A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover and unauthorized access to the system when an attacker conducts brute-force attacks against the login form.
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local function call.
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP.
CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the confcli binary.
open5gs v2.6.4 is vulnerable to Buffer Overflow. via /lib/core/abts.c.
D-Link DIR-868L Hardware version A1, firmware version 1.12 is vulnerable to Buffer Overflow. The vulnerability is in scandir.sgi binary.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the mesh_status_check binary.
Buffer overflow vulnerability in function NumberToPrecisionCmd in jsish before 3.0.7, allows remote attackers to execute arbitrary code.
Sofia-SIP is an open-source SIP User-Agent library, compliant with the IETF RFC3261 specification. In affected versions Sofia-SIP **lacks both message length and attributes length checks** when it handles STUN packets, leading to controllable heap-over-flow. For example, in stun_parse_attribute(), after we get the attribute's type and length value, the length will be used directly to copy from the heap, regardless of the message's left size. Since network users control the overflowed length, and the data is written to heap chunks later, attackers may achieve remote code execution by heap grooming or other exploitation methods. The bug was introduced 16 years ago in sofia-sip 1.12.4 (plus some patches through 12/21/2006) to in tree libs with git-svn-id: http://svn.freeswitch.org/svn/freeswitch/trunk@3774 d0543943-73ff-0310-b7d9-9358b9ac24b2. Users are advised to upgrade. There are no known workarounds for this vulnerability.
xrdp is an open source project which provides a graphical login to remote machines using Microsoft Remote Desktop Protocol (RDP). xrdp < v0.9.21 contain a buffer over flow in audin_send_open() function. There are no known workarounds for this issue. Users are advised to upgrade.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the pppd binary.
TOTOLINK A3700R v9.1.2u.5822_B20200513 has a buffer overflow vulnerability in the ssid parameter in setWizardCfg function.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the multiWAN binary.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the logserver binary.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the libcommonprod.so binary.
Open Robotics Robotic Operating System 2 (ROS2) and Nav2 humble version was discovered to contain a heap overflow in the nav2_amcl process. This vulnerability is triggered via sending a crafted message to the component /initialpose.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the rtk_ate binary.
Buffer Overflow vulnerability found in Netgear R6900 v.1.0.2.26, R6700v3 v.1.0.4.128, R6700 v.1.0.0.26 allows a remote attacker to execute arbitrary code and cause a denial ofservice via the getInputData parameter of the fwSchedule.cgi page.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 has a buffer overflow vulnerability in the password parameter in the loginauth function.
miniupnp before 4c90b87, as used in Bitcoin Core before 0.12 and other products, lacks checks for snprintf return values, leading to a buffer overflow and significant data leak, a different vulnerability than CVE-2019-12107. In Bitcoin Core before 0.12, remote code execution was possible in conjunction with CVE-2015-6031 exploitation.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the ap_steer binary.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the netctrl binary.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the sntp binary.
xrdp is an open source project which provides a graphical login to remote machines using Microsoft Remote Desktop Protocol (RDP). xrdp < v0.9.21 contain a buffer over flow in xrdp_login_wnd_create() function. There are no known workarounds for this issue. Users are advised to upgrade.
In the Linux kernel, the following vulnerability has been resolved: of: module: add buffer overflow check in of_modalias() In of_modalias(), if the buffer happens to be too small even for the 1st snprintf() call, the len parameter will become negative and str parameter (if not NULL initially) will point beyond the buffer's end. Add the buffer overflow check after the 1st snprintf() call and fix such check after the strlen() call (accounting for the terminating NUL char).
In TRENDnet TEW-752DRU FW1.03B01, there is a buffer overflow vulnerability due to the lack of length verification for the service field in gena.cgi. Attackers who successfully exploit this vulnerability can cause the remote target device to crash or execute arbitrary commands.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the network_check binary.
The Texas Instruments (TI) WiLink WL18xx MCP driver does not limit the number of information elements (IEs) of type XCC_EXT_1_IE_ID or XCC_EXT_2_IE_ID that can be parsed in a management frame. Using a specially crafted frame, a buffer overflow can be triggered that can potentially lead to remote code execution. This affects WILINK8-WIFI-MCP8 version 8.5_SP3 and earlier.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the online_process binary.