In Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100, ports 30001/TCP to 30003/TCP listen for arbitrary URScript code and execute the code. This enables a remote attacker who has access to the ports to remotely execute code that may allow root access to be obtained.
BMC Track-It! 11.3.0.355 does not require authentication on TCP port 9010, which allows remote attackers to upload arbitrary files, execute arbitrary code, or obtain sensitive credential and configuration information via a .NET Remoting request to (1) FileStorageService or (2) ConfigurationService.
BSS Continuity CMS 4.2.22640.0 has an Authentication Bypass vulnerability
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed.
HGiga EIP product lacks ineffective access control in certain pages that allow attackers to access database or perform privileged functions.
A vulnerability exists allowing attackers, when present in the same network segment as ClearPass' management interface, to make changes to certain databases in ClearPass by crafting HTTP packets. As a result of this attack, a possible complete cluster compromise might occur. Resolution: Fixed in 6.7.13, 6.8.4, 6.9.0 and higher.
A vulnerability in the Policy Builder interface of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to access the Policy Builder interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by accessing the Policy Builder interface. A successful exploit could allow the attacker to make changes to existing repositories and create new repositories. Cisco Bug IDs: CSCvi35109.
A vulnerability in the Redis implementation used by the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software could allow an unauthenticated, remote attacker to modify key-value pairs for short-lived events stored by the Redis server. The vulnerability is due to improper authentication when accessing the Redis server. An unauthenticated attacker could exploit this vulnerability by modifying key-value pairs stored within the Redis server database. An exploit could allow the attacker to reduce the efficiency of the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software.
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability in the Open Systems Gateway initiative (OSGi) interface of Cisco Policy Suite before 18.1.0 could allow an unauthenticated, remote attacker to directly connect to the OSGi interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by directly connecting to the OSGi interface. An exploit could allow the attacker to access or change any files that are accessible by the OSGi process. Cisco Bug IDs: CSCvh18017.
Missing authentication for critical function in DAP-1880AC firmware version 1.21 and earlier allows a remote attacker to login to the device as an authenticated user without the access privilege via unspecified vectors.
In SapphireIMS 5.0, it is possible to create local administrator on any client without requiring any credentials by directly accessing RemoteMgmtTaskSave (Automation Tasks) feature and not having a JSESSIONID.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
Authentication Bypass vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to change or update any configuration settings, or gain administrator functionality via a crafted HTTP request parameter.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
In ILIAS through 7.10, lack of verification when changing an email address (on the Profile Page) allows remote attackers to take over accounts.
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions.
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186).
WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request.
A file write vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
PacsOne Server (PACS Server In One Box) below 7.1.1 is affected by incorrect access control, which can result in remotely gaining administrator privileges.
xlockmore 5.13 and 5.22 segfaults when using libpam-opensc and returns the underlying xsession. This allows unauthorized users access to the X session.
xlockmore 5.13 allows potential xlock bypass when FVWM switches to the same virtual desktop as a new Gaim window.
A vulnerability in the Device Manager application of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions on an affected device. The vulnerability is due to a failure in the software to perform proper authentication. An attacker could exploit this vulnerability by browsing to one of the hosted URLs in Cisco DCNM. A successful exploit could allow the attacker to interact with and use certain functions within the Cisco DCNM.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
The querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode
Unrestricted access to the log downloader functionality in EPSON EPS TSE Server 8 (21.0.11) allows an unauthenticated attacker to remotely retrieve administrative hashed credentials via the maintenance/troubleshoot.php?download=1 URI.
An improper authentication vulnerability exists in the REST API functionality of Open Automation Software OAS Platform V16.00.0121. A specially-crafted series of HTTP requests can lead to unauthenticated use of the REST API. An attacker can send a series of HTTP requests to trigger this vulnerability.
The SiteGround Security plugin for WordPress is vulnerable to authentication bypass that allows unauthenticated users to log in as administrative users due to missing identity verification on the 2FA back-up code implementation that logs users in upon success. This affects versions up to, and including, 1.2.5.
A vulnerability was found in SAP Information System 1.0 which has been rated as critical. Affected by this issue is the file /SAP_Information_System/controllers/add_admin.php. An unauthenticated attacker is able to create a new admin account for the web application with a simple POST request. Exploit details were disclosed.
https://gitee.com/mingSoft/MCMS MCMS <=5.2.5 is affected by: RCE. The impact is: execute arbitrary code (remote). The attack vector is: ${"freemarker.template.utility.Execute"?new()("calc")}. ¶¶ MCMS has a pre-auth RCE vulnerability through which allows unauthenticated attacker with network access via http to compromise MCMS. Successful attacks of this vulnerability can result in takeover of MCMS.
In SapphireIMS 5.0, it is possible to take over an account by sending a request to the Save_Password form as shown in POC. Notice that we do not require a JSESSIONID in this request and can reset any user’s password by changing the username to that user and password to base64(desired password).
An issue was discovered in Reprise RLM 14.2. Because /goform/change_password_process does not verify authentication or authorization, an unauthenticated user can change the password of any existing user. This allows an attacker to change the password of any known user, thereby preventing valid users from accessing the system and granting the attacker full access to that user's account.
An issue was discovered in the box application on HiSilicon based IPTV/H.264/H.265 video encoders. The file-upload endpoint does not enforce authentication. Attackers can send an unauthenticated HTTP request to upload a custom firmware component, possibly in conjunction with command injection, to achieve arbitrary code execution.
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
D-Link DWL-900AP+ Access Point 2.1 and 2.2 allows remote attackers to access the TFTP server without authentication and read the config.img file, which contains sensitive information such as the administrative password, the WEP encryption keys, and network configuration information.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) allows unauthenticated device administration.
An issue was discovered in CIPPlanner CIPAce 9.1 Build 2019092801. Upload.ashx allows remote attackers to execute arbitrary code by uploading and executing an ASHX file.
The Web portal of the WiFi module of VPNCrypt M10 2.6.5 allows unauthenticated users to send HTTP POST request to several critical Administrative functions such as, changing credentials of the Administrator account or connect the product to a rogue access point.