Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can gain remote code execution by sending specifically crafted objects to one of its functions. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
FTP servers can allow an attacker to connect to arbitrary ports on machines other than the FTP client, aka FTP bounce.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.
A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
The Quagga BGP daemon (bgpd) prior to version 1.2.3 can double-free memory when processing certain forms of UPDATE message, containing cluster-list and/or unknown attributes. A successful attack could cause a denial of service or potentially allow an attacker to execute arbitrary code.
The rate limiting feature in NTP 4.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to have unspecified impact via a large number of crafted requests.
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions < IP8), Cerberus PRO EN Fire Panel FC72x IP6 (All versions < IP6 SR3), Cerberus PRO EN Fire Panel FC72x IP7 (All versions < IP7 SR5), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions < V3.0.6602), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.0.5016), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions < V3.2.6601), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.2.5015), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions < MP8), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions < MP6 SR3), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions < MP7 SR5), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions < V3.0.6602), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.0.5016), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions < V3.2.6601), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.2.5015), Sinteso Mobile (All versions < V3.0.0). The network communication library in affected systems does not validate the length of certain X.509 certificate attributes which might result in a stack-based buffer overflow. This could allow an unauthenticated remote attacker to execute code on the underlying operating system with root privileges.
An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability.
Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution.
LibVNC through 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.
LibVNC before 0.9.12 contains multiple heap out-of-bounds write vulnerabilities in libvncclient/rfbproto.c. The fix for CVE-2018-20019 was incomplete.
A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access.
LibVNC before 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.
A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known.
LibVNC before commit a83439b9fbe0f03c48eb94ed05729cb016f8b72f contains multiple heap out-of-bound write vulnerabilities in VNC client code that can result remote code execution
An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client.
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known
A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection.
A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code.
A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters required for the `exportDiagramPage` endpoint. This could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.
The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session.
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.
The package y18n before 3.2.2, 4.0.1 and 5.0.5, is vulnerable to Prototype Pollution.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system.
Buffer overflow in the RFC_START_PROGRAM function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control.
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793).
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions.
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not properly validate parameters of certain GET and POST requests. This could allow an unauthenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1), Mendix Forgot Password Appstore module (Mendix 7 compatible) (All versions < V3.2.2). Initial passwords are generated in an insecure manner. This could allow an unauthenticated remote attacker to efficiently brute force passwords in specific situations.
Siemens Speedstream Wireless Router 2624 allows local users to bypass authentication and access protected files by using the Universal Plug and Play UPnP/1.0 component.
xmlparse.c in Expat (aka libexpat) before 2.4.5 allows attackers to insert namespace-separator characters into namespace URIs.
In Expat (aka libexpat) before 2.4.5, there is an integer overflow in storeRawNames.
A vulnerability has been identified in COMOS V10.2 (All versions), COMOS V10.3.3.1 (All versions < V10.3.3.1.45), COMOS V10.3.3.2 (All versions < V10.3.3.2.33), COMOS V10.3.3.3 (All versions < V10.3.3.3.9), COMOS V10.3.3.4 (All versions < V10.3.3.4.6), COMOS V10.4.0.0 (All versions < V10.4.0.0.31), COMOS V10.4.1.0 (All versions < V10.4.1.0.32), COMOS V10.4.2.0 (All versions < V10.4.2.0.25). Cache validation service in COMOS is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.
It was discovered that websockets.c in LibVNCServer prior to 0.9.12 did not properly decode certain WebSocket frames. A malicious attacker could exploit this by sending specially crafted WebSocket frames to a server, causing a heap-based buffer overflow.