Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2022-22806

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-09 Mar, 2022 | 19:30
Updated At-03 Aug, 2024 | 03:21
Rejected At-
Credits

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:09 Mar, 2022 | 19:30
Updated At:03 Aug, 2024 | 03:21
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
SmartConnect
Versions
Affected
  • SMT Series
  • SMC Series
  • SMTL Series
  • SCL Series
  • SMX Series
Problem Types
TypeCWE IDDescription
CWECWE-294CWE-294 Authentication Bypass by Capture-replay
Type: CWE
CWE ID: CWE-294
Description: CWE-294 Authentication Bypass by Capture-replay
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2022-067-02/
x_refsource_MISC
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2022-067-02/
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2022-067-02/
x_refsource_MISC
x_transferred
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2022-067-02/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:09 Mar, 2022 | 20:15
Updated At:12 May, 2022 | 20:42

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>smt_series_1015_ups_firmware>>Versions up to 04.5(inclusive)
cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>smt_series_1015_ups>>-
cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>smc_series_1018_ups_firmware>>Versions up to 04.2(inclusive)
cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>smc_series_1018_ups>>-
cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>smtl_series_1026_ups_firmware>>Versions up to 02.9(inclusive)
cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>smtl_series_1026_ups>>-
cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1029_ups_firmware>>Versions up to 02.5(inclusive)
cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1029_ups>>-
cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1030_ups_firmware>>Versions up to 02.5(inclusive)
cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1030_ups>>-
cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1036_ups_firmware>>Versions up to 02.5(inclusive)
cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1036_ups>>-
cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1037_ups_firmware>>Versions up to 03.1(inclusive)
cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>scl_series_1037_ups>>-
cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>smx_series_1031_ups_firmware>>Versions up to 03.1(inclusive)
cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>smx_series_1031_ups>>-
cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-294Primarycybersecurity@se.com
CWE-294Secondarynvd@nist.gov
CWE ID: CWE-294
Type: Primary
Source: cybersecurity@se.com
CWE ID: CWE-294
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.se.com/ww/en/download/document/SEVD-2022-067-02/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2022-067-02/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

153Records found

CVE-2018-7820
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.28% / 51.17%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:45
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.

Action-Not Available
Vendor-
Product-ap9630ap9631ap9635smart-ups_srt_5kvaap9635_firmwareap9630_firmwaresmart-ups_srt_5kva_firmwareap9631_firmwareAPC UPS Network Management Card 2 AOS
CWE ID-CWE-255
Not Available
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-7836
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.32% / 84.15%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files.

Action-Not Available
Vendor-
Product-iiot_monitorIIoT Monitor 3.1.38
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2018-7780
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.54% / 66.73%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 00:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".

Action-Not Available
Vendor-
Product-imp519-1er_firmwareimp319-1eribp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimps110-1_firmwareibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimps110-1imp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1erimp319-1Pelco Sarix Professional V1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-26507
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.70% / 90.87%
||
7 Day CHG~0.00%
Published-14 Apr, 2022 | 12:04
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-attn/a
Product-ecostruxure_process_expertecostruxure_control_expertremoteconnectxmillscadapack_470scadapack_570scadapack_574scadapack_575scadapack_474n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-7841
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-59.14% / 98.15%
||
7 Day CHG+20.04%
Published-22 May, 2019 | 19:20
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-06||The impacted product is end-of-life and should be disconnected if still in use.

A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.

Action-Not Available
Vendor-U.motionSchneider Electric SE
Product-u.motion_builderU.motion Builder software version 1.3.4U.motion Builder
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7785
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-14.47% / 94.18%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.

Action-Not Available
Vendor-
Product-u.motion_builderU.motion Builder
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7847
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.22% / 78.28%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-287
Improper Authentication
CVE-2018-7778
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.69% / 70.93%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.

Action-Not Available
Vendor-
Product-evlink_charging_stationevlink_charging_station_firmwareEvlink Charging Station
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-22805
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-8.20% / 91.85%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-scl_series_1036_upssmc_series_1018_ups_firmwaresmtl_series_1026_upsscl_series_1029_ups_firmwaresmt_series_1015_upssmtl_series_1026_ups_firmwarescl_series_1030_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_ups_firmwaresmx_series_1031_upsscl_series_1037_ups_firmwarescl_series_1037_upsscl_series_1036_ups_firmwaresmc_series_1018_upsscl_series_1030_upsscl_series_1029_upsSmartConnect
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-22813
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.41% / 60.37%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.

