Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-6407

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-11 Jul, 2024 | 09:07
Updated At-01 Aug, 2024 | 21:41
Rejected At-
Credits

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:11 Jul, 2024 | 09:07
Updated At:01 Aug, 2024 | 21:41
Rejected At:
▼CVE Numbering Authority (CNA)

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
Wiser Home Controller WHC-5918A
Default Status
unaffected
Versions
Affected
  • All Versions of Wiser Home Controller WHC-5918A
Problem Types
TypeCWE IDDescription
CWECWE-200CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
Type: CWE
CWE ID: CWE-200
Description: CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
Metrics
VersionBase scoreBase severityVector
3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-01.pdf
N/A
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-01.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-01.pdf
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-01.pdf
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:11 Jul, 2024 | 10:15
Updated At:12 Jul, 2024 | 16:36

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Secondary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Type: Secondary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Schneider Electric SE
schneider-electric
>>whc-5918a_firmware>>*
cpe:2.3:o:schneider-electric:whc-5918a_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>whc-5918a>>-
cpe:2.3:h:schneider-electric:whc-5918a:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-noinfoPrimarynvd@nist.gov
CWE-200Secondarycybersecurity@se.com
CWE ID: NVD-CWE-noinfo
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-200
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-01.pdfcybersecurity@se.com
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-01.pdf
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1086Records found

CVE-2021-22737
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.30% / 53.11%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 00:00
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2021-22798
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.29% / 52.07%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)

Action-Not Available
Vendor-n/a
Product-conext_comboxconext_combox_firmwareConext� ComBox (All Versions)
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2021-22795
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-3.19% / 86.47%
||
7 Day CHG~0.00%
Published-28 Mar, 2022 | 16:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-22774
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.06%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:45
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get knowledge of charging station user account credentials using dictionary attacks techniques.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-916
Use of Password Hash With Insufficient Computational Effort
CVE-2021-22703
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.16% / 37.33%
||
7 Day CHG~0.00%
Published-19 Feb, 2021 | 15:14
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion8650powerlogic_ion8400_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion8300_firmwarepowerlogic_ion7400_firmwarepowerlogic_ion7650_firmwarepowerlogic_ion8800powerlogic_ion8600powerlogic_ion8500_firmwarepowerlogic_ion8300powerlogic_ion8500powerlogic_ion8600_firmwarepowerlogic_ion9000_firmwarepowerlogic_ion9000powerlogic_ion8400powerlogic_ion8800_firmwarepowerlogic_ion7400powerlogic_ion7650powerlogic_ion8650_firmwarePowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2021-22801
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.84% / 73.84%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)

Action-Not Available
Vendor-n/a
Product-connexium_network_managerConneXium Network Manager Software (All Versions)
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-22802
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-7.12% / 91.17%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-22731
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.01% / 82.94%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.

Action-Not Available
Vendor-n/a
Product-mcsesm083f23f0hmcsesp083f23g0t_firmwaremcsesm083f23f0_firmwaremcsesp083f23g0tmcsesm063f2cu0mcsesm063f2cs0_firmwaremcsesm103f2cu0mcsesm123f2lg0mcsesp083f23g0_firmwaremcsesm103f2cu0hmcsesm053f1cu0_firmwaremcsesm103f2cs0hmcsesm093f1cu0_firmwaremcsesm093f1cu0mcsesm043f23f0_firmwaremcsesm093f1cs0_firmwaremcsesm053f1cu0mcsesm043f23f0mcsesm103f2cs0_firmwaremcsesm103f2cs0h_firmwaremcsesm083f23f0h_firmwaremcsesm083f23f0mcsesm063f2cu0_firmwaremcsesm123f2lg0_firmwaremcsesm053f1cs0_firmwaremcsesp083f23g0mcsesm063f2cs0mcsesm103f2cu0_firmwaremcsesm103f2cu0h_firmwaremcsesm093f1cs0mcsesm103f2cs0mcsesm053f1cs0Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2017-7689
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.23% / 86.55%
||
7 Day CHG~0.00%
Published-11 Apr, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-homelynk_controller_lss100100homelynk_controller_lss100100_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-22763
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.25% / 47.85%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-24 Nov, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.

Action-Not Available
Vendor-n/a
Product-powerlogic_pm5561powerlogic_pm5560_firmwarepowerlogic_pm8ecc_firmwarepowerlogic_pm5562_firmwarepowerlogic_pm8eccpowerlogic_pm5561_firmwarepowerlogic_pm5563powerlogic_pm5563_firmwarepowerlogic_pm5562powerlogic_pm5560PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation)
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2021-22806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.39% / 58.87%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
CVE-2021-22804
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.49% / 64.55%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22714
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.27% / 83.98%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:13
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion9000_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion9000powerlogic_ion7400_firmwarepowerlogic_ion7400PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2017-9629
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-19.42% / 95.16%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1960
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.08% / 25.32%
||
7 Day CHG+0.01%
Published-12 Mar, 2025 | 15:33
Updated-13 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.

Action-Not Available
Vendor-Schneider Electric SE
Product-WebHMI – Deployed with EcoStruxure Power Automation System
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2025-1060
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.04% / 9.74%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 05:53
Updated-13 Feb, 2025 | 15:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure of data when network traffic is being sniffed by an attacker.

