The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
Missing Authentication for Critical Function, Missing Authorization vulnerability in Menulux Information Technologies Managment Portal allows Collect Data as Provided by Users.This issue affects Managment Portal: through 21.05.2024.
Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.6.0 as soon as possible (available in SICK Support Portal).
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.
An issue was discovered in the LifterLMS plugin through 3.34.5 for WordPress. The upload_import function in the class.llms.admin.import.php script is prone to an unauthenticated options import vulnerability that could lead to privilege escalation (administrator account creation), website redirection, and stored XSS.
Flag Forge is a Capture The Flag (CTF) platform. Starting in version 2.0.0 and prior to version 2.3.2, the `/api/admin/badge-templates` (GET) and `/api/admin/badge-templates/create` (POST) endpoints previously allowed access without authentication or authorization. This could have enabled unauthorized users to retrieve all badge templates and sensitive metadata (createdBy, createdAt, updatedAt) and/or create arbitrary badge templates in the database. This could lead to data exposure, database pollution, or abuse of the badge system. The issue has been fixed in FlagForge v2.3.2. GET, POST, UPDATE, and DELETE endpoints now require authentication. Authorization checks ensure only admins can access and modify badge templates. No reliable workarounds are available.
Missing authentication for critical function in Visual Studio Code extension for Arduino allows an unauthenticated attacker to perform remote code execution through network attack vector.
Password recovery vulnerability in SICK SIM4000 (PPC) Partnumber 1078787 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.10.1 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM4000. A fix is planned but not yet scheduled.
FreeFloat FTP Server contains multiple critical design flaws that allow unauthenticated remote attackers to upload arbitrary files to sensitive system directories. The server accepts empty credentials, defaults user access to the root of the C:\ drive, and imposes no restrictions on file type or destination path. These conditions enable attackers to upload executable payloads and .mof files to locations such as system32 and wbem\mof, where Windows Management Instrumentation (WMI) automatically processes and executes them. This results in remote code execution with SYSTEM-level privileges, without requiring user interaction.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) allows unauthenticated device administration.
Intesync Solismed 3.3sp has Incorrect Access Control.
Improper Authentication vulnerability in upKeeper Solutions product upKeeper Manager allows Authentication Bypass.This issue affects upKeeper Manager: through 5.1.9.
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
The SolarWinds Orion API is vulnerable to an authentication bypass that could allow a remote attacker to execute API commands. This vulnerability could allow a remote attacker to bypass authentication and execute API commands which may result in a compromise of the SolarWinds instance. SolarWinds Orion Platform versions 2019.4 HF 5, 2020.2 with no hotfix installed, and 2020.2 HF 1 are affected.
A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.
Cybele Software Thinfinity Workspace before v7.0.2.113 was discovered to contain an access control issue in the API endpoint where Web Sockets connections are established.
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7001 of demo-sdc-sdc-wfd-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in Squid through 4.7. When handling requests from users, Squid checks its rules to see if the request should be denied. Squid by default comes with rules to block access to the Cache Manager, which serves detailed server information meant for the maintainer. This rule is implemented via url_regex. The handler for url_regex rules URL decodes an incoming request. This allows an attacker to encode their URL to bypass the url_regex check, and gain access to the blocked resource.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4001 of demo-sdc-sdc-onboarding-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP VNFSDK through Dublin. By accessing port 8000 of demo-vnfsdk-vnfsdk, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7000 of demo-sdc-sdc-wfd-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
In ONAP SO through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
An issue was discovered in ONAP SDC through Dublin. By accessing port 6000 of demo-sdc-sdc-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in upgrade_htmls.cgi on VStarcam 100T (C7824WIP) KR75.8.53.20 and 200V (C38S) KR203.18.1.20 devices. The web service, network, and account files can be manipulated through a web UI firmware update without any authentication. The attacker can achieve access to the device through a manipulated web UI firmware update.
In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
SmarterTools SmarterMail versions prior to build 9511 contain an unauthenticated remote code execution vulnerability in the ConnectToHub API method. The attacker could point the SmarterMail to the malicious HTTP server, which serves the malicious OS command. This command will be executed by the vulnerable application.
Anviz access control devices allow remote attackers to issue commands without a password.
In ONAP OOM through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A firmware update vulnerability exists in the login.cgi functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary firmware update. An attacker can send an unauthenticated message to trigger this vulnerability.
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
Bambuddy is a self-hosted print archive and management system for Bambu Lab 3D printers. Prior to version 0.1.7, a hardcoded secret key used for signing JWTs is checked into source code and ManyAPI routes do not check authentication. This issue has been patched in version 0.1.7.
Authentication for ZLAN5143D can be bypassed by directly accessing internal URLs.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. A path traversal vulnerability in FUXA allows an unauthenticated, remote attacker to write arbitrary files to arbitrary locations on the server filesystem. This affects FUXA through version 1.2.9. This issue has been patched in FUXA version 1.2.10.
Milvus is an open-source vector database built for generative AI applications. Prior to 2.5.27 and 2.6.10, Milvus exposes TCP port 9091 by default, which enables authentication bypasses. The /expr debug endpoint uses a weak, predictable default authentication token derived from etcd.rootPath (default: by-dev), enabling arbitrary expression evaluation. The full REST API (/api/v1/*) is registered on the metrics/management port without any authentication, allowing unauthenticated access to all business operations including data manipulation and credential management. This vulnerability is fixed in 2.5.27 and 2.6.10.
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. From 1.2.8 through 1.2.10, an authentication bypass vulnerability in FUXA allows an unauthenticated, remote attacker to execute arbitrary code on the server when the Node-RED plugin is enabled. This has been patched in FUXA version 1.2.11.
In JetBrains Hub before 2025.3.119807 authentication bypass allowing administrative actions was possible
An unprotected API endpoint allows an attacker to remotely change the device password without providing authentication.
Arcane is an interface for managing Docker containers, images, networks, and volumes. Prior to version 1.13.2, unauthenticated requests could be proxied to remote environment agents, allowing access to remote environment resources without authentication. The environment proxy middleware handled `/api/environments/{id}/...` requests for remote environments before authentication was enforced. When the environment ID was not local, the middleware proxied the request and attached the manager-held agent token, even if the caller was unauthenticated. This enabled unauthenticated access to remote environment operations (e.g., listing containers, streaming logs, or other agent endpoints). An unauthenticated attacker could access and manipulate remote environment resources via the proxy, potentially leading to data exposure, unauthorized changes, or service disruption. Version 1.13.2 patches the vulnerability.
METIS DFS devices (versions <= oscore 2.1.234-r18) expose a web-based shell at the /console endpoint that does not require authentication. Accessing this endpoint allows a remote attacker to execute arbitrary operating system commands with 'daemon' privileges. This results in the compromise of the software, granting unauthorized access to modify configuration, read and alter sensitive data, or disrupt services.