files that are accessible by the OSGi process. Cisco Bug IDs: CSCvh18017.
newbee-mall all versions are affected by incorrect access control to remotely gain privileges through AdminLoginInterceptor.java. The authentication logic of the system's background /admin is in code AdminLoginInterceptor, which can be bypassed.
An issue was discovered in the box application on HiSilicon based IPTV/H.264/H.265 video encoders. The file-upload endpoint does not enforce authentication. Attackers can send an unauthenticated HTTP request to upload a custom firmware component, possibly in conjunction with command injection, to achieve arbitrary code execution.
SICK Package Analytics software up to and including version V04.0.0 are vulnerable to an authentication bypass by directly interfacing with the REST API. An attacker can send unauthorized requests, bypass current authentication controls presented by the application and could potentially write files without authentication.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
D-Link DWL-900AP+ Access Point 2.1 and 2.2 allows remote attackers to access the TFTP server without authentication and read the config.img file, which contains sensitive information such as the administrative password, the WEP encryption keys, and network configuration information.
Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.
In Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100, ports 30001/TCP to 30003/TCP listen for arbitrary URScript code and execute the code. This enables a remote attacker who has access to the ports to remotely execute code that may allow root access to be obtained.
The previous default setting for Airflow's Experimental API was to allow all API requests without authentication, but this poses security risks to users who miss this fact. From Airflow 1.10.11 the default has been changed to deny all requests by default and is documented at https://airflow.apache.org/docs/1.10.11/security.html#api-authentication. Note this change fixes it for new installs but existing users need to change their config to default `[api]auth_backend = airflow.api.auth.backend.deny_all` as mentioned in the Updating Guide: https://github.com/apache/airflow/blob/1.10.11/UPDATING.md#experimental-api-will-deny-all-request-by-default
A vulnerability in the Policy Builder database of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to connect directly to the Policy Builder database. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by connecting directly to the Policy Builder database. A successful exploit could allow the attacker to access and change any data in the Policy Builder database. Cisco Bug IDs: CSCvh06134.
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
BMC Track-It! 11.3.0.355 does not require authentication on TCP port 9010, which allows remote attackers to upload arbitrary files, execute arbitrary code, or obtain sensitive credential and configuration information via a .NET Remoting request to (1) FileStorageService or (2) ConfigurationService.
BSS Continuity CMS 4.2.22640.0 has an Authentication Bypass vulnerability
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request.
The UI in DevSpace 4.13.0 allows web sites to execute actions on pods (on behalf of a victim) because of a lack of authentication for the WebSocket protocol. This leads to remote code execution.
xlockmore 5.13 and 5.22 segfaults when using libpam-opensc and returns the underlying xsession. This allows unauthorized users access to the X session.
HCL OneTest UI V9.5, V10.0, and V10.1 does not perform authentication for functionality that either requires a provable user identity or consumes a significant amount of resources.
Authentication Bypass vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to change or update any configuration settings, or gain administrator functionality via a crafted HTTP request parameter.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
An issue was discovered in CIPPlanner CIPAce 9.1 Build 2019092801. Upload.ashx allows remote attackers to execute arbitrary code by uploading and executing an ASHX file.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
An issue was discovered in the Responsive Poll through 1.3.4 for Wordpress. It allows an unauthenticated user to manipulate polls, e.g., delete, clone, or view a hidden poll. This is due to the usage of the callback wp_ajax_nopriv function in Includes/Total-Soft-Poll-Ajax.php for sensitive operations.
The SolarWinds Orion API is vulnerable to an authentication bypass that could allow a remote attacker to execute API commands. This vulnerability could allow a remote attacker to bypass authentication and execute API commands which may result in a compromise of the SolarWinds instance. SolarWinds Orion Platform versions 2019.4 HF 5, 2020.2 with no hotfix installed, and 2020.2 HF 1 are affected.
Control Web Panel Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Control Web Panel. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of authentication within the web interface. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of a valid CWP user. Was ZDI-CAN-20582.
Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission.
eQ-3 Homematic CCU2 prior to 2.47.10 and CCU3 prior to 3.47.10 JSON API has Improper Access Control for Interface.***Metadata related operations, resulting in the ability to read, set and deletion of Metadata.
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation.
On Netis WF2411 with firmware 2.1.36123 and other Netis WF2xxx devices (possibly WF2411 through WF2880), there is a stack-based buffer overflow that does not require authentication. This can cause denial of service (device restart) or remote code execution. This vulnerability can be triggered by a GET request with a long HTTP "Authorization: Basic" header that is mishandled by user_auth->user_ok in /bin/boa.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186).
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
wan.htm page on Zyxel NBG-418N v2 with firmware version V1.00(AARP.9)C0 can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify data fields of the page.
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. A remote attacker with network access to the Video Server could exploit this vulnerability to read the SiVMS/SiNVR users database, including the passwords of all users in obfuscated cleartext.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.
xlockmore 5.13 allows potential xlock bypass when FVWM switches to the same virtual desktop as a new Gaim window.
The Web portal of the WiFi module of VPNCrypt M10 2.6.5 allows unauthenticated users to send HTTP POST request to several critical Administrative functions such as, changing credentials of the Administrator account or connect the product to a rogue access point.