Action-Not Available
Vendor-Schneider Electric SE
Product-ASCO 5350 Eight Channel Remote AnnunciatorASCO 5310 Single-Channel Remote Annunciator
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2017-7574
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.18%
||
7 Day CHG~0.00%
Published-06 Apr, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_tm221ce16r_firmwaresomachinemodicon_tm221ce16rn/a
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-11737
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.3||CRITICAL
EPSS-0.31% / 53.76%
||
7 Day CHG~0.00%
Published-11 Dec, 2024 | 09:36
Updated-11 Dec, 2024 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of confidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device.

Action-Not Available
Vendor-
Product-Modicon Controllers M241 / M251Modicon Controllers M258 / LMC058
CWE ID-CWE-20
Improper Input Validation
CVE-2017-6028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.71%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m241modicon_m251modicon_m251_firmwaremodicon_m241_firmwareSchneider Electric Modicon PLCs
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-34756
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.87% / 82.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2022 | 21:10
Updated-17 Sep, 2024 | 04:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)

Action-Not Available
Vendor-
Product-easergy_p5_firmwareeasergy_p5Easergy P5
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32529
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.59%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32519
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.19% / 41.34%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32514
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.20% / 41.74%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-287
Improper Authentication
CVE-2022-32513
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 40.22%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-521
Weak Password Requirements
CVE-2022-32524
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.59%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32518
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.16% / 37.70%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32526
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.61% / 87.32%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-7497
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.49% / 80.24%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:13
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.

Action-Not Available
Vendor-n/a
Product-ecostruxure_operator_terminal_expertEcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-32527
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.61% / 87.32%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32520
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.16% / 37.70%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2020-7485
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.53%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 21:03
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy support account in the TriStation software version v4.9.0 and earlier could cause improper access to the TriStation host machine. This was addressed in TriStation version v4.9.1 and v4.10.1 released on May 30, 2013.1

Action-Not Available
Vendor-n/aMicrosoft Corporation
Product-windows_7windows_xpwindows_nttristation_1131TriStation TS1131 (v4.0.0 to v4.9.0, v4.10.0)
CVE-2022-32523
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.59%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32522
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.78% / 87.61%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-7512
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 61.79%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-1103
Use of Platform-Dependent Third Party Components
CVE-2022-32525
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.61% / 87.32%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-7489
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.47% / 63.71%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:15
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_m200modicon_m100_firmwaremodicon_m221ecostruxure_machine_expertmodicon_m200_firmwaresomachine_basicmodicon_m221_firmwaremodicon_m100SoMachine Basic (all versions)EcoStruxure Machine Expert – Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7483
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.09% / 26.63%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 21:03
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause certain data to be visible on the network when the 'password' feature is enabled. This vulnerability was discovered in and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. The 'password' feature is an additional optional check performed by TS1131 that it is connected to a specific controller. This data is sent as clear text and is visible on the network. This feature is not present in TriStation 1131 versions v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions.

Action-Not Available
Vendor-n/aMicrosoft Corporation
Product-windows_7windows_xpwindows_nttristation_1131TriStation TS1131 (v4.0.0 to v4.9.0, v4.10.0)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2020-7525
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.99% / 75.96%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:12
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used.

Action-Not Available
Vendor-n/a
Product-wiser_for_knx_firmwarespacelynk_firmwarewiser_for_knxspacelynkAll hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk)
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2020-7535
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.43% / 61.61%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of information when sending a specially crafted request to the controller over HTTP.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwaretsxp576634_firmwaremodicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7561
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.59% / 80.88%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 00:00
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 with firmware 2.7 and older
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7513
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.15% / 36.25%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to intercept traffic and read configuration data.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2020-7540
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.31% / 53.66%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwarebmxnor200h_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnor200htsxp576634_firmwarebmxnoc0401modicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7475
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 67.64%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 18:56
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertmodicon_m580_firmwareunity_promodicon_m340modicon_m340_firmwaremodicon_m580EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7488
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.19% / 40.82%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.

Action-Not Available
Vendor-n/a
Product-modicon_m241_firmwaremodicon_m218ecostruxure_machine_expertsomachine_motionmodicon_m218_firmwaremodicon_m241somachinemodicon_m258modicon_m258_firmwaremodicon_m251_firmwaremodicon_m251EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2020-7478
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-1.85% / 82.24%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:17
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7491
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.25% / 47.96%
||
7 Day CHG~0.00%
Published-23 Jul, 2020 | 20:46
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4.

Action-Not Available
Vendor-n/a
Product-tricon_tcm_4352tristation_1131_firmwaretricon_tcm_4352atricon_tcm_4351btricon_tcm_4351a_firmwaretricon_tcm_4351_firmwaretricon_tcm_4352btricon_tcm_4352b_firmwaretristation_1131tricon_tcm_4352_firmwaretricon_tcm_4351b_firmwaretricon_tcm_4351atricon_tcm_4352a_firmwaretricon_tcm_4351Tricon system versions 10.2.0 through 10.5.3
CVE-2020-7480
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 67.64%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:24
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.

Action-Not Available
Vendor-n/a
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum (All versions)
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-29411
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-5.99% / 90.32%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:49
Updated-05 Feb, 2025 | 21:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-25550
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-2.76% / 85.43%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:36
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2020-7519
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.64%
||
7 Day CHG~0.00%
Published-23 Jul, 2020 | 20:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.

Action-Not Available
Vendor-n/a
Product-easergy_builderEasergy Builder (Version 1.4.7.2 and older)
CWE ID-CWE-521
Weak Password Requirements
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 21
  • 22
  • Next
Details not found