Action-Not Available
Vendor-n/a
Product-easergy_p746_firmwareeasergy_p742easergy_p849easergy_p441easergy_p142_firmwareeasergy_p546easergy_p543easergy_p541easergy_p143_firmwareeasergy_p141easergy_p342easergy_p542easergy_p241_firmwareeasergy_p545_firmwareeasergy_p243_firmwareeasergy_p446easergy_p741easergy_p642easergy_p541_firmwareeasergy_p342_firmwareeasergy_p645easergy_p345_firmwareeasergy_p743easergy_p145easergy_p343_firmwareeasergy_p849_firmwareeasergy_p643_firmwareeasergy_p242_firmwareeasergy_p545easergy_p344easergy_p142easergy_p442easergy_p544easergy_p143easergy_p441_firmwareeasergy_p743_firmwareeasergy_p542_firmwareeasergy_p645_firmwareeasergy_p242easergy_p841easergy_p343easergy_p543_firmwareeasergy_p443_firmwareeasergy_p446_firmwareeasergy_p445_firmwareeasergy_p341_firmwareeasergy_p742_firmwareeasergy_p444_firmwareeasergy_p445easergy_p444easergy_p642_firmwareeasergy_p341easergy_p544_firmwareeasergy_p442_firmwareeasergy_p741_firmwareeasergy_p141_firmwareeasergy_p841_firmwareeasergy_p241easergy_p344_firmwareeasergy_p746easergy_p643easergy_p546_firmwareeasergy_p145_firmwareeasergy_p443easergy_p345easergy_p243Easergy P40 Series model numbers with Ethernet option bit as Q, R, S (All PX4X firmware Versions)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-0223
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.23% / 45.66%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-1126
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.30% / 52.96%
||
7 Day CHG~0.00%
Published-23 May, 2018 | 13:00
Updated-05 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.

Action-Not Available
Vendor-procps-ng_project[UNKNOWN]Canonical Ltd.Red Hat, Inc.Debian GNU/Linux
Product-enterprise_linux_serverubuntu_linuxdebian_linuxprocps-ngenterprise_linux_server_ausenterprise_linux_workstationenterprise_linuxenterprise_linux_server_tusenterprise_linux_desktopstruxureware_data_center_expertprocps-ng, procps
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2017-9956
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.49% / 64.37%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-9957
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.43%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-9629
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-19.42% / 95.17%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2017-7973
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 55.77%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2017-7974
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-7.80% / 91.59%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A path traversal information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can execute arbitrary code and exfiltrate files.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2017-7689
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.23% / 86.56%
||
7 Day CHG~0.00%
Published-11 Apr, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-homelynk_controller_lss100100homelynk_controller_lss100100_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-6028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.70%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m241modicon_m251modicon_m251_firmwaremodicon_m241_firmwareSchneider Electric Modicon PLCs
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.38% / 58.48%
||
7 Day CHG+0.16%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-32524
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.60%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32520
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.16% / 37.69%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32513
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 40.20%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-521
Weak Password Requirements
CVE-2022-32529
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.60%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32522
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.78% / 87.61%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32518
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.16% / 37.69%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2024-2051
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.02%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 16:03
Updated-28 Aug, 2024 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover and unauthorized access to the system when an attacker conducts brute-force attacks against the login form.

Action-Not Available
Vendor-
Product-Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200HEasergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200Heasergy_t200h_firmwareeasergy_t200p_firmwareeasergy_t200i_firmwareeasergy_t200s_firmwareeasergy_t200e_firmware
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2022-37300
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 51.86%
||
7 Day CHG~0.00%
Published-12 Sep, 2022 | 17:40
Updated-03 Aug, 2024 | 10:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).

Action-Not Available
Vendor-
Product-modicon_m340_bmxp342030_firmwaremodicon_m340_bmxp3420302h_firmwaremodicon_m340_bmxp342020h_firmwaremodicon_m580_bmep583040_firmwaremodicon_m580_bmeh582040smodicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010modicon_m580_bmeh584040smodicon_m580_bmep582020h_firmwaremodicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep582040h_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmeh584040modicon_m580_bmep585040modicon_m580_bmep585040c_firmwaremodicon_m580_bmeh584040_firmwaremodicon_m580_bmep581020h_firmwaremodicon_m580_bmep584020modicon_m580_bmeh584040s_firmwaremodicon_m340_bmxp342020modicon_m340_bmxp342030hmodicon_m340_bmxp342020hmodicon_m580_bmeh586040cmodicon_m580_bmep582020_firmwaremodicon_m340_bmxp342000_firmwaremodicon_m580_bmeh586040_firmwaremodicon_m580_bmep581020hmodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_m580_bmeh586040c_firmwaremodicon_m580_bmep586040_firmwaremodicon_m580_bmeh582040_firmwaremodicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_m580_bmeh582040c_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_m340_bmxp342000modicon_m580_bmeh586040modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp341000modicon_m580_bmeh584040c_firmwaremodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep582040hmodicon_m340_bmxp3420302modicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwareecostruxure_process_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_m340_bmxp342030h_firmwaremodicon_m580_bmep582020hmodicon_m580_bmep586040c_firmwaremodicon_m340_bmxp3420102modicon_m580_bmeh582040s_firmwareEcoStruxure Control ExpertEcoStruxure Process ExpertModicon M340 CPUModicon M580 CPU
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2022-32526
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.61% / 87.32%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-7475
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 67.66%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 18:56
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertmodicon_m580_firmwareunity_promodicon_m340modicon_m340_firmwaremodicon_m580EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.82%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7540
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.31% / 53.66%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwarebmxnor200h_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnor200htsxp576634_firmwarebmxnoc0401modicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7533
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.24% / 46.20%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:47
Updated-10 Jun, 2025 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-140noc78000tsxp574634_firmwaretsxp574634140cpu65260_firmwaretsxety4103tsxp575634modicon_m340_bmxp342000modicon_m340_bmxp3420302_firmwarebmxnoe0100modicon_m340_bmxp342000_firmwarebmxnoe0110_firmwaretsxety5103_firmwaretsxp576634140noe77111_firmwaremodicon_m340_bmxp341000modicon_m340_bmxp3420102_firmwaremodicon_m340_bmxp341000_firmwarebmxnoe0110tsxp575634_firmware140noe77111bmxnoe0100_firmwarebmxnoc0401_firmware140noc77101140cpu65260bmxnoc0401140noc77101_firmwaretsxety4103_firmwaremodicon_m340_bmxp3420302140noc78000_firmwaretsxp576634_firmwaremodicon_m340_bmxp3420102tsxety5103Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see security notification for version information)
CWE ID-CWE-287
Improper Authentication
CVE-2022-32515
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.16% / 36.91%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-conext_comboxconext_combox_firmwareConext™ ComBox
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2024-38438
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
ShareView Details
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
CVSS Score-9.8||CRITICAL
EPSS-0.68% / 70.68%
||
7 Day CHG~0.00%
Published-21 Jul, 2024 | 07:19
Updated-29 Aug, 2024 | 22:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link - CWE-294: Authentication Bypass by Capture-replay

D-Link - CWE-294: Authentication Bypass by Capture-replay

Action-Not Available
Vendor-D-Link Corporation
Product-dsl-225dsl-225_firmwareDSL-225dsl-225_firmware
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-23397
Matching Score-4
Assigner-Microsoft Corporation
ShareView Details
Matching Score-4
Assigner-Microsoft Corporation
CVSS Score-9.8||CRITICAL
EPSS-93.58% / 99.83%
||
7 Day CHG-0.09%
Published-14 Mar, 2023 | 16:55
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2023-04-04||Apply updates per vendor instructions.
Microsoft Outlook Elevation of Privilege Vulnerability

Microsoft Outlook Elevation of Privilege Vulnerability

Action-Not Available
Vendor-Microsoft Corporation
Product-office_long_term_servicing_channel365_appsoutlookofficeMicrosoft Office 2019Microsoft Office LTSC 2021Microsoft Outlook 2013 Service Pack 1Microsoft 365 Apps for EnterpriseMicrosoft Outlook 2016Office
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-1886
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-7.3||HIGH
EPSS-0.28% / 50.81%
||
7 Day CHG~0.00%
Published-05 Apr, 2023 | 00:00
Updated-10 Feb, 2025 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authentication Bypass by Capture-replay in thorsten/phpmyfaq

Authentication Bypass by Capture-replay in GitHub repository thorsten/phpmyfaq prior to 3.1.12.

Action-Not Available
Vendor-Thorsten Rinne (phpMyFAQ)
Product-phpmyfaqthorsten/phpmyfaq
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-1537
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 13.61%
||
7 Day CHG~0.00%
Published-21 Mar, 2023 | 00:00
Updated-27 Feb, 2025 | 16:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authentication Bypass by Capture-replay in answerdev/answer

Authentication Bypass by Capture-replay in GitHub repository answerdev/answer prior to 1.0.6.

Action-Not Available
Vendor-answeranswerdev
Product-answeranswerdev/answer
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-44457
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 51.92%
||
7 Day CHG~0.00%
Published-08 Nov, 2022 | 00:00
Updated-01 May, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML (Mendix 7 compatible)Mendix SAML (Mendix 9 compatible, New Track)Mendix SAML (Mendix 8 compatible)Mendix SAML (Mendix 9 compatible, Upgrade Track)
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-37011
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.03% / 7.27%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 00:00
Updated-03 Aug, 2024 | 10:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0). Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML (Mendix 9 compatible, New Track)Mendix SAML (Mendix 7 compatible)Mendix SAML (Mendix 9 compatible, Upgrade Track)Mendix SAML (Mendix 8 compatible)
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-0014
Matching Score-4
Assigner-SAP SE
ShareView Details
Matching Score-4
Assigner-SAP SE
CVSS Score-9||CRITICAL
EPSS-0.24% / 46.43%
||
7 Day CHG~0.00%
Published-10 Jan, 2023 | 03:02
Updated-09 Apr, 2025 | 13:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Capture-replay vulnerability in SAP NetWeaver AS for ABAP and ABAP Platform

SAP NetWeaver ABAP Server and ABAP Platform - versions SAP_BASIS 700, 701, 702, 710, 711, 730, 731, 740, 750, 751, 752, 753, 754, 755, 756, 757, KERNEL 7.22, 7.53, 7.77, 7.81, 7.85, 7.89, KRNL64UC 7.22, 7.22EXT, 7.53, KRNL64NUC 7.22, 7.22EXT, creates information about system identity in an ambiguous format. This could lead to capture-replay vulnerability and may be exploited by malicious users to obtain illegitimate access to the system.

Action-Not Available
Vendor-SAP SE
Product-netweaver_application_server_abap_krnl64nucnetweaver_application_server_abap_krnl64ucnetweaver_application_server_abap_kernelnetweaver_application_server_abapNetWeaver ABAP Server and ABAP Platform
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2021-38459
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.22% / 44.80%
||
7 Day CHG~0.00%
Published-22 Oct, 2021 | 11:23
Updated-16 Sep, 2024 | 21:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
AUVESY Versiondog

The data of a network capture of the initial handshake phase can be used to authenticate at a SYSDBA level. If a specific .exe is not restarted often, it is possible to access the needed handshake packets between admin/client connections. Using the SYSDBA permission, an attacker can change user passwords or delete the database.

Action-Not Available
Vendor-auvesyAUVESY
Product-versiondogVersiondog
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-49231
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.83% / 73.65%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-28 Oct, 2024 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authentication bypass vulnerability was found in Stilog Visual Planning 8. It allows an unauthenticated attacker to receive an administrative API token.

Action-Not Available
Vendor-n/astilog
Product-n/avisual__planning_8
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-29334
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.32% / 54.08%
||
7 Day CHG~0.00%
Published-24 May, 2022 | 21:05
Updated-03 Aug, 2024 | 06:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in H v1.0 allows attackers to bypass authentication via a session replay attack.

Action-Not Available
Vendor-h_projectn/a
Product-hn/a
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-47435
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.06% / 18.99%
||
7 Day CHG~0.00%
Published-19 Apr, 2024 | 00:00
Updated-02 Aug, 2024 | 21:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in the verifyPassword function of hexo-theme-matery v2.0.0 allows attackers to bypass authentication and access password protected pages.

Action-Not Available
Vendor-n/ahexo
Product-n/ahexo_themes
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2021-22640
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.23% / 45.41%
||
7 Day CHG~0.00%
Published-28 Jul, 2022 | 14:18
Updated-17 Apr, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ovarro TBox Insufficiently Protected Credentials

An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks.

Action-Not Available
Vendor-ovarroOvarro
Product-tbox_ms-cpu32_firmwaretbox_ms-cpu32-s2_firmwaretbox_tg2tbox_lt2-530_firmwaretbox_lt2-532_firmwaretbox_lt2-540_firmwaretbox_rm2tbox_ms-cpu32-s2tbox_lt2-540tbox_lt2-532tbox_lt2-530tbox_ms-cpu32twinsofttbox_tg2_firmwaretbox_rm2_firmwareTBox
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2002-0054
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-8.24% / 91.87%
||
7 Day CHG~0.00%
Published-02 Apr, 2003 | 05:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SMTP service in (1) Microsoft Windows 2000 and (2) Internet Mail Connector (IMC) in Exchange Server 5.5 does not properly handle responses to NTLM authentication, which allows remote attackers to perform mail relaying via an SMTP AUTH command using null session credentials.

Action-Not Available
Vendor-n/aMicrosoft Corporation
Product-exchange_serverwindows_2000n/a
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2019-18226
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 39.64%
||
7 Day CHG~0.00%
Published-31 Oct, 2019 | 21:21
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.

Action-Not Available
Vendor-n/aHoneywell International Inc.
Product-hbw4pgr1_firmwareh3w4gr1_firmwarehew2per3h2w4per3_firmwarehm4l8gr1h3w2gr2hbd2per1hcw4g_firmwareh4w2per2_firmwareh2w2gr1_firmwarehed2per3_firmwarehdzp304di_firmwarehdzp252dihew2per2_firmwareh4w4gr1vh4w4gr1hsw2g1hdz302dehbl6gr2h2w2pc1mhew4per3hfd6gr1_firmwarehbd2per1_firmwarehcw4gh3w4gr1vh3w2gr1hbw4gr1vh3w4gr1v_firmwarehdz302dhbw2per2_firmwareh4w2gr1_firmwarehdzp304dih4w2gr2hew2per3_firmwarehew4per2b_firmwarehbw8pr2hdz302likhmbl8gr1_firmwarehdzp252di_firmwareh4l2gr1hcd8gh4w8pr2h4l2gr1v_firmwareh2w2pc1m_firmwareh4w2gr1v_firmwareh4w2gr1vh4w4per3hbd8gr1hdz302din-c1hpw2p1_firmwarehbw2gr1vhdz302din-s1hbw2gr1v_firmwareh3w2gr1_firmwarehbw2gr3v_firmwareh4w4gr1_firmwarehfd8gr1hdz302liw_firmwarehcl2g_firmwareh4d8gr1_firmwarehcl2ghbw4per1_firmwareh4w2per3_firmwareh4w4per2_firmwarehcd8g_firmwarehdz302din-s1_firmwareh2w2per3hcw2g_firmwareh3w4gr1hew2per2hew4per3bh4l6gr2hmbl8gr1hew4per2bh3w2gr1v_firmwareh4w4per3_firmwarehew4per3b_firmwarehepz302w0hepz302w0_firmwareh3w2gr2_firmwareh4l2gr1vhbw2per1h4l6gr2_firmwarehdz302liwhdz302lik_firmwarehdz302de_firmwareh2w2gr1hcw2gvhbl2gr1vhbw2per1_firmwarehswb2g1hbd8gr1_firmwareh4w4gr1v_firmwarehbl6gr2_firmwarehswb2g1_firmwarehfd6gr1hbw2per2hcw2gh4w8pr2_firmwarehdz302d_firmwarehcw2gv_firmwareh2w4per3h4w2gr2_firmwarehm4l8gr1_firmwareh4d8gr1hed2per3h4w2gr1h2w2per3_firmwarehbw8pr2_firmwareh3w2gr1vhbw4per2_firmwareh4w4per2hbw2gr3vh4w2per3hbw4pgr1h4l2gr1_firmwarehcl2gv_firmwarehfd8gr1_firmwarehsw2g1_firmwarehbw4gr1v_firmwarehbw4per1hdz302din-c1_firmwarehbl2gr1v_firmwarehcl2gvhew4per3_firmwarehpw2p1hbw4per2h4w2per2Honeywell equIP series cameras, Honeywell Performance series IP cameras, Honeywell recorders
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-30909
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-4.96% / 89.25%
||
7 Day CHG~0.00%
Published-14 Sep, 2023 | 14:56
Updated-28 Oct, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote authentication bypass issue exists in some OneView APIs.

Action-Not Available
Vendor-HP Inc.Hewlett Packard Enterprise (HPE)
Product-oneviewHPE OneViewoneview_global_dashboardoneview
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2018-19025
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.24% / 46.23%
||
7 Day CHG~0.00%
Published-02 Nov, 2020 | 16:48
Updated-05 Aug, 2024 | 11:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In JUUKO K-808, an attacker could specially craft a packet that encodes an arbitrary command, which could be executed on the K-808 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.).

Action-Not Available
Vendor-juukon/a
Product-k-808_firmwarek-808JUUKO K-808
CWE ID-CWE-294
Authentication Bypass by Capture-replay
  • Previous
  • 1
  • 2
  • 3
  • 4
  • Next
Details